摘要
Background. Movement of the stent delivery system in the coronary bed as a result of the cardiac cycle is a well-known clinical observation that usually is either underestimated or ignored. This effect may potentially jeopardize precise stent deployment. We used a novel technology to objectively measure the relative intracoronary device motion in the different coronary segments throughout the cardiac cycle. Methods. A total of 193 patients undergoing coronary angiography were enrolled and their studies were analyzed for device movement using the SyncVision System (Philips Volcano). The SyncVision System is an add-on image-processing system with unique enhancement and stabilization capabilities. A new feature, the device-motion indication, can precisely display the predeployment device movement measurement (DMM). The device movements within the three segments of each coronary artery were recorded. Results. We identified 218 branch point sites. Median axial displacement was 2.97 mm at the right coronary artery (RCA), 2.22 mm at the left circumflex, and 1.84 mm at the left anterior descending segments. The most movable segments were mid and distal RCA (P<. 05). Both heart rate and cardiac contractility significantly affected DMM. Conclusions. The study demonstrates an innovative feature of the SyncVision System as a tool to precisely measure relative device displacement. We claim that the relative device movement is an important quality metric to consider for achieving an effective stent implantation process.
引用
收藏
页码:421 / 424
页数:4
相关论文
共 50 条
  • [41] A novel multipurpose device for guided knee motion and loading during dynamic magnetic resonance imaging (vol 32, pg 500, 2022)
    Brisson, Nicholas M.
    Kraemer, Martin
    Krahl, Leonie A. N.
    Schill, Alexander
    Duda, Georg N.
    Reichenbach, Jurgen R.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2025, 35 (01): : 116 - 116
  • [42] Effect of distal protection device on regional wall motion recovery in patients with acute anterior myocardial infarction after percutaneous coronary intervention: a strain echocardiographic study
    Ohara, Y.
    Kawada, S.
    Habara, M.
    Hamada, T.
    Taguchi, E.
    Ohgo, T.
    Yamamoto, M.
    Sugimoto, K.
    Yamamoto, K.
    Furuno, T.
    EUROPEAN HEART JOURNAL, 2007, 28 : 715 - 715
  • [43] Design and study of ultrasound-based automatic patient movement monitoring device for quantifying the intrafraction motion during teletherapy treatment
    Senthilkumar, S.
    Vinothraj, R.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (06): : 82 - 90
  • [44] Preclinical and clinical experience with the proxis device: A novel proximal occlusion system for prevention of distal embolization during percutaneous coronary intervention.
    Sievert, H
    Schuler, G
    Diederich, K
    Suetsch, G
    AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (6A): : 27H - 27H
  • [45] Predicting Temperature Fluctuation of Five Axis Controlled Compact Machine Tool Equipped with a Wave Motion Gear Device Based on a Thermal Network Model
    Ozawa, K.
    Hirogaki, T.
    Aoyama, E.
    2021 21ST INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS 2021), 2021, : 289 - 294
  • [46] Hand Motion Analysis Using the Imperial College Surgical Assessment Device Validation of a Novel and Objective Performance Measure in Ultrasound-Guided Peripheral Nerve Blockade
    Chin, Ki Jinn
    Tse, Cyrus
    Chan, Vincent
    Tan, Jyh Shen
    Lupu, Catalin Mario
    Hayter, Megan
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2011, 36 (03) : 213 - 219
  • [47] Concurrent and Angle-Trajectory Validity and Intra-Trial Reliability of a Novel Multi-View Image-Based Motion Analysis System
    Lee, Namgi
    Ahn, Junghoon
    Lim, Wootaek
    JOURNAL OF HUMAN KINETICS, 2023, 86 (01) : 31 - 40
  • [48] Simulation of infrared radiation images based on wearable device fiber optic temperature sensing in motion training state: Thermal energy image detection
    Lu, Peng
    Chen, Duanfeng
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2025, 59
  • [49] Image-based view-angle independent cardiorespiratory motion gating and coronary sinus catheter tracking for x-ray-guided cardiac electrophysiology procedures
    Panayiotou, Maria
    Rhode, Kawal S.
    King, Andrew P.
    Ma, Yingliang
    Cooklin, Michael
    O'Neill, Mark
    Gill, Jaswinder
    Rinaldi, C. A.
    Housden, R. James
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (20): : 8087 - 8108
  • [50] 3-D Respiratory Motion Compensation during EP Procedures by Image-Based 3-D Lasso Catheter Model Generation and Tracking
    Brost, Alexander
    Liao, Rui
    Hornegger, Joachim
    Strobel, Norbert
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2009, PT I, PROCEEDINGS, 2009, 5761 : 394 - +