Accuracy of the i-STAT™ bedside blood gas analyser

被引:54
|
作者
Sediame, S
Zerah-Lancner, F
d'Ortho, MP
Adnot, S
Harf, A [1 ]
机构
[1] Hop Henri Mondor, Serv Physiol Explorat Fonctionnelles, F-94010 Creteil, France
[2] Hop Henri Mondor, INSERM, U492, F-94010 Creteil, France
关键词
acidosis; high oxygen tension; permissive hypercapnia; point-of-care testing; thin-film electrode biosensors;
D O I
10.1034/j.1399-3003.1999.14a36.x
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
The performance of the i-STAT portable clinical analyser for measuring blood gases and pH was evaluated,vith reference to a conventional blood gas analyser (ABL520 Radiometer). Ninety-two samples from the routine blood gas analysis laboratory were chosen according to a wide distribution of partial pressure of carbon dioxide (Pa,CO2), partial pressure oxygen (Pa,O-2) and pH and then analysed. All measurements were performed in duplicate by trained technicians from the central hospital laboratory. Differences between duplicate measurements were computed for Pa,CO2: (1.2 versus 0.4%), Pa,O-2 (1.7 versus 1.1%) and pH (0.06 versus 0.02%), for the i-STAT and ABL520, respectively. pH and Pa,CO2 values measured with the i-STAT were very close to those obtained with the ABL520, the difference (mean+/-sD) being 0.006+/-0.018 and -0.13+/-0.17 kPa, respectively. Statistical analysis showed that the differences between analysers did not depend on values of pH or Pa,CO2 The performance of the analysers depended on the level of PO2. Below 15 kPa (n=48), the two systems gave nearly identical values, the mean difference was 0.01+/-0.37 kPa. Between 16 and 55 kPa (n=44), there was a systematic but small (-0.69+0.67 kPa) underestimation of Pa,O-2 measured with the i-STAT (p<10(-8)). In conclusion, this study shows that blood gas analysis using the i-STAT portable device is comparable,vith that performed by a conventional laboratory blood gas analyser.
引用
收藏
页码:214 / 217
页数:4
相关论文
共 50 条
  • [31] Accuracy of the pH, PO2, and PCO2 Tests in the i-STAT® G3+ Cartridge Using the i-STAT 1 System for Venous, Arterial and Capillary Whole Blood Specimens in Clinical Settings
    Kornfeld, S. F.
    Aguirre, M. Gonzalez
    Mohammed, A.
    Kovacevic, S.
    Zhang, H.
    Gupta, M.
    CLINICAL CHEMISTRY, 2024, 70 : I124 - I124
  • [32] Abbott公司收购i-STAT公司
    胡子
    中国医疗器械杂志, 2004, (02) : 127 - 127
  • [33] QUALITY-CONTROL FOR THE I-STAT ANALYZER
    UTZ, C
    GIBSON, C
    HORTIN, GL
    CLINICAL CHEMISTRY, 1995, 41 (06) : S157 - S157
  • [34] I-STAT - INTERACTIVE STATISTICAL PROGRAM PACKAGE
    ROSENBLO.L
    CHAPMAN, K
    BEHAVIOR RESEARCH METHODS & INSTRUMENTATION, 1974, 6 (01): : 56 - 56
  • [35] i-STAT biosensor system to be distributed in Europe
    不详
    BIOSENSORS & BIOELECTRONICS, 1996, 11 (09): : R2 - R2
  • [36] Analytical performance of the i-STAT cardiac troponin I assay
    Apple, FS
    Murakami, MM
    Christenson, RH
    Campbell, JL
    Miller, CJ
    Hock, KG
    Scott, MG
    CLINICA CHIMICA ACTA, 2004, 345 (1-2) : 123 - 127
  • [37] Comparison of blood gas results obtained on Abbott i-Stat® and on Radiometer ABL 800 Flex® analyzers Impact for the clinical decision
    Jouffroy, Romain
    Laney, Maude
    Leguillier, Teddy
    Nivet-Antoine, Valerie
    Beaudeux, Jean-Louis
    ANNALES DE BIOLOGIE CLINIQUE, 2022, 80 (06) : 521 - 525
  • [38] Evaluation of i-STAT® Point of Care Blood Gas Cartridges and Competitor Blood Gas Devices Against Reference Standard for PCO2 and PO2
    Beattie, C.
    Thibodeau, L.
    CLINICAL CHEMISTRY, 2024, 70
  • [39] Haematology, blood chemistry and urine parameters of free-ranging plains viscachas (Lagostomus maximus) in Argentina determined by use of a portable blood analyser (i-STAT®) and conventional laboratory methods
    Wenker, C. J.
    Hunziker, D.
    Lopez, J.
    Oppliger, H.
    Forrer, R.
    Lutz, H.
    JOURNAL OF VETERINARY MEDICINE SERIES A-PHYSIOLOGY PATHOLOGY CLINICAL MEDICINE, 2007, 54 (05): : 260 - 264
  • [40] Point of care blood gas testing compared with traditional methods; a comparison between IL and i-STAT blood gas analysis utilizing more than 2000 samples
    Fiallos, M
    Forth, LA
    Orlowski, J
    Hanhan, U
    Suggs, S
    CRITICAL CARE MEDICINE, 1999, 27 (01) : A117 - A117