Hand Motion Analysis Using the Imperial College Surgical Assessment Device Validation of a Novel and Objective Performance Measure in Ultrasound-Guided Peripheral Nerve Blockade

被引:67
|
作者
Chin, Ki Jinn [1 ]
Tse, Cyrus [1 ]
Chan, Vincent [1 ]
Tan, Jyh Shen [1 ]
Lupu, Catalin Mario [1 ]
Hayter, Megan [1 ]
机构
[1] Univ Toronto, Toronto Western Hosp, Dept Anesthesia, Toronto, ON M5T 2S8, Canada
关键词
REGIONAL ANESTHESIA; DEXTERITY; TOOL;
D O I
10.1097/AAP.0b013e31820d4305
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and Objectives: The Imperial College Surgical Assessment Device (ICSAD) has been validated in various settings as an objective tool to measure technical performance. We sought to establish (1) the construct validity of the ICSAD as an assessment tool in ultrasound-guided supraclavicular block by determining its ability to discriminate between operators of different experience level and (2) the concurrent validity of the ICSAD by correlating it with a task-specific checklist and a global rating scale. Methods: We compared 30 performances of ultrasound-guided supraclavicular block by junior residents with 30 performances by highly experienced consultant anesthesiologists. We also studied 10 anesthesiologists undertaking a 1-year regional anesthesia fellowship and compared a performance in their first month to one in their last 3 months. We used the ICSAD to measure 3 dexterity parameters during the scanning and needling phases of each block: time taken, number of movements, and path length traveled by each hand. Two blinded expert observers evaluated video recordings of each block using a 30-item task-specific checklist and a 7-item global rating scale. Results: Consultants (experts) performed significantly better than residents (novices) on all ICSAD parameters in both scanning and needling phases. Fellows demonstrated improvement in all ICSAD parameters between their early and late performance, reflecting their transition from novice to expert. The task-specific checklist and global rating scale were also highly discriminating between novice and expert performances. There was excellent correlation between all 3 measurement tools, thereby establishing their concurrent validity. Conclusions: The ICSAD is both valid and useful in assessing performance of ultrasound-guided supraclavicular block.
引用
收藏
页码:213 / 219
页数:7
相关论文
共 1 条
  • [1] Hand motion analysis for assessment of nursing competence in ultrasound-guided peripheral intravenous catheter placement
    Good, Ryan J.
    Rothman, Kelly K.
    Ackil, Daniel J.
    Kim, John S.
    Orsborn, Jonathan
    Kendall, John L.
    JOURNAL OF VASCULAR ACCESS, 2019, 20 (03): : 301 - 306