Accuracy of the i-STAT™ bedside blood gas analyser

被引:54
|
作者
Sediame, S
Zerah-Lancner, F
d'Ortho, MP
Adnot, S
Harf, A [1 ]
机构
[1] Hop Henri Mondor, Serv Physiol Explorat Fonctionnelles, F-94010 Creteil, France
[2] Hop Henri Mondor, INSERM, U492, F-94010 Creteil, France
关键词
acidosis; high oxygen tension; permissive hypercapnia; point-of-care testing; thin-film electrode biosensors;
D O I
10.1034/j.1399-3003.1999.14a36.x
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
The performance of the i-STAT portable clinical analyser for measuring blood gases and pH was evaluated,vith reference to a conventional blood gas analyser (ABL520 Radiometer). Ninety-two samples from the routine blood gas analysis laboratory were chosen according to a wide distribution of partial pressure of carbon dioxide (Pa,CO2), partial pressure oxygen (Pa,O-2) and pH and then analysed. All measurements were performed in duplicate by trained technicians from the central hospital laboratory. Differences between duplicate measurements were computed for Pa,CO2: (1.2 versus 0.4%), Pa,O-2 (1.7 versus 1.1%) and pH (0.06 versus 0.02%), for the i-STAT and ABL520, respectively. pH and Pa,CO2 values measured with the i-STAT were very close to those obtained with the ABL520, the difference (mean+/-sD) being 0.006+/-0.018 and -0.13+/-0.17 kPa, respectively. Statistical analysis showed that the differences between analysers did not depend on values of pH or Pa,CO2 The performance of the analysers depended on the level of PO2. Below 15 kPa (n=48), the two systems gave nearly identical values, the mean difference was 0.01+/-0.37 kPa. Between 16 and 55 kPa (n=44), there was a systematic but small (-0.69+0.67 kPa) underestimation of Pa,O-2 measured with the i-STAT (p<10(-8)). In conclusion, this study shows that blood gas analysis using the i-STAT portable device is comparable,vith that performed by a conventional laboratory blood gas analyser.
引用
收藏
页码:214 / 217
页数:4
相关论文
共 50 条
  • [21] Analytical evaluation of i-STAT portable clinical analyzer for blood gas and electrolyte analyses in pediatric samples.
    Murthy, JN
    Hicks, JM
    Soldin, SJ
    CLINICAL CHEMISTRY, 1996, 42 (06) : 198 - 198
  • [22] Infringement suit brought by Nova against i-STAT dismissed - i-STAT plans rule 11 action
    不详
    BIOTECHNOLOGY LAW REPORT, 1998, 17 (02): : 298 - 298
  • [23] Selected Blood Chemistry and Gas Reference Ranges for Broiler Breeders Using the i-STAT® Handheld Clinical Analyzer
    Martin, Michael P.
    Wineland, Michael
    Barnes, H. John
    AVIAN DISEASES, 2010, 54 (03) : 1016 - 1020
  • [24] Evaluation of indirect blood pressure measurement techniques (Doppler) and the comparing point of care blood gas analyzer (I-STAT) values
    Acierno, Mark
    Smith, Julie
    Tully, Thomas N., Jr.
    Migallon-Guzman, David
    Mitchell, Mark A.
    PROCEEDINGS OF THE ASSOCIATION OF AVIAN VETERINARIANS 28TH ANNUAL CONFERENCE AND EXPO, 2007, : 15 - +
  • [25] I-STAT: The Instant Portable Analyzer
    Wynn, Alice
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2012, 138 : A058 - A058
  • [26] Analysis of bloodgas, electrolytes and glucose from intraosseous samples using an i-STAT® point-of-care analyser
    Veldhoen, Esther S.
    de Vooght, Karen M. K.
    Slieker, Martijn G.
    Versluys, Anne B.
    Turner, Nigel Mcb.
    RESUSCITATION, 2014, 85 (03) : 359 - 363
  • [27] Evaluation of the i-STAT® Portable Clinical Analyzer for the determination of blood creatinine.
    Marver, CL
    Santrach, PJ
    Burritt, MF
    CLINICAL CHEMISTRY, 1999, 45 (06) : A33 - A33
  • [28] Falsely increased i-STAT chloride results for blood samples with increased urea
    Pinckard, JK
    Zahn, J
    Ashby, L
    Parvin, CA
    Scott, MG
    CLINICAL CHEMISTRY, 2001, 47 (11) : 2064 - 2066
  • [29] Evaluation of the i-STAT analyzer for determination of ionized calcium concentrations in bovine blood
    Yilmaz, Oznur
    Karapinar, Tolga
    VETERINARY CLINICAL PATHOLOGY, 2019, 48 (01) : 31 - 35
  • [30] Accuracy and reliability of the i-STAT point-of-care device for the determination of haemoglobin concentration before and after major blood loss
    Ng, W. L.
    Short, T. G.
    Gunn, K. N.
    Fuge, G. S.
    Slon, B.
    ANAESTHESIA AND INTENSIVE CARE, 2014, 42 (04) : 495 - 499