Development of a deformable lung phantom for the evaluation of deformable registration

被引:38
|
作者
Chang, Jina [1 ]
Suh, Tae-Suk [1 ]
Lee, Dong-Soo [2 ]
机构
[1] Catholic Univ, Coll Med, Dept Biomed Engn, Seoul 137701, South Korea
[2] Seoul Natl Univ Hosp, Dept Nucl Med, Seoul 137701, South Korea
来源
关键词
deformable lung phantom; deformable registration; evaluation; IMAGE REGISTRATION; RADIATION-THERAPY; TECHNICAL NOTE; CT; MOTION; RADIOTHERAPY;
D O I
10.1120/jacmp.v11i1.3081
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A deformable lung phantom was developed to simulate patient breathing motion and to evaluate a deformable image registration algorithm. The phantom consisted of an acryl cylinder filled with water and a latex balloon located in the inner space of the cylinder. A silicon membrane was attached to the inferior end of the phantom. The silicon membrane was designed to simulate a real lung diaphragm and to reduce motor workload. This specific design was able to reduce the use of metal, which may prevent infrared sensing of the real position management (RPM) gating system for four-dimensional (4D) CT image acquisition. Verification of intensity based three-dimensional (3D) demons deformable registration was based on the peak exhale and peak inhale breathing phases. The registration differences ranged from 0.60 mm to 1.11 mm and accuracy was determined according to inner target deformation. The phantom was able to simulate features and deformation of a real human lung and has the potential for wide application for 4D radiation treatment planning.
引用
收藏
页码:281 / 286
页数:6
相关论文
共 50 条
  • [21] A Pitfall of a Deformable Image Registration in Lung Cancer
    Sugawara, Y.
    Tachibana, H.
    Moriya, S.
    Sawant, A.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 219 - 219
  • [23] Development of a deformable lung phantom with 3D-printed flexible airways
    Shin, Dong-Seok
    Kang, Seong-Hee
    Kim, Kyeong-Hyeon
    Kim, Tae-Ho
    Kim, Dong-Su
    Chung, Jin-Beom
    Lucero, Steven Andrew
    Suh, Tae Suk
    Yamamoto, Tokihiro
    [J]. MEDICAL PHYSICS, 2020, 47 (03) : 898 - 908
  • [24] An externally and internally deformable, programmable lung motion phantom
    Cheung, Yam
    Sawant, Amit
    [J]. MEDICAL PHYSICS, 2015, 42 (05) : 2585 - 2593
  • [25] An Easy to Create In-House Phantom for TG-132 Deformable Image Registration Evaluation
    Martin, T.
    Saenz, D.
    Myers, P.
    Rasmussen, K.
    Stathakis, S.
    Papanikolaou, N.
    Kirby, N.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E568 - E569
  • [26] Development of a physical geometric phantom for deformable image registration credentialing of radiotherapy centers for a clinical trial
    Kadoya, Noriyuki
    Sakulsingharoj, Siwaporn
    Kron, Tomas
    Yao, Adam
    Hardcastle, Nicholas
    Bergman, Alanah
    Okamoto, Hiroyuki
    Mukumoto, Nobutaka
    Nakajima, Yujiro
    Jingu, Keiichi
    Nakamura, Mitsuhiro
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (07): : 255 - 265
  • [27] Evaluation of the Dosimetric Characteristics of Salvage Lung SBRT with Image Deformable Registration Technique
    Li, Kaile
    Jung, Eward
    [J]. JOURNAL OF THORACIC ONCOLOGY, 2015, 10 (09) : S565 - S565
  • [28] Evaluation of Lung Dose Using Deformable 4DCT Registration Method
    Li, J.
    Chan, M.
    Hu, Y.
    Burman, C.
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 3324 - +
  • [29] Evaluation of the Velocity Deformable Image Registration Algorithm
    Polan, D.
    Kamp, J.
    Lee, J. Y.
    Chapman, C.
    Green, M.
    Payal, S.
    Kessler, M.
    Brock, K.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3426 - 3426
  • [30] Evaluation of Lung Hysteresis using a Bifurcation Tracking Code and Deformable Image Registration
    Moseley, J. L.
    Hunter, S. F.
    Al-Mayah, A.
    Brock, K. K.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S43 - S43