Development of a deformable lung phantom for the evaluation of deformable registration

被引:38
|
作者
Chang, Jina [1 ]
Suh, Tae-Suk [1 ]
Lee, Dong-Soo [2 ]
机构
[1] Catholic Univ, Coll Med, Dept Biomed Engn, Seoul 137701, South Korea
[2] Seoul Natl Univ Hosp, Dept Nucl Med, Seoul 137701, South Korea
来源
关键词
deformable lung phantom; deformable registration; evaluation; IMAGE REGISTRATION; RADIATION-THERAPY; TECHNICAL NOTE; CT; MOTION; RADIOTHERAPY;
D O I
10.1120/jacmp.v11i1.3081
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A deformable lung phantom was developed to simulate patient breathing motion and to evaluate a deformable image registration algorithm. The phantom consisted of an acryl cylinder filled with water and a latex balloon located in the inner space of the cylinder. A silicon membrane was attached to the inferior end of the phantom. The silicon membrane was designed to simulate a real lung diaphragm and to reduce motor workload. This specific design was able to reduce the use of metal, which may prevent infrared sensing of the real position management (RPM) gating system for four-dimensional (4D) CT image acquisition. Verification of intensity based three-dimensional (3D) demons deformable registration was based on the peak exhale and peak inhale breathing phases. The registration differences ranged from 0.60 mm to 1.11 mm and accuracy was determined according to inner target deformation. The phantom was able to simulate features and deformation of a real human lung and has the potential for wide application for 4D radiation treatment planning.
引用
收藏
页码:281 / 286
页数:6
相关论文
共 50 条
  • [1] Development of a Deformable Lung Phantom for the Evaluation of Deformable Registration
    Chang, J.
    Lee, D.
    Suh, T.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 635 - 637
  • [2] Development of a Deformable Lung Phantom for the Evaluation of Deformable Registration
    Chang, J.
    Suh, T.
    Lee, D.
    Cho, G.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [3] Development of An Anthropomorphic Deformable Lung Phantom
    Shin, D.
    Kang, S.
    Kim, K.
    Kim, T.
    Kim, D.
    Yoon, D.
    Yamamoto, T.
    Suh, T.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3300 - 3300
  • [4] Development of a dynamic deformable thorax phantom for the quality management of deformable image registration
    Sugawara, Yasuharu
    Kadoya, Noriyuki
    Kotabe, Kazuki
    Nakajima, Yujiro
    Ikeda, Ryutaro
    Tanabe, Shunpei
    Ohashi, Haruna
    Jingu, Keiichi
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 77 : 100 - 107
  • [5] Evaluation of the accuracy of deformable image registration on MRI with a physical phantom
    Wu, Richard Y.
    Liu, Amy Y.
    Yang, Jinzhong
    Williamson, Tyler D.
    Wisdom, Paul G.
    Bronk, Lawrence
    Gao, Song
    Grosshan, David R.
    Fuller, David C.
    Gunn, Gary B.
    Ronald Zhu, X.
    Frank, Steven J.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (01): : 166 - 173
  • [6] Comparison of two deformable registration software using an in-house "deformable phantom"
    Koutsouvelis, N.
    Rouzaud, M.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (11) : 838 - 839
  • [7] An Anthropopathic Deformable Phantom for Geometric and Dose Accumulation Accuracy Validation of Deformable Image Registration
    Liao, Y.
    Chen, H.
    Chen, J.
    Gu, X.
    Zhen, X.
    Zhou, L.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3884 - 3884
  • [8] A Three-Dimensional Thermoplastic Prostate Phantom for Evaluation of Deformable Image Registration
    Reber, C.
    Neo, A.
    Schoenhoff, E.
    Kirby, N.
    Singhrao, K.
    Pouliot, J.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [9] Evaluation of Diffeomorphic Demons Algorithm for Deformable Image Registration Using Virtual Phantom
    Reiazi, R.
    Mohammadi, R.
    Mahdavi, S. R.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E228 - E228
  • [10] Intra and Intermodality Validation of Registration Algorithms On a Deformable Phantom
    Vincent, S. D.
    Archambault, L.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)