Anterior Chamber Depth Measurement in Phakic and Pseudophakic Eyes

被引:43
|
作者
Su, Po-Fang [1 ]
Lo, Andy Y. [1 ]
Hu, Chao-Yu [1 ]
Chang, Shu-Wen [1 ,2 ]
机构
[1] Far Eastern Mem Hosp, Dept Ophthalmol, Taipei 220, Taiwan
[2] Natl Taiwan Univ Hosp, Dept Ophthalmol, Taipei, Taiwan
关键词
anterior chamber depth; Pentacam; IOLMaster; A-scan ultrasonography; blue light-filtering IOLs;
D O I
10.1097/OPX.0b013e31818e8ceb
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To compare anterior chamber depth (ACD) measurements using two non-contact optical devices, Pentacam and IOLMaster, and a contact device, ultrasonic A-scan in phakic and pseudophakic eyes. Methods. Ninety phakic and 94 pseudophakic eyes were enrolled in this prospective Study. The difference between ACD measurements by the three devices was analyzed using the repeated-measures analysis of variance, and agreement among the three measurements was investigated. The accuracy of detecting the anterior lens surface of the intraocular lens (IOL) with or without blue-blocker was also assessed. Results. In phakic eyes, the Pentacam measured the deepest ACD with the smallest standard deviation (3.26 +/- 0.41, 3.20 +/- 0.45, and 3.12 +/- 0.44 mm measured by Pentacam, IOLMaster, and A-scan, respectively, p < 0.001). In contrast, the Pentacam measurement of ACD had the largest standard deviation in pseudophakic eyes (4.05 +/- 0.58, 4.06 +/- 0.46, and 3.81 +/- 0.41 mm by Pentacam, IOL-Master, and A-scan, respectively, p < 0.001). The Pentacam instrument failed to correctly identify the anterior lens surface in 26.4% of IOLs without blue-blocker and in 58.5% of blue light-filtering IOLs (p = 0.016). Manual correction of the Pentacam image and subsequent ACD measurement improved the agreement between Pentacam and the other two devices. After manual adjustment, the average ACD value increased, and the standard deviation decreased significantly (4.34 +/- 0.28 mm). Conclusions. ACD measurements by Pentacam, IOLMaster, and A-scan were in better agreement in phakic eyes when compared with pseudophakic eyes. In pseudophakic eyes, the 95% limits of agreements between Pentacam and IOLMaster as well as Pentacam and A-scan were unsatisfactory. IOLs with blue-blocker might interfere with ACD measurements. However, this error can be corrected manually in the Pentacam examination.
引用
收藏
页码:1193 / 1200
页数:8
相关论文
共 50 条
  • [41] Anterior chamber depth in eyes with central serous chorioretinopathy
    Oh, Jong-Hyun
    Oh, Jaeryung
    Choi, Yong-Min
    Kim, Seong-Woo
    Huh, Kuhl
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [42] Anterior chamber phakic lenses
    Nose, Walton
    Forseto, Adriana dos Santos
    REVISTA BRASILEIRA DE OFTALMOLOGIA, 2012, 71 (04) : 260 - 271
  • [43] Influence of anterior chamber depth and vault on anterior chamber angle morphology after phakic posterior chamber intraocular lens implantation
    Sanchez-Trancon, Angel
    Manito, Santiago Cerpa
    Sierra, Oscar Torrado
    Baptista, Antonio Manuel
    Serra, Pedro Miguel
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [44] PREDICTION OF PSEUDOPHAKIC ANTERIOR-CHAMBER DEPTH WITH THE NEWER IOL CALCULATION FORMULAS
    OLSEN, T
    OLESEN, H
    THIM, K
    CORYDON, L
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (03): : 280 - 285
  • [45] Diode Laser Cyclophotocoagulation in Pseudophakic and Phakic Eyes With Neovascular Glaucoma
    Offor, N.
    Chu, I.
    Khouri, A.
    Cohen, A.
    Fechtner, R.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [46] Selective laser trabeculoplasty in pseudophakic and phakic eyes:a prospective study
    Myrjam De Keyser
    Maya De Belder
    Veva De Groot
    International Journal of Ophthalmology, 2017, (04) : 593 - 598
  • [47] Selective laser trabeculoplasty in pseudophakic and phakic eyes: a prospective study
    De Keyser, Myrjam
    De Belder, Maya
    De Groot, Veva
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2017, 10 (04) : 593 - 598
  • [48] Cytokine profiles of phakic and pseudophakic eyes with primary retinal detachment
    Garweg, Justus G.
    Zandi, Souska
    Pfister, Isabel
    Rieben, Robert
    Skowronska, Magdalena
    Tappeiner, Christoph
    ACTA OPHTHALMOLOGICA, 2019, 97 (04) : E580 - E588
  • [49] Comparison of the Optical Image Quality in the Periphery of Phakic and Pseudophakic Eyes
    Jaeken, Bart
    Mirabet, Sandra
    Maria Marin, Jose
    Artal, Pablo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (05) : 3594 - 3599
  • [50] Progression of Age Related Maculopathy in Phakic Versus Pseudophakic Eyes
    Kovacevic, Damir
    Vuceric, Tamara Misljenovic
    Caljkusic-Mance, Tea