Anterior chamber depth measurements in phakic and pseudophakic eyes: Pentacam versus ultrasound device

被引:57
|
作者
Nemeth, Gabor [1 ]
Vajas, Attila [1 ]
Kolozsvari, Bence [1 ]
Berta, Andras [1 ]
Modis, Laszlo [1 ]
机构
[1] Univ Debrecen, Med & Hlth Sci Ctr, Dept Ophthalmol, H-4012 Debrecen, Hungary
来源
关键词
D O I
10.1016/j.jcrs.2006.02.057
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare anterior chamber depth (ACD) measurements with a new optical device with those taken with a standard ultrasound (US) device in emmetropic phakic and pseudophakic eyes. SETTING: Department of Ophthalmology, Medical Health and Science Center, University of Debrecen, Debrecen, Hungary. METHODS: Forty-two phakic and 42 pseudophakic patients with normal axial lengths (mean 22.91 mm +/- 1.21 [SD]) were enrolled in the study. The ACD was measured 3 times with Scheimpflug-based Pentacam (Oculus) and then 3 times with a standard A-scan US device (AL-2000, Tomey). The data were then analyzed. RESULTS: In the phakic group, the mean ACID was 2.87 +/- 0.4 mm with the Pentacam and 2.89 +/- 0.49 mm with ultrasound A-scan (US) (P =.84). In the pseudophakic group, the mean ACD was 3.41 +/- 0.28 mm and 3.97 +/- 0.45 mm, respectively (P<.001). The correlation between measurements was significant in both the phakic and pseudophakic groups (r =.547/P<.001 and r =.404/P =.01, respectively). CONCLUSIONS: In phakic eyes, ACD measured with the Pentacam and with US was the same. However, in pseudophakic eyes, the difference was significantly lower when the ACD was measured with the Pentacam. Therefore, in pseudophakic patients, further evaluation of ACD data with the Scheimpflug-based system is necessary.
引用
收藏
页码:1331 / 1335
页数:5
相关论文
共 50 条
  • [1] Agreement of phakic and pseudophakic anterior chamber depth measurements in IOLMaster and Pentacam
    Hamoudi, Hassan
    Christensen, Ulrik Correll
    la Cour, Morten
    ACTA OPHTHALMOLOGICA, 2018, 96 (03) : E403 - E403
  • [2] Anterior Chamber Depth Measurement in Pseudophakic Eyes: A Comparison of Pentacam and Ultrasound
    Savini, Giacomo
    Olsen, Thomas
    Carbonara, Claudio
    Pazzaglia, Sebastiano
    Barboni, Piero
    Carbonelli, Michele
    Hoffer, Kenneth J.
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (05) : 341 - 347
  • [3] Anterior Chamber Depth Measurement in Phakic and Pseudophakic Eyes
    Su, Po-Fang
    Lo, Andy Y.
    Hu, Chao-Yu
    Chang, Shu-Wen
    OPTOMETRY AND VISION SCIENCE, 2008, 85 (12) : 1193 - 1200
  • [4] Repeatability, reproducibility, and agreement of central anterior chamber depth measurements in pseudophakic and phakic eyes: Optical coherence tomography versus ultrasound biomicroscopy
    Zhang, Qi
    Jin, Wanqing
    Wang, Qinmei
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (06): : 941 - 946
  • [5] Comparison of anterior chamber depth measurement methods in phakic and pseudophakic eyes
    Kriechbaum, K
    Findl, O
    Kiss, B
    Sacu, S
    Petternel, V
    Drexler, W
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (01): : 89 - 94
  • [6] SHALLOW ANTERIOR-CHAMBER FOLLOWING TRABECULECTOMY SURGERY IN PHAKIC VERSUS PSEUDOPHAKIC EYES
    DAILEY, JR
    AMINLARI, A
    SASSANI, JW
    PARNES, RE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1419 - 1419
  • [7] A comparison of anterior chamber depth in phakic and pseudophakic eyes following glaucoma filtering procedures.
    Aminlari, AA
    Rutherford, GEW
    Dailey, JR
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 4983 - 4983
  • [8] Factors influencing anterior chamber depth in pseudophakic eyes
    An, Youngju
    Kang, Eun-Kyoung
    Joo, Choun-Ki
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [9] Corneal radii and anterior chamber depth measurements using the IOLMaster versus the Pentacam
    Reuland, Mirjarn S.
    Reuland, Andreas J.
    Nishi, Yutaro
    Auffarth, Gerd U.
    JOURNAL OF REFRACTIVE SURGERY, 2007, 23 (04) : 368 - 373
  • [10] ULTRASOUND BIOMICROSCOPY IN ANTERIOR-CHAMBER PHAKIC EYES IMPLANTS
    ALLEMANN, N
    CHAMON, W
    VANZELLA, LL
    NOSE, RM
    NOSE, W
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S797 - S797