Development of a deformable lung phantom for the evaluation of deformable registration

被引:38
|
作者
Chang, Jina [1 ]
Suh, Tae-Suk [1 ]
Lee, Dong-Soo [2 ]
机构
[1] Catholic Univ, Coll Med, Dept Biomed Engn, Seoul 137701, South Korea
[2] Seoul Natl Univ Hosp, Dept Nucl Med, Seoul 137701, South Korea
来源
关键词
deformable lung phantom; deformable registration; evaluation; IMAGE REGISTRATION; RADIATION-THERAPY; TECHNICAL NOTE; CT; MOTION; RADIOTHERAPY;
D O I
10.1120/jacmp.v11i1.3081
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A deformable lung phantom was developed to simulate patient breathing motion and to evaluate a deformable image registration algorithm. The phantom consisted of an acryl cylinder filled with water and a latex balloon located in the inner space of the cylinder. A silicon membrane was attached to the inferior end of the phantom. The silicon membrane was designed to simulate a real lung diaphragm and to reduce motor workload. This specific design was able to reduce the use of metal, which may prevent infrared sensing of the real position management (RPM) gating system for four-dimensional (4D) CT image acquisition. Verification of intensity based three-dimensional (3D) demons deformable registration was based on the peak exhale and peak inhale breathing phases. The registration differences ranged from 0.60 mm to 1.11 mm and accuracy was determined according to inner target deformation. The phantom was able to simulate features and deformation of a real human lung and has the potential for wide application for 4D radiation treatment planning.
引用
收藏
页码:281 / 286
页数:6
相关论文
共 50 条
  • [41] Is There a Threshold Limit in the Accuracy of Deformable Image Registration (DIR)? A Validation Study Using Deformable Bladder Phantom with Implanted Markers
    Varadhan, R.
    Hui, S.
    Overbeck, C.
    MEDICAL PHYSICS, 2014, 41 (06) : 174 - 175
  • [42] A Multi-Phase Cross-Modality Deformable Bio-Tissue Phantom for Deformable Image Registration Validation
    Qin, A.
    Snyder, M.
    Liu, M.
    Ding, X.
    Zheng, W.
    Liu, Q.
    Chen, S.
    Liang, J.
    Yan, D.
    MEDICAL PHYSICS, 2020, 47 (06) : E406 - E406
  • [43] Evaluation of dose recalculation vs dose deformation in a commercial platform for deformable image registration with a computational phantom
    Fusella, Marco
    Giglioli, Francesca R.
    Fiandra, Christian
    Ragona, Riccardo
    MEDICAL DOSIMETRY, 2018, 43 (01) : 82 - 90
  • [44] B-spline deformable image registration algorithm evaluation using numerical and physical phantom.
    Badey, A.
    Tolsa, S.
    Bodez, V.
    Khamphan, C.
    Jaegle, E.
    Alayrach, M. E.
    Martinez, P.
    Garcia, R.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1133 - S1134
  • [45] Deformable image registration for geometrical evaluation of DIBH radiotherapy treatment of lung cancer patients
    Ottosson, W.
    Andersen, J. A. Lykkegaard
    Borrisova, S.
    Mellemgaard, A.
    Behrens, C. F.
    XVII INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY (ICCR 2013), 2014, 489
  • [46] Evaluation of Deformable Registration for Correcting Respiratory Motion in 4DCT Lung Images
    Larrue, A.
    van Elmpt, W.
    Kaster, F.
    Kadir, T.
    Gooding, M.
    MEDICAL PHYSICS, 2014, 41 (06) : 196 - 196
  • [47] Evaluation of deformable registration of patient lung 4DCT with subanatomical region segmentations
    Wu, Ziji
    Rietzel, Eike
    Boldea, Vlad
    Sarrut, David
    Sharp, Gregory C.
    MEDICAL PHYSICS, 2008, 35 (02) : 775 - 781
  • [48] Evaluation of the deformable image registration algorithm in Velocity image registration software
    Fullarton, R.
    Ghirmay, K.
    Dom, W.
    Crees, L.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S974 - S974
  • [49] Evaluation of a deformable registration algorithm for subsequent lung computed tomography imaging during radiochemotherapy
    Stuetzer, Kristin
    Haase, Robert
    Lohaus, Fabian
    Barczyk, Steffen
    Exner, Florian
    Loeck, Steffen
    Ruehaak, Jan
    Lassen-Schmidt, Bianca
    Corr, Doerte
    Richter, Christian
    MEDICAL PHYSICS, 2016, 43 (09) : 5028 - 5039
  • [50] Validation of Accuracy in Deformable Image Registration by Use of Three-Dimensional Phantom
    Kobayashi, M.
    Hayashi, N.
    Egami, K.
    Yasui, K.
    MEDICAL PHYSICS, 2018, 45 (06) : E228 - E228