Comparability of anterior chamber depth measurements with partial coherence interferometry and optical low-coherence reflectometry in pseudophakic eyes

被引:6
|
作者
Luft, Nikolaus [1 ]
Hirnschall, Nino [1 ]
Farrokhi, Sanaz [1 ]
Findl, Oliver [1 ,2 ]
机构
[1] Hanusch Hosp, A Karl Landsteiner Inst, Vienna Inst Res Ocular Surg, A-1140 Vienna, Austria
[2] Moorfields Eye Hosp NHS Fdn Trust, London, England
来源
关键词
INTRAOCULAR-LENS POWER; CATARACT-SURGERY; PRECISION BIOMETRY; POSITION; TOMOGRAPHY; AGREEMENT; MOVEMENT; ACMASTER; SEGMENT; DESIGN;
D O I
10.1016/j.jcrs.2015.08.013
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess whether anterior chamber depth (ACD) measurements in pseudophakic eyes. obtained with partial coherence interferometry (PCI) and optical low-coherence reflectometry (OLCR) devices can be used interchangeably. SETTING: Vienna Institute for Research in Ocular Surgery, A Karl Landsteiner Institute, Hanusch Hospital, Vienna, Austria. DESIGN: Prospective case series. METHODS: The ACD measurements in 1 eye of each pseudophakic patient were performed with the PCI-based ACMaster device and the OLCR-based Lenstar LS900 device at least 1 day postoperatively. RESULTS: The study comprised 65 eyes of 65 patients with a mean age of 71.7 years +/- 9.0 (SD) (range 39 to 91 years). In 15 eyes, no valid ACD readings could be obtained with the OLCR device. No obvious reason for these measurement failures was identified; however, tear-film alterations shortly after surgery were suspected. No significant difference in the mean ACD in the remaining 50 eyes was found between PCI measurements (5019 +/- 660 mu m; range 4008 to 6181 mu m) and OLCR measurements (5015 +/- 663 mu m; range 4017 to 6163 mu m) (P = .06). Three (6%) of 50 measurements were not within the 95% limits of agreement in the Bland-Altman analysis. CONCLUSIONS: Pseudophakic ACD measurements with the PCI and OLCR devices can be used interchangeably. The OLCR device proved to be more user-friendly and faster; however, in a substantial number of eyes, no usable values were obtainable. (C) 2015 ASCRS and ESCRS
引用
收藏
页码:1678 / 1684
页数:7
相关论文
共 50 条
  • [1] Comparison of Anterior Segment Measurements with Optical Low-coherence Reflectometry and Partial-coherence Interferometry Optical Biometers
    Can, Ertugrul
    Duran, Mustafa
    Cetinkaya, Tugba
    Ariturk, Nursen
    [J]. MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2016, 23 (04) : 288 - 292
  • [2] Anterior chamber depth measurements in eyes with an accommodating intraocular lens Agreement between partial coherence interferometry and optical coherence tomography
    Cleary, Georgia
    Spalton, David J.
    Marshall, John
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (05): : 790 - 798
  • [3] Meta-analysis of optical low-coherence reflectometry versus partial coherence interferometry biometry
    Huang, Jinhai
    McAlinden, Colm
    Huang, Yingying
    Wen, Daizong
    Savini, Giacomo
    Tu, Ruixue
    Wang, Qinmei
    [J]. SCIENTIFIC REPORTS, 2017, 7 : 1 - 10
  • [4] Meta-analysis of optical low-coherence reflectometry versus partial coherence interferometry biometry
    Jinhai Huang
    Colm McAlinden
    Yingying Huang
    Daizong Wen
    Giacomo Savini
    Ruixue Tu
    Qinmei Wang
    [J]. Scientific Reports, 7
  • [5] Intrasession Repeatability of Biometric Measurements Obtained with a Low-Coherence Interferometry System in Pseudophakic Eyes
    Fukumitsu, Hideki
    Camps, Vicent J.
    Pinero, David P.
    [J]. CURRENT EYE RESEARCH, 2020, 45 (02) : 221 - 226
  • [6] Evaluation of the Effect of Cycloplegia on Anterior Chamber Depth in Cataract Patients Using Optical Low-Coherence Reflectometry
    Avdagic, Ema
    Lazzaro, Douglas R.
    [J]. EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2018, 44 : S59 - S61
  • [7] Optical low-coherence reflectometry for nondestructive process measurements
    Randall, SL
    Brodsky, AM
    Burgess, LW
    Green, RL
    [J]. REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 22A AND 22B, 2003, 20 : 1713 - 1720
  • [8] Noise in optical low-coherence reflectometry
    Takada, K
    [J]. IEEE JOURNAL OF QUANTUM ELECTRONICS, 1998, 34 (07) : 1098 - 1108
  • [9] High-speed measurements in optical low-coherence reflectometry
    Szydlo, J
    Bleuler, H
    Walti, R
    Salathe, RP
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 1998, 9 (08) : 1159 - 1162
  • [10] Systemic Tamsulosin Use and Anterior Chamber Depth by Partial Coherence Interferometry
    Carroll, Joy
    Lindsey, Jennifer
    Chomsky, Amy
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)