Monitoring of hydrogen sulfide via substrate-integrated hollow waveguide mid-infrared sensors in real-time

被引:74
|
作者
da Silveira Petruci, Joao Flavio [1 ,2 ]
Fortes, Paula Regina [2 ,3 ]
Kokoric, Vjekoslav [2 ]
Wilk, Andreas [2 ]
Raimundo, Ivo Milton, Jr. [3 ]
Cardoso, Arnaldo Alves [1 ]
Mizaikoff, Boris [2 ]
机构
[1] Sao Paulo State Univ, Dept Analyt Chem, UNESP, BR-14800970 Araraquara, SP, Brazil
[2] Univ Ulm, Inst Analyt & Bioanalyt Chem, D-89081 Ulm, Germany
[3] Univ Estadual Campinas, Dept Analyt Chem, UNICAMP, Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
GAS; SYSTEM;
D O I
10.1039/c3an01793a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hydrogen sulfide is a highly corrosive, harmful, and toxic gas produced under anaerobic conditions within industrial processes or in natural environments, and plays an important role in the sulfur cycle. According to the U.S. Occupational Safety and Health Administration (OSHA), the permissible exposure limit (during 8 hours) is 10 ppm. Concentrations of 20 ppm are the threshold for critical health issues. In workplace environments with human subjects frequently exposed to H2S, e. g., during petroleum extraction and refining, real-time monitoring of exposure levels is mandatory. Sensors based on electrochemical measurement principles, semiconducting metal-oxides, taking advantage of their optical properties, have been described for H2S monitoring. However, extended response times, limited selectivity, and bulkiness of the instrumentation are common disadvantages of the sensing techniques reported to date. Here, we describe for the first time usage of a new generation of compact gas cells, i.e., so-called substrate-integrated hollow waveguides (iHWGs), combined with a compact Fourier transform infrared (FTIR) spectrometer for advanced gas sensing of H2S. The principle of detection is based on the immediate UV-assisted conversion of the rather weak IR-absorber H2S into much more pronounced and distinctively responding SO2. A calibration was established in the range of 10-100 ppm with a limit of detection (LOD) at 3 ppm, which is suitable for occupational health monitoring purposes. The developed sensing scheme provides an analytical response time of less than 60 seconds. Considering the substantial potential for miniaturization using e. g., a dedicated quantum cascade laser (QCL) in lieu of the FTIR spectrometer, the developed sensing approach may be evolved into a hand-held instrument, which may be tailored to a variety of applications ranging from environmental monitoring to workplace safety surveillance, process analysis and clinical diagnostics, e. g., breath analysis.
引用
收藏
页码:198 / 203
页数:6
相关论文
共 50 条
  • [41] Real-time and non-destructive hydrocarbon gas sensing using mid-infrared integrated photonic circuits
    Jin, Tiening
    Zhou, Junchao
    Lin, Pao Tai
    RSC ADVANCES, 2020, 10 (13) : 7452 - 7459
  • [42] Real-Time Monitoring of Transferrin-Induced Endocytic Vesicle Formation by Mid-Infrared Surface Plasmon Resonance
    Yashunsky, Victor
    Shimron, Simcha
    Lirtsman, Vladislav
    Weiss, Aryeh M.
    Melamed-Book, Naomi
    Golosovsky, Michael
    Davidov, Dan
    Aroeti, Benjamin
    BIOPHYSICAL JOURNAL, 2009, 97 (04) : 1003 - 1012
  • [43] Real-time in situ monitoring of freely suspended and immobilized cell cultures based on mid-infrared spectroscopic measurements
    Rhiel, M
    Ducommun, P
    Bolzonella, I
    Marison, I
    von Stockar, U
    BIOTECHNOLOGY AND BIOENGINEERING, 2002, 77 (02) : 174 - 185
  • [44] Real-time monitoring of ethane in human breath using mid-infrared cavity leak-out spectroscopy
    H. Dahnke
    D. Kleine
    P. Hering
    M. Mürtz
    Applied Physics B, 2001, 72 : 971 - 975
  • [45] Real-time high-resolution mid-infrared optical coherence tomography
    Israelsen, Niels M.
    Petersen, Christian R.
    Barh, Ajanta
    Jain, Deepak
    Jensen, Mikkel
    Hannesschlaeger, Guenther
    Tidemand-Lichtenberg, Peter
    Pedersen, Christian
    Podoleanu, Adrian
    Bang, Ole
    LIGHT-SCIENCE & APPLICATIONS, 2019, 8 (1)
  • [46] Real-time high-resolution mid-infrared optical coherence tomography
    Niels M. Israelsen
    Christian R. Petersen
    Ajanta Barh
    Deepak Jain
    Mikkel Jensen
    Günther Hannesschläger
    Peter Tidemand-Lichtenberg
    Christian Pedersen
    Adrian Podoleanu
    Ole Bang
    Light: Science & Applications, 8
  • [47] Real-Time Gas Mixture Analysis Using Mid-Infrared Membrane Microcavities
    Jin, Tiening
    Zhou, Junchao
    Wang, Zelun
    Gutierrez-Osuna, Ricardo
    Ahn, Charles
    Hwang, Wonjun
    Park, Ken
    Lin, Pao Tai
    ANALYTICAL CHEMISTRY, 2018, 90 (07) : 4348 - 4353
  • [48] Real-Time Acetone Vapor Detection Using Mid-Infrared Nanoporous Membrane
    Lin, Zhihai
    Caruso, Austin
    Makela, Megan
    Lin, Pao Tai
    IEEE SENSORS JOURNAL, 2022, 22 (14) : 14038 - 14043
  • [49] A Mid-Infrared Fiber-Coupled QEPAS Nitric Oxide Sensor for Real-Time Engine Exhaust Monitoring
    Shi, Chao
    Wang, Dien
    Wang, Zhen
    Ma, Liuhao
    Wang, Qiang
    Xu, Ke
    Chen, Shih-Chi
    Ren, Wei
    IEEE SENSORS JOURNAL, 2017, 17 (22) : 7418 - 7424
  • [50] Real-time monitoring of ethane in human breath using mid-infrared cavity leak-out spectroscopy
    Dahnke, H
    Kleine, D
    Hering, P
    Mürtz, M
    APPLIED PHYSICS B-LASERS AND OPTICS, 2001, 72 (08): : 971 - 975