Device Motion Indication: A Novel Image-Based Tool to Measure Relative Device Motion During Coronary Intervention

被引:0
|
作者
Abu Fanne, Rami [1 ]
Meisel, Simcha Ron [1 ]
Shotan, Avraham [1 ]
Frimerman, Aharon [1 ]
机构
[1] Technion Israel Inst Technol, Rappaport Fac Med, Hillel Yaffe Med Ctr, Haifa, Israel
来源
JOURNAL OF INVASIVE CARDIOLOGY | 2017年 / 29卷 / 12期
关键词
geographical miss; stent deployment; thrombosis; restenosis; ANGIOGRAPHY; ARTERIES; VELOCITY; CT;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Movement of the stent delivery system in the coronary bed as a result of the cardiac cycle is a well-known clinical observation that usually is either underestimated or ignored. This effect may potentially jeopardize precise stent deployment. We used a novel technology to objectively measure the relative intracoronary device motion in the different coronary segments throughout the cardiac cycle. Methods. A total of 193 patients undergoing coronary angiography were enrolled and their studies were analyzed for device movement using the SyncVision System (Philips Volcano). The SyncVision System is an add-on image-processing system with unique enhancement and stabilization capabilities. A new feature, the device-motion indication, can precisely display the predeployment device movement measurement (DMM). The device movements within the three segments of each coronary artery were recorded. Results. We identified 218 branch point sites. Median axial displacement was 2.97 mm at the right coronary artery (RCA), 2.22 mm at the left circumflex, and 1.84 mm at the left anterior descending segments. The most movable segments were mid and distal RCA (P<. 05). Both heart rate and cardiac contractility significantly affected DMM. Conclusions. The study demonstrates an innovative feature of the SyncVision System as a tool to precisely measure relative device displacement. We claim that the relative device movement is an important quality metric to consider for achieving an effective stent implantation process.
引用
收藏
页码:421 / 424
页数:4
相关论文
共 50 条
  • [21] Image-based haptic display via a novel pen-shaped haptic device on touch screens
    Lei Tian
    Aiguo Song
    Dapeng Chen
    Multimedia Tools and Applications, 2017, 76 : 14969 - 14992
  • [22] Image-based haptic display via a novel pen-shaped haptic device on touch screens
    Tian, Lei
    Song, Aiguo
    Chen, Dapeng
    MULTIMEDIA TOOLS AND APPLICATIONS, 2017, 76 (13) : 14969 - 14992
  • [23] Coronary MR angiography using image-based respiratory motion compensation with inline correction and fixed gating efficiency
    Henningsson, Markus
    Smink, Jouke
    van Ensbergen, Gerald
    Botnar, Rene
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (01) : 416 - 422
  • [24] A PARALLEL MAPPING OF OPTICAL FLOW TO COMPUTE UNIFIED DEVICE ARCHITECTURE FOR MOTION-BASED IMAGE SEGMENTATION
    Kuchnio, Peter
    Capson, David W.
    2009 16TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOLS 1-6, 2009, : 2325 - 2328
  • [25] DYNAMIC AND GUIDED KNEE MOTION UNDER LOADING DURING FAST MAGNETIC RESONANCE IMAGING: A NOVEL DEVICE
    Brisson, N. M.
    Kraemer, M.
    Reichenbach, J. R.
    Duda, G. N.
    OSTEOARTHRITIS AND CARTILAGE, 2021, 29 : S350 - S351
  • [26] Comparison of Image-Based and Reconstruction-Based Respiratory Motion Correction for Golden Radial Phase Encoding Coronary MR Angiography
    Paschke, Nadia K.
    Doessel, Olaf
    Schaeffter, Tobias
    Prieto, Claudia
    Kolbitsch, Christoph
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (04) : 964 - 971
  • [27] A novel automatic device to measure deformation inside transparent soil based on digital image correlation technology
    Sang, Yong
    Zhao, Jianlong
    Duan, Fuhai
    Sun, Weiqi
    Zhao, Honghua
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2019, 30 (03)
  • [28] A New Framework for Interleaved Scanning in Cardiovascular MR: Application to Image-Based Respiratory Motion Correction in Coronary MR Angiography
    Henningsson, Markus
    Mens, Giel
    Koken, Peter
    Smink, Jouke
    Botnar, Rene M.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (02) : 692 - 696
  • [29] Novel Similarity Metric for Image-Based Out-Of-Plane Motion Estimation in 3D Ultrasound
    Balakrishnan, Sathish
    Patel, Rajan
    Illanes, Alfredo
    Friebe, Michael
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 5739 - 5742
  • [30] Real-Time Respiratory Motion Correction for Cardiac Electrophysiology Procedures Using Image-Based Coronary Sinus Catheter Tracking
    Ma, YingLiang
    King, Andy P.
    Gogin, Nicolas
    Rinaldi, C. Aldo
    Gill, Jaswinder
    Razavi, Reza
    Rhode, Kawal S.
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2010, PT I, 2010, 6361 : 391 - +