Development of a deformable lung phantom for the evaluation of deformable registration

被引:38
|
作者
Chang, Jina [1 ]
Suh, Tae-Suk [1 ]
Lee, Dong-Soo [2 ]
机构
[1] Catholic Univ, Coll Med, Dept Biomed Engn, Seoul 137701, South Korea
[2] Seoul Natl Univ Hosp, Dept Nucl Med, Seoul 137701, South Korea
来源
关键词
deformable lung phantom; deformable registration; evaluation; IMAGE REGISTRATION; RADIATION-THERAPY; TECHNICAL NOTE; CT; MOTION; RADIOTHERAPY;
D O I
10.1120/jacmp.v11i1.3081
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A deformable lung phantom was developed to simulate patient breathing motion and to evaluate a deformable image registration algorithm. The phantom consisted of an acryl cylinder filled with water and a latex balloon located in the inner space of the cylinder. A silicon membrane was attached to the inferior end of the phantom. The silicon membrane was designed to simulate a real lung diaphragm and to reduce motor workload. This specific design was able to reduce the use of metal, which may prevent infrared sensing of the real position management (RPM) gating system for four-dimensional (4D) CT image acquisition. Verification of intensity based three-dimensional (3D) demons deformable registration was based on the peak exhale and peak inhale breathing phases. The registration differences ranged from 0.60 mm to 1.11 mm and accuracy was determined according to inner target deformation. The phantom was able to simulate features and deformation of a real human lung and has the potential for wide application for 4D radiation treatment planning.
引用
收藏
页码:281 / 286
页数:6
相关论文
共 50 条
  • [31] Development of a Hyrbid Biomechanical Model Based Deformable Image Registration; Application in Lung
    Samavati, N.
    Al-Mayah, A.
    Brock, K.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [32] Characterization of a new physical phantom for testing rigid and deformable image registration
    Wu, Richard Y.
    Liu, Amy Y.
    Wisdom, Paul
    Zhu, Xiaorong Ronald
    Frank, Steven J.
    Fuller, Clifton D.
    Gunn, Gary Brandon
    Palmer, Matthew B.
    Wages, Cody A.
    Gillin, Michael T.
    Yang, Jinzhong
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (01): : 145 - 153
  • [33] DEFORMABLE SURFACE REGISTRATION FOR BREAST TUMORS TRACKIN G: A PHANTOM STUDY
    Maris, Bogdan Mihai
    Fiorini, Paolo
    [J]. 2017 13TH IASTED INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING (BIOMED), 2017, : 20 - 25
  • [34] Validation of Deformable Image Registration Software Using a Standard CT Phantom
    Verdecchia, K.
    Qiu, L.
    Magnelli, A.
    Balik, S.
    Kost, S.
    Godley, A.
    Xia, P.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3174 - 3175
  • [35] Construction of an anthropopathic abdominal phantom for accuracy validation of deformable image registration
    Liao, Y. L.
    Chen, H. B.
    Zhou, L. H.
    Zhen, X.
    [J]. TECHNOLOGY AND HEALTH CARE, 2016, 24 : S717 - S723
  • [36] Deformable Lung CT Registration by Decomposing Large Deformation
    Zou, Jing
    Liu, Lihao
    Song, Youyi
    Choi, Kup-Sze
    Qin, Jing
    [J]. BIOMEDICAL IMAGE REGISTRATION (WBIR 2022), 2022, 13386 : 185 - 189
  • [37] Evaluation of deformable image registration between external beam radiotherapy and HDR brachytherapy for cervical cancer with a 3D-printed deformable pelvis phantom
    Kadoya, Noriyuki
    Miyasaka, Yuya
    Nakajima, Yujiro
    Kuroda, Yoshihiro
    Ito, Kengo
    Chiba, Mizuki
    Sato, Kiyokazu
    Dobashi, Suguru
    Yamamoto, Takaya
    Takahashi, Noriyoshi
    Kubozono, Masaki
    Takeda, Ken
    Jingu, Keiichi
    [J]. MEDICAL PHYSICS, 2017, 44 (04) : 1445 - 1455
  • [38] Dose warping performance in deformable image registration in lung
    Moriya, Shunsuke
    Tachibana, Hidenobu
    Kitamura, Nozomi
    Sawant, Amit
    Sato, Masanori
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 37 : 16 - 23
  • [39] Deformable image registration
    Shen, JK
    Matuszewski, BJ
    Shark, LK
    [J]. 2005 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), VOLS 1-5, 2005, : 3353 - 3356
  • [40] Feasibility of a Novel Evaluation Method for Deformable Image Registration-Based Dose Accumulation for HDR Brachytherapy with a 3D-Printed Deformable Phantom
    Abe, K.
    Kadoya, N.
    Hashimoto, S.
    Miyasaka, Y.
    Nakajima, Y.
    Ito, K.
    Sato, K.
    Takeda, K.
    Jingu, K.