Anterior Chamber Depth Measurement in Phakic and Pseudophakic Eyes

被引:43
|
作者
Su, Po-Fang [1 ]
Lo, Andy Y. [1 ]
Hu, Chao-Yu [1 ]
Chang, Shu-Wen [1 ,2 ]
机构
[1] Far Eastern Mem Hosp, Dept Ophthalmol, Taipei 220, Taiwan
[2] Natl Taiwan Univ Hosp, Dept Ophthalmol, Taipei, Taiwan
关键词
anterior chamber depth; Pentacam; IOLMaster; A-scan ultrasonography; blue light-filtering IOLs;
D O I
10.1097/OPX.0b013e31818e8ceb
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To compare anterior chamber depth (ACD) measurements using two non-contact optical devices, Pentacam and IOLMaster, and a contact device, ultrasonic A-scan in phakic and pseudophakic eyes. Methods. Ninety phakic and 94 pseudophakic eyes were enrolled in this prospective Study. The difference between ACD measurements by the three devices was analyzed using the repeated-measures analysis of variance, and agreement among the three measurements was investigated. The accuracy of detecting the anterior lens surface of the intraocular lens (IOL) with or without blue-blocker was also assessed. Results. In phakic eyes, the Pentacam measured the deepest ACD with the smallest standard deviation (3.26 +/- 0.41, 3.20 +/- 0.45, and 3.12 +/- 0.44 mm measured by Pentacam, IOLMaster, and A-scan, respectively, p < 0.001). In contrast, the Pentacam measurement of ACD had the largest standard deviation in pseudophakic eyes (4.05 +/- 0.58, 4.06 +/- 0.46, and 3.81 +/- 0.41 mm by Pentacam, IOL-Master, and A-scan, respectively, p < 0.001). The Pentacam instrument failed to correctly identify the anterior lens surface in 26.4% of IOLs without blue-blocker and in 58.5% of blue light-filtering IOLs (p = 0.016). Manual correction of the Pentacam image and subsequent ACD measurement improved the agreement between Pentacam and the other two devices. After manual adjustment, the average ACD value increased, and the standard deviation decreased significantly (4.34 +/- 0.28 mm). Conclusions. ACD measurements by Pentacam, IOLMaster, and A-scan were in better agreement in phakic eyes when compared with pseudophakic eyes. In pseudophakic eyes, the 95% limits of agreements between Pentacam and IOLMaster as well as Pentacam and A-scan were unsatisfactory. IOLs with blue-blocker might interfere with ACD measurements. However, this error can be corrected manually in the Pentacam examination.
引用
收藏
页码:1193 / 1200
页数:8
相关论文
共 50 条
  • [1] Comparison of anterior chamber depth measurement methods in phakic and pseudophakic eyes
    Kriechbaum, K
    Findl, O
    Kiss, B
    Sacu, S
    Petternel, V
    Drexler, W
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (01): : 89 - 94
  • [2] Anterior chamber depth measurements in phakic and pseudophakic eyes: Pentacam versus ultrasound device
    Nemeth, Gabor
    Vajas, Attila
    Kolozsvari, Bence
    Berta, Andras
    Modis, Laszlo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (08): : 1331 - 1335
  • [3] Anterior Chamber Depth Measurement in Pseudophakic Eyes: A Comparison of Pentacam and Ultrasound
    Savini, Giacomo
    Olsen, Thomas
    Carbonara, Claudio
    Pazzaglia, Sebastiano
    Barboni, Piero
    Carbonelli, Michele
    Hoffer, Kenneth J.
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (05) : 341 - 347
  • [4] A comparison of anterior chamber depth in phakic and pseudophakic eyes following glaucoma filtering procedures.
    Aminlari, AA
    Rutherford, GEW
    Dailey, JR
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 4983 - 4983
  • [5] Pseudophakic anterior chamber depth measurement
    Cartwright, N. E. Knox
    Tole, D. M.
    EYE, 2009, 23 (11) : 2120 - 2120
  • [6] Pseudophakic anterior chamber depth measurement
    N E Knox Cartwright
    D M Tole
    Eye, 2009, 23 : 2120 - 2120
  • [7] Factors influencing anterior chamber depth in pseudophakic eyes
    An, Youngju
    Kang, Eun-Kyoung
    Joo, Choun-Ki
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [8] Agreement of phakic and pseudophakic anterior chamber depth measurements in IOLMaster and Pentacam
    Hamoudi, Hassan
    Christensen, Ulrik Correll
    la Cour, Morten
    ACTA OPHTHALMOLOGICA, 2018, 96 (03) : E403 - E403
  • [9] Reply: Pseudophakic anterior chamber depth measurement
    M A Nanavaty
    S M Raj
    V A Vasavada
    V A Vasavada
    A R Vasavada
    Eye, 2009, 23 : 2120 - 2120
  • [10] SHALLOW ANTERIOR-CHAMBER FOLLOWING TRABECULECTOMY SURGERY IN PHAKIC VERSUS PSEUDOPHAKIC EYES
    DAILEY, JR
    AMINLARI, A
    SASSANI, JW
    PARNES, RE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1419 - 1419