Anterior chamber depth measurements in phakic and pseudophakic eyes: Pentacam versus ultrasound device

被引:57
|
作者
Nemeth, Gabor [1 ]
Vajas, Attila [1 ]
Kolozsvari, Bence [1 ]
Berta, Andras [1 ]
Modis, Laszlo [1 ]
机构
[1] Univ Debrecen, Med & Hlth Sci Ctr, Dept Ophthalmol, H-4012 Debrecen, Hungary
来源
关键词
D O I
10.1016/j.jcrs.2006.02.057
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare anterior chamber depth (ACD) measurements with a new optical device with those taken with a standard ultrasound (US) device in emmetropic phakic and pseudophakic eyes. SETTING: Department of Ophthalmology, Medical Health and Science Center, University of Debrecen, Debrecen, Hungary. METHODS: Forty-two phakic and 42 pseudophakic patients with normal axial lengths (mean 22.91 mm +/- 1.21 [SD]) were enrolled in the study. The ACD was measured 3 times with Scheimpflug-based Pentacam (Oculus) and then 3 times with a standard A-scan US device (AL-2000, Tomey). The data were then analyzed. RESULTS: In the phakic group, the mean ACID was 2.87 +/- 0.4 mm with the Pentacam and 2.89 +/- 0.49 mm with ultrasound A-scan (US) (P =.84). In the pseudophakic group, the mean ACD was 3.41 +/- 0.28 mm and 3.97 +/- 0.45 mm, respectively (P<.001). The correlation between measurements was significant in both the phakic and pseudophakic groups (r =.547/P<.001 and r =.404/P =.01, respectively). CONCLUSIONS: In phakic eyes, ACD measured with the Pentacam and with US was the same. However, in pseudophakic eyes, the difference was significantly lower when the ACD was measured with the Pentacam. Therefore, in pseudophakic patients, further evaluation of ACD data with the Scheimpflug-based system is necessary.
引用
收藏
页码:1331 / 1335
页数:5
相关论文
共 50 条
  • [41] The Effect of Ocular Massage on Intraocular Pressure in Phakic eyes versus Pseudophakic eyes after Intravitreal Injections
    Lazar, David
    Karpinski, Aryn C.
    Weiss, Jayne S.
    Rao, Aravinda
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [42] Ultrasound biomicroscopy of Baikoff anterior chamber phakic intraocular lenses
    Saragoussi, JJ
    Puech, M
    Assouline, M
    Berges, O
    Renard, G
    Pouliquen, YJM
    JOURNAL OF REFRACTIVE SURGERY, 1997, 13 (02): : 135 - 141
  • [43] Comparison of central corneal thickness and anterior chamber depth measurements using three imaging technologies in normal eyes and after phakic intraocular lens implantation
    Doors, Muriel
    Cruysberg, Lars P. J.
    Berendschot, Tos T. J. M.
    de Brabander, John
    Verbakel, Frenne
    Webers, Carroll A. B.
    Nuijts, Rudy M. M. A.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2009, 247 (08) : 1139 - 1146
  • [44] Comparison of central corneal thickness and anterior chamber depth measurements using three imaging technologies in normal eyes and after phakic intraocular lens implantation
    Muriël Doors
    Lars P. J. Cruysberg
    Tos T. J. M. Berendschot
    John de Brabander
    Frenne Verbakel
    Carroll A. B. Webers
    Rudy M. M. A. Nuijts
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2009, 247 : 1139 - 1146
  • [45] Assessment of midperipheral anterior chamber depth in patient with posterior chamber phakic intraocular lens
    Tenen, Abigail
    Roberts, Kate
    Sack, Julian
    Hodge, Chris
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (10): : 1611 - 1614
  • [46] Comparison of Anterior Segment Parameters Between Phakic and Pseudophakic Eyes of Subjects with Emmetropia and Degenerative Myopia
    Demir, Mehmet
    Akpolat, Cetin
    Arslan, Gurcan Dogukan
    Sendul, Yekta
    ACTA OPHTHALMOLOGICA, 2019, 97
  • [47] Alteration of anterior chamber in 81 glaucomatous eyes using Pentacam Scheimpflug system
    Zou, Xuan
    Duan, Xuan-Chu
    Zhong, Qian
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2010, 3 (04) : 349 - 351
  • [48] Lens-thickness correlation with pseudophakic anterior chamber depth Reply
    Shammas, H. John
    Shammas, Maya C.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (04): : 646 - 647
  • [49] Central Corneal Thickness, Anterior Chamber Depth, and Pupil Diameter Measurements Using Visante OCT, Orbscan, and Pentacam
    Yazici, Ahmet Taylan
    Bozkurt, Ercument
    Alagoz, Cengiz
    Alagoz, Nese
    Pekel, Gokhan
    Kaya, Vedat
    Yilmaz, Omer Faruk
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (02) : 127 - 133
  • [50] Long-term Outcomes of Mitomycin C Trabeculectomy for Exfoliative Glaucoma in Phakic Eyes versus Pseudophakic Eyes
    Cha, Sooncheol
    Moon, Cheolwon
    Gu, Wonmo
    Son, Junhyuk
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)