Anterior Chamber Depth Measurement in Phakic and Pseudophakic Eyes

被引:43
|
作者
Su, Po-Fang [1 ]
Lo, Andy Y. [1 ]
Hu, Chao-Yu [1 ]
Chang, Shu-Wen [1 ,2 ]
机构
[1] Far Eastern Mem Hosp, Dept Ophthalmol, Taipei 220, Taiwan
[2] Natl Taiwan Univ Hosp, Dept Ophthalmol, Taipei, Taiwan
关键词
anterior chamber depth; Pentacam; IOLMaster; A-scan ultrasonography; blue light-filtering IOLs;
D O I
10.1097/OPX.0b013e31818e8ceb
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To compare anterior chamber depth (ACD) measurements using two non-contact optical devices, Pentacam and IOLMaster, and a contact device, ultrasonic A-scan in phakic and pseudophakic eyes. Methods. Ninety phakic and 94 pseudophakic eyes were enrolled in this prospective Study. The difference between ACD measurements by the three devices was analyzed using the repeated-measures analysis of variance, and agreement among the three measurements was investigated. The accuracy of detecting the anterior lens surface of the intraocular lens (IOL) with or without blue-blocker was also assessed. Results. In phakic eyes, the Pentacam measured the deepest ACD with the smallest standard deviation (3.26 +/- 0.41, 3.20 +/- 0.45, and 3.12 +/- 0.44 mm measured by Pentacam, IOLMaster, and A-scan, respectively, p < 0.001). In contrast, the Pentacam measurement of ACD had the largest standard deviation in pseudophakic eyes (4.05 +/- 0.58, 4.06 +/- 0.46, and 3.81 +/- 0.41 mm by Pentacam, IOL-Master, and A-scan, respectively, p < 0.001). The Pentacam instrument failed to correctly identify the anterior lens surface in 26.4% of IOLs without blue-blocker and in 58.5% of blue light-filtering IOLs (p = 0.016). Manual correction of the Pentacam image and subsequent ACD measurement improved the agreement between Pentacam and the other two devices. After manual adjustment, the average ACD value increased, and the standard deviation decreased significantly (4.34 +/- 0.28 mm). Conclusions. ACD measurements by Pentacam, IOLMaster, and A-scan were in better agreement in phakic eyes when compared with pseudophakic eyes. In pseudophakic eyes, the 95% limits of agreements between Pentacam and IOLMaster as well as Pentacam and A-scan were unsatisfactory. IOLs with blue-blocker might interfere with ACD measurements. However, this error can be corrected manually in the Pentacam examination.
引用
收藏
页码:1193 / 1200
页数:8
相关论文
共 50 条
  • [21] Glare sensitivity in patients with phakic and pseudophakic eyes
    Eisenmann, D
    Jacobi, FK
    Dick, B
    Jacobi, KW
    Pabst, W
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1996, 208 (02) : 87 - 92
  • [22] The effect of Nd:YAGAG laser treatment of posterior capsule opacification on anterior chamber depth and refraction in pseudophakic eyes
    Khambhiphant, Bharkbhum
    Liumsirijarern, Chayata
    Saehout, Piyada
    CLINICAL OPHTHALMOLOGY, 2015, 9 : 557 - 561
  • [23] ANTERIOR-CHAMBER DEPTH IN EYES WITH PSEUDOEXFOLIATION
    BARTHOLOMEW, RS
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1980, 64 (05) : 322 - 323
  • [24] Endothelial changes in phakic eyes after anterior chamber lens implantation
    Eifrig, DE
    Peiffer, RL
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (10): : 1392 - 1392
  • [25] THE REMOVAL OF SILICONE OIL FROM THE ANTERIOR-CHAMBER IN PHAKIC EYES
    KIRKBY, GR
    GREGOR, ZJ
    ARCHIVES OF OPHTHALMOLOGY, 1987, 105 (11) : 1592 - 1592
  • [26] Assessment of midperipheral anterior chamber depth in patient with posterior chamber phakic intraocular lens
    Tenen, Abigail
    Roberts, Kate
    Sack, Julian
    Hodge, Chris
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (10): : 1611 - 1614
  • [27] Comparison of Anterior Segment Parameters Between Phakic and Pseudophakic Eyes of Subjects with Emmetropia and Degenerative Myopia
    Demir, Mehmet
    Akpolat, Cetin
    Arslan, Gurcan Dogukan
    Sendul, Yekta
    ACTA OPHTHALMOLOGICA, 2019, 97
  • [28] Comparability of anterior chamber depth measurements with partial coherence interferometry and optical low-coherence reflectometry in pseudophakic eyes
    Luft, Nikolaus
    Hirnschall, Nino
    Farrokhi, Sanaz
    Findl, Oliver
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (08): : 1678 - 1684
  • [29] Lens-thickness correlation with pseudophakic anterior chamber depth Reply
    Shammas, H. John
    Shammas, Maya C.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (04): : 646 - 647
  • [30] Efficacy of Selective Laser Trabeculoplasty in Phakic and Pseudophakic Eyes
    Seymenoglu, Goktug
    Baser, Esin F.
    JOURNAL OF GLAUCOMA, 2015, 24 (02) : 105 - 110