Device Motion Indication: A Novel Image-Based Tool to Measure Relative Device Motion During Coronary Intervention

被引:0
|
作者
Abu Fanne, Rami [1 ]
Meisel, Simcha Ron [1 ]
Shotan, Avraham [1 ]
Frimerman, Aharon [1 ]
机构
[1] Technion Israel Inst Technol, Rappaport Fac Med, Hillel Yaffe Med Ctr, Haifa, Israel
来源
JOURNAL OF INVASIVE CARDIOLOGY | 2017年 / 29卷 / 12期
关键词
geographical miss; stent deployment; thrombosis; restenosis; ANGIOGRAPHY; ARTERIES; VELOCITY; CT;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Movement of the stent delivery system in the coronary bed as a result of the cardiac cycle is a well-known clinical observation that usually is either underestimated or ignored. This effect may potentially jeopardize precise stent deployment. We used a novel technology to objectively measure the relative intracoronary device motion in the different coronary segments throughout the cardiac cycle. Methods. A total of 193 patients undergoing coronary angiography were enrolled and their studies were analyzed for device movement using the SyncVision System (Philips Volcano). The SyncVision System is an add-on image-processing system with unique enhancement and stabilization capabilities. A new feature, the device-motion indication, can precisely display the predeployment device movement measurement (DMM). The device movements within the three segments of each coronary artery were recorded. Results. We identified 218 branch point sites. Median axial displacement was 2.97 mm at the right coronary artery (RCA), 2.22 mm at the left circumflex, and 1.84 mm at the left anterior descending segments. The most movable segments were mid and distal RCA (P<. 05). Both heart rate and cardiac contractility significantly affected DMM. Conclusions. The study demonstrates an innovative feature of the SyncVision System as a tool to precisely measure relative device displacement. We claim that the relative device movement is an important quality metric to consider for achieving an effective stent implantation process.
引用
收藏
页码:421 / 424
页数:4
相关论文
共 50 条
  • [11] Coronary MR Angiography in patients with coronary artery disease using image-based respiratory motion compensation
    Markus Henningsson
    Konstantinos Bratis
    Eike Nagel
    Rene Botnar
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [12] Novel Walking Assist Device Based on Generic Human Motion Tracking Criteria
    El Dine, Kamal Mohy
    Yang, Chuan
    Nozaki, Takahiro
    Murakami, Toshiyuki
    2016 IEEE 14TH INTERNATIONAL WORKSHOP ON ADVANCED MOTION CONTROL (AMC), 2016, : 38 - 43
  • [13] MR Image-Based Geometric and Hemodynamic Investigation of the Right Coronary Artery with Dynamic Vessel Motion
    Torii, Ryo
    Keegan, Jennifer
    Wood, Nigel B.
    Dowsey, Andrew W.
    Hughes, Alun D.
    Yang, Guang-Zhong
    Firmin, David N.
    Thom, Simon A. McG
    Xu, X. Yun
    ANNALS OF BIOMEDICAL ENGINEERING, 2010, 38 (08) : 2606 - 2620
  • [14] Image-based coronary tracking and beat-to-beat motion compensation: Feasibility for improving coronary MR angiography
    Dewan, Maneesh
    Hager, Gregory D.
    Lorenz, Christine H.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (03) : 604 - 615
  • [15] MR Image-Based Geometric and Hemodynamic Investigation of the Right Coronary Artery with Dynamic Vessel Motion
    Ryo Torii
    Jennifer Keegan
    Nigel B. Wood
    Andrew W. Dowsey
    Alun D. Hughes
    Guang-Zhong Yang
    David N. Firmin
    Simon A. McG. Thom
    X. Yun Xu
    Annals of Biomedical Engineering, 2010, 38 : 2606 - 2620
  • [16] A research protocol on leap motion tracking device: A novel intervention method in distal radial fracture rehabilitation
    Arora, Sakshi P.
    Naqvi, Waqar M.
    PLOS ONE, 2022, 17 (05):
  • [17] A novel multipurpose device for guided knee motion and loading during dynamic magnetic resonance imaging
    Brisson, Nicholas M.
    Kraemer, Martin
    Krahl, Leonie A. N.
    Schill, Alexander
    Duda, Georg N.
    Reichenbachc, Juergen R.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2022, 32 (04): : 500 - 513
  • [18] Reduction of vibration for main functional part in precision device based on sensitivity analysis with respect to relative motion
    Okubo, N
    Murase, Y
    Toi, T
    IMAC - PROCEEDINGS OF THE 16TH INTERNATIONAL MODAL ANALYSIS CONFERENCE, VOLS 1 AND 2, 1998, 3243 : 1081 - 1088
  • [20] A novel device for dynamic loading and stability measurement of inland vessels based on its rolling motion
    Sakib, Shadman