Device Motion Indication: A Novel Image-Based Tool to Measure Relative Device Motion During Coronary Intervention

被引:0
|
作者
Abu Fanne, Rami [1 ]
Meisel, Simcha Ron [1 ]
Shotan, Avraham [1 ]
Frimerman, Aharon [1 ]
机构
[1] Technion Israel Inst Technol, Rappaport Fac Med, Hillel Yaffe Med Ctr, Haifa, Israel
来源
JOURNAL OF INVASIVE CARDIOLOGY | 2017年 / 29卷 / 12期
关键词
geographical miss; stent deployment; thrombosis; restenosis; ANGIOGRAPHY; ARTERIES; VELOCITY; CT;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Movement of the stent delivery system in the coronary bed as a result of the cardiac cycle is a well-known clinical observation that usually is either underestimated or ignored. This effect may potentially jeopardize precise stent deployment. We used a novel technology to objectively measure the relative intracoronary device motion in the different coronary segments throughout the cardiac cycle. Methods. A total of 193 patients undergoing coronary angiography were enrolled and their studies were analyzed for device movement using the SyncVision System (Philips Volcano). The SyncVision System is an add-on image-processing system with unique enhancement and stabilization capabilities. A new feature, the device-motion indication, can precisely display the predeployment device movement measurement (DMM). The device movements within the three segments of each coronary artery were recorded. Results. We identified 218 branch point sites. Median axial displacement was 2.97 mm at the right coronary artery (RCA), 2.22 mm at the left circumflex, and 1.84 mm at the left anterior descending segments. The most movable segments were mid and distal RCA (P<. 05). Both heart rate and cardiac contractility significantly affected DMM. Conclusions. The study demonstrates an innovative feature of the SyncVision System as a tool to precisely measure relative device displacement. We claim that the relative device movement is an important quality metric to consider for achieving an effective stent implantation process.
引用
收藏
页码:421 / 424
页数:4
相关论文
共 50 条
  • [31] A novel 1-gram insect based device measuring visual motion along 5 optical directions
    Roubieu, Frederic L.
    Expert, Fabien
    Boyron, Marc
    Fuschlock, Benoit-Jeremy
    Viollet, Stephane
    Ruffier, Franck
    2011 IEEE SENSORS, 2011, : 687 - 690
  • [32] Stereo Vision and IMU based Real-Time Ego-Motion and Depth Image Computation on a Handheld Device
    Schmid, Korbinian
    Hirschmueller, Heiko
    2013 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2013, : 4671 - 4678
  • [33] Design for hip Abduction Assistive Device Based on Relationship between hip Joint Motion and Torque During Running
    Lee, Myunghyun
    Hong, Man Bok
    Kim, Gwang Tae
    Kim, Seonwoo
    2023 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, IROS, 2023, : 143 - 148
  • [34] A dual-centre study on the radioprotective effect of a novel X-ray protection device during coronary intervention
    Ma, J.
    Liu, K.
    Chen, W.
    Wang, T.
    Xu, Z.
    Li, Y.
    Zhao, B.
    Zhou, L.
    Wang, F.
    Li, C.
    CLINICAL RADIOLOGY, 2023, 78 (10) : E758 - E763
  • [35] Novel Insight into the "Geographical Miss Phenomenon": Device Motion Indicator, a New Feature to Evaluate Relative Axial Stent Movement inside Coronary Artery and to Optimise its Precise Deployment Site
    Abu Fanne, Rami M.
    Frimerman, Aharon
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B184 - B185
  • [36] Mechanical Design of Hospital Central Oxygen Supply Device for Novel Coronavirus Pneumonia Based on Optimal Nonholonomic Motion Planning
    Xu, Yunfei
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2020, 127 : 268 - 268
  • [37] CARDIOKYMOGRAPHY DURING EXERCISE TESTING - A NEW DEVICE FOR THE DETECTION OF CORONARY-ARTERY DISEASE AND LEFT-VENTRICULAR WALL MOTION ABNORMALITIES
    WEINER, DA
    MCCABE, CH
    DAGOSTINO, G
    CUTLER, SS
    RYAN, TJ
    AMERICAN JOURNAL OF CARDIOLOGY, 1983, 51 (08): : 1307 - 1311
  • [38] Proposition and Evaluation of a Novel Method Based on Videogrammetry to Measure Three-Dimensional Rib Motion During Breathing
    Sarro, Karine Jacon
    Silvatti, Amanda Piaia
    Aliverti, Andrea
    Barros, Ricardo M. L.
    JOURNAL OF APPLIED BIOMECHANICS, 2009, 25 (03) : 247 - 252
  • [39] The Null technique as a novel, potential first-line method of device delivery for complicated lesions during percutaneous coronary intervention
    Akima, Takashi
    Sakurai, Yasuo
    Nakajima, Kazuaki
    Koyama, Takashi
    IJC HEART & VASCULATURE, 2023, 47
  • [40] Whole-Heart Coronary MRA with 3D Affine Motion Correction Using 3D Image-Based Navigation
    Henningsson, Markus -
    Prieto, Claudia
    Chiribiri, Amedeo
    Vaillant, Ghislain
    Razavi, Reza
    Botnar, Rene M.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (01) : 173 - 181