Effect of the anti-scatter grid and target/filters in full-field digital mammography

被引:4
|
作者
Chakraborty, DP [1 ]
机构
[1] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
关键词
FFDM; measurements; CAMPI; digital mammography; grid; target-filter;
D O I
10.1117/12.349570
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Computer Analysis Of Mammography Phantom Images (CAMPI) is a method for making quantitative measurements of image quality. This paper reports on further applications of the method to a prototype: full-field digital mammography (FFDM) machine. The specific aim was to investigate the effect on speck Signal-to-Noise-Ratio (SNR) of grid vs. non-grid techniques and different target-filter imaging conditions, for 4-cm thick phantoms. Images of a 50-50 composition, 4-cm thick phantom containing a mammography accreditation phantom insert plate, were acquired on a General Electric FFDM machine under conditions of constant pixel value and constant mean glandular dose. They were obtained under conditions of grid and no-grid with the Mo-Mo target/filter. Also acquired were 4-cm phantom grid images at constant dose using different targets-filter combinations (Mo/Mo, Mo/Rh, Rh/Rh) and different phantom material glandular-fat compositions (percentages: 30-70, 50-50, 70-30). Analyses of the images yielded signal-to-noise-ratio (SNR) for the specks and a non-uniformity measure. The SNR was converted to a Figure of Merit (FOM) by dividing by the square root of the mean glandular dose. For the grid-non-grid study, the FOM plots showed a broad maximum at about 26-28 kVp, meaning that this range is optimal in dose efficiency for imaging a 4-cm breast of 50-50 composition. The non-grid FOM values were greater than the grid values, meaning that the former was more dose-efficient. For the Target/Filter study the FOM also showed broad maxima as a function of kVp. The overall trends were as follows: (1) the Mo-Rh combination was superior to the Mo-Mo combination for all tissue compositions and kVps, and was generally superior to Rh-Rh except for kVp >30. (2) The optimal kVp moves towards higher values for more glandular (dense) breast equivalent material; (3) At the optimal kVp, Mo-Rh is the superior combination, outperforming both Mo-Mo and Rh-Rh for imaging a 4-cm breast. The non-uniformity was higher by 60% for the non-grid condition, and this negated its dose efficiency advantage: In the non-grid mode the non-uniformity is quite dependent on the phantom dimensions and position, implying that scatter is a si,significant contributing factor. The Rh-Rh combination also yielded a higher non-uniformity than did Mo-Mo and Mo-Rh. The Mo-Rh target filter combination appears to be the best overall choice for imaging the 4-cm breast of arbitrary composition. In-spite of its superior dose efficiency, we recommend-against using the non-grid technique until a better uniformity correction procedure is adopted.
引用
收藏
页码:878 / 885
页数:8
相关论文
共 50 条
  • [21] Current status of full-field digital mammography
    Pisano, ED
    RADIOLOGY, 2000, 214 (01) : 26 - 28
  • [22] Mammographic Artifacts on Full-Field Digital Mammography
    Jae Jeong Choi
    Sung Hun Kim
    Bong Joo Kang
    Byung Gil Choi
    ByungJoo Song
    Haijo Jung
    Journal of Digital Imaging, 2014, 27 : 231 - 236
  • [23] Advantages of gridless full-field digital mammography
    Nykänen, K
    Siltanen, S
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 137 - 146
  • [24] Current status of full-field digital mammography
    Pisano, ED
    Yaffe, MJ
    Hemminger, BM
    Hendrick, RE
    Niklason, LT
    Maidment, ADA
    Kimme-Smith, CM
    Feig, SA
    Sickles, EA
    Braeuning, MP
    ACADEMIC RADIOLOGY, 2000, 7 (04) : 266 - 280
  • [25] Design of linear anti-scatter grid geometry with optimum performance for screen-film and digital mammography systems
    Khodajou-Chokami, H.
    Sohrabpour, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (15): : 5753 - 5765
  • [26] Experimental Evaluation of a New Anti-Scatter Grid for Digital Radiographic Systems
    Fetterly, K.
    Schueler, B.
    MEDICAL PHYSICS, 2008, 35 (06) : 2677 - +
  • [27] Dual harmonic anti-scatter grid artefact removal for digital radiography
    Ostojic, Vladimir S.
    Starcevic, Dorde S.
    Petrovic, Vladimir S.
    2017 25TH TELECOMMUNICATION FORUM (TELFOR), 2017, : 326 - 329
  • [28] Performance of full-field digital mammography versus digital breast
    Wang, Mengru
    Zhuang, Shan
    Sheng, Liuli
    Zhao, Yu Nian
    Shen, Wenrong
    PRECISION MEDICAL SCIENCES, 2022, 11 (02): : 56 - 61
  • [29] Radiation Exposure of Digital Breast Tomosynthesis Using an Antiscatter Grid Compared With Full-Field Digital Mammography
    Paulis, Leonie E.
    Lobbes, Marc B. I.
    Lalji, Ulrich C.
    Gelissen, Nicky
    Bouwman, Ramona W.
    Wildberger, Joachim E.
    Jeukens, Cecile R. L. P. N.
    INVESTIGATIVE RADIOLOGY, 2015, 50 (10) : 679 - 685
  • [30] Clinical evaluation of CR mammography in comparison with full-field digital mammography
    Uchiyama, N
    Kobayashi, H
    Tanikoshi, M
    Machida, M
    Tajima, H
    Kumazaki, T
    Moriyama, N
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 494 - 496