Anterior chamber depth measurements in phakic and pseudophakic eyes: Pentacam versus ultrasound device

被引:57
|
作者
Nemeth, Gabor [1 ]
Vajas, Attila [1 ]
Kolozsvari, Bence [1 ]
Berta, Andras [1 ]
Modis, Laszlo [1 ]
机构
[1] Univ Debrecen, Med & Hlth Sci Ctr, Dept Ophthalmol, H-4012 Debrecen, Hungary
来源
关键词
D O I
10.1016/j.jcrs.2006.02.057
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare anterior chamber depth (ACD) measurements with a new optical device with those taken with a standard ultrasound (US) device in emmetropic phakic and pseudophakic eyes. SETTING: Department of Ophthalmology, Medical Health and Science Center, University of Debrecen, Debrecen, Hungary. METHODS: Forty-two phakic and 42 pseudophakic patients with normal axial lengths (mean 22.91 mm +/- 1.21 [SD]) were enrolled in the study. The ACD was measured 3 times with Scheimpflug-based Pentacam (Oculus) and then 3 times with a standard A-scan US device (AL-2000, Tomey). The data were then analyzed. RESULTS: In the phakic group, the mean ACID was 2.87 +/- 0.4 mm with the Pentacam and 2.89 +/- 0.49 mm with ultrasound A-scan (US) (P =.84). In the pseudophakic group, the mean ACD was 3.41 +/- 0.28 mm and 3.97 +/- 0.45 mm, respectively (P<.001). The correlation between measurements was significant in both the phakic and pseudophakic groups (r =.547/P<.001 and r =.404/P =.01, respectively). CONCLUSIONS: In phakic eyes, ACD measured with the Pentacam and with US was the same. However, in pseudophakic eyes, the difference was significantly lower when the ACD was measured with the Pentacam. Therefore, in pseudophakic patients, further evaluation of ACD data with the Scheimpflug-based system is necessary.
引用
收藏
页码:1331 / 1335
页数:5
相关论文
共 50 条
  • [31] Posterior Chamber Phakic Intraocular Lens Implantation in Eyes with an Anterior Chamber Depth of Less Than 3 mm: A Multicenter Study
    Kamiya, Kazutaka
    Shimizu, Kimiya
    Igarashi, Akihito
    Kitazawa, Yoshihiro
    Kojima, Takashi
    Nakamura, Tomoaki
    Ichikawa, Kazuo
    SCIENTIFIC REPORTS, 2018, 8
  • [32] Lens-thickness correlation with pseudophakic anterior chamber depth
    Galvis, Virgilio
    Tello, Alejandro
    Frederick, Gabriel A.
    Serrano, Andres
    Camacho, Paul A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (04): : 645 - 646
  • [33] Calculation of ocular magnification in phakic and pseudophakic eyes based on anterior segment OCT data
    Langenbucher, Achim
    Szentmary, Nora
    Leydolt, Christina
    Cayless, Alan
    Schwarzenbacher, Luca
    Nagy, Zoltan Zsolt
    Menapace, Rupert
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2021, 41 (04) : 831 - 841
  • [34] Precision of a new device for biometric measurements in pseudophakic eyes
    Hildebrandt, A. L.
    Auffarth, G. U.
    Holzer, M. P.
    OPHTHALMOLOGE, 2011, 108 (08): : 739 - 744
  • [35] Intrasubject Repeatability and Interdevice Agreement of Anterior Chamber Depth Measurements by Orbscan and Pentacam in Different Grades of Keratoconus
    Hashemi, Hassan
    Asharlous, Amir
    Amiri, Mohammad Aghazadeh
    Yekta, Abbasali
    Ramin, Shahroukh
    Taheri, Azadeh
    Aghamirsalim, Mohamadreza
    Khabazkhoob, Mehdi
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2019, 45 (01): : 51 - 54
  • [36] The effect of Nd:YAGAG laser treatment of posterior capsule opacification on anterior chamber depth and refraction in pseudophakic eyes
    Khambhiphant, Bharkbhum
    Liumsirijarern, Chayata
    Saehout, Piyada
    CLINICAL OPHTHALMOLOGY, 2015, 9 : 557 - 561
  • [37] ANTERIOR-CHAMBER DEPTH IN EYES WITH PSEUDOEXFOLIATION
    BARTHOLOMEW, RS
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1980, 64 (05) : 322 - 323
  • [38] Anterior chamber measurements using Pentacam rotating Scheimpflug camera
    Rabsilber, TM
    Khoramnia, R
    Auffarth, GU
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (03): : 456 - 459
  • [39] Endothelial changes in phakic eyes after anterior chamber lens implantation
    Eifrig, DE
    Peiffer, RL
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (10): : 1392 - 1392
  • [40] THE REMOVAL OF SILICONE OIL FROM THE ANTERIOR-CHAMBER IN PHAKIC EYES
    KIRKBY, GR
    GREGOR, ZJ
    ARCHIVES OF OPHTHALMOLOGY, 1987, 105 (11) : 1592 - 1592