A novel deformable lung phantom with programably variable external and internal correlation

被引:7
|
作者
Ranjbar, Maida [1 ]
Sabouri, Pouya [1 ]
Repetto, Carlo [1 ]
Sawant, Amit [1 ]
机构
[1] Univ Maryland, Dept Radiat Oncol, Sch Med, Baltimore, MD 21201 USA
基金
美国国家卫生研究院;
关键词
deformable lung phantom; programmable; respiratory motion management; surrogate-based lung motion model; variable correlation; REAL-TIME TUMOR; RESPIRATORY MOTION; GATED RADIOTHERAPY; IMAGE REGISTRATION; QUALITY-ASSURANCE; LOCALIZATION; VERIFICATION; MOVEMENT; SYSTEM; CANCER;
D O I
10.1002/mp.13507
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Lung motion phantoms used to validate radiotherapy motion management strategies have fairly simplistic designs that do not adequately capture complex phenomena observed in human respiration such as external and internal deformation, variable hysteresis and variable correlation between different parts of the thoracic anatomy. These limitations make reliable evaluation of sophisticated motion management techniques quite challenging. In this work, we present the design and implementation of a programmable, externally and internally deformable lung motion phantom that allows for a reproducible change in external-internal and internal-internal correlation of embedded markers. Methods An in-house-designed lung module, made from natural latex foam was inserted inside the outer shell of a commercially available lung phantom (RSD, Long Beach, CA, USA). Radiopaque markers were placed on the external surface and embedded into the lung module. Two independently programmable high-precision linear motion actuators were used to generate primarily anterior-posterior (AP) and primarily superior-inferior (SI) motion in a reproducible fashion in order to enable (a) variable correlation between the displacement of interior volume and the exterior surface, (b) independent changes in the amplitude of the AP and SI motions, and (c) variable hysteresis. The ability of the phantom to produce complex and variable motion accurately and reproducibly was evaluated by programming the two actuators with mathematical and patient-recorded lung tumor motion traces, and recording the trajectories of various markers using kV fluoroscopy. As an example application, the phantom was used to evaluate the performance of lung motion models constructed from kV fluoroscopy and 4DCT images. Results The phantom exhibited a high degree of reproducibility and marker motion ranges were reproducible to within 0.5 mm. Variable correlation was observed between the displacements of internal-internal and internal-external markers. The SI and AP components of motion of a specific marker had a correlation parameter that varied from -11 to 17. Monitoring a region of interest on the phantom's surface to estimate internal marker motion led to considerably lower uncertainties than when a single point was monitored. Conclusions We successfully designed and implemented a programmable, externally and internally deformable lung motion phantom that allows for a reproducible change in external-internal and internal-internal correlation of embedded markers.
引用
收藏
页码:1995 / 2005
页数:11
相关论文
共 50 条
  • [31] Towards Quality Assurance of 4D Radiotherapy Using a Deformable Lung Phantom
    Serban, M.
    Alexander, A.
    Seuntjens, J.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [32] Correlation identification between internal/external motion signals
    Wu, Huanmei
    Zhao, Qingya
    Berbeco, Ross
    Nishioka, Seiko
    Shirato, Hiroki
    Jiang, Steve B.
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [33] Correlation between internal and external stages of rose development
    Chimonidou-Pavlidou, D
    XXV INTERNATIONAL HORTICULTURAL CONGRESS, PROCEEDINGS - PT 5: CULTURE TECHNIQUES WITH SPECIAL EMPHASIS ON ENVIRONMENTAL IMPLICATIONS CHEMICAL, PHYSICAL AND BIOLOGICAL MEANS OF REGULATING CROP GROWTH IN ORNAMENTALS AND OTHER CROPS, 2000, (515): : 233 - 244
  • [34] CORRELATION OF EXTERNAL AND INTERNAL INDICES OF VENTRICULAR FUNCTION IN MAN
    MARTIN, CE
    SHAVER, JA
    THOMPSON, ME
    LEONARD, JJ
    CIRCULATION, 1970, 42 (04) : I121 - &
  • [35] INTERNAL-EXTERNAL LOCUS OF CONTROL - PROMISING REHABILITATION VARIABLE
    MACDONALD, AP
    JOURNAL OF COUNSELING PSYCHOLOGY, 1971, 18 (02) : 111 - +
  • [37] IS INTERNAL-EXTERNAL-CONTROL AN AGE-RELATED VARIABLE
    LAO, RC
    JOURNAL OF PSYCHOLOGY, 1976, 92 (01): : 3 - 7
  • [39] Shear-deformable thin-walled composite Beams in internal and external resonance
    Machado, Sebastian P.
    Martin Saravia, C.
    COMPOSITE STRUCTURES, 2013, 97 : 30 - 39
  • [40] Evaluation of deformable image registration between external beam radiotherapy and HDR brachytherapy for cervical cancer with a 3D-printed deformable pelvis phantom
    Kadoya, Noriyuki
    Miyasaka, Yuya
    Nakajima, Yujiro
    Kuroda, Yoshihiro
    Ito, Kengo
    Chiba, Mizuki
    Sato, Kiyokazu
    Dobashi, Suguru
    Yamamoto, Takaya
    Takahashi, Noriyoshi
    Kubozono, Masaki
    Takeda, Ken
    Jingu, Keiichi
    MEDICAL PHYSICS, 2017, 44 (04) : 1445 - 1455