Monitoring of hydrogen sulfide via substrate-integrated hollow waveguide mid-infrared sensors in real-time

被引:74
|
作者
da Silveira Petruci, Joao Flavio [1 ,2 ]
Fortes, Paula Regina [2 ,3 ]
Kokoric, Vjekoslav [2 ]
Wilk, Andreas [2 ]
Raimundo, Ivo Milton, Jr. [3 ]
Cardoso, Arnaldo Alves [1 ]
Mizaikoff, Boris [2 ]
机构
[1] Sao Paulo State Univ, Dept Analyt Chem, UNESP, BR-14800970 Araraquara, SP, Brazil
[2] Univ Ulm, Inst Analyt & Bioanalyt Chem, D-89081 Ulm, Germany
[3] Univ Estadual Campinas, Dept Analyt Chem, UNICAMP, Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
GAS; SYSTEM;
D O I
10.1039/c3an01793a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hydrogen sulfide is a highly corrosive, harmful, and toxic gas produced under anaerobic conditions within industrial processes or in natural environments, and plays an important role in the sulfur cycle. According to the U.S. Occupational Safety and Health Administration (OSHA), the permissible exposure limit (during 8 hours) is 10 ppm. Concentrations of 20 ppm are the threshold for critical health issues. In workplace environments with human subjects frequently exposed to H2S, e. g., during petroleum extraction and refining, real-time monitoring of exposure levels is mandatory. Sensors based on electrochemical measurement principles, semiconducting metal-oxides, taking advantage of their optical properties, have been described for H2S monitoring. However, extended response times, limited selectivity, and bulkiness of the instrumentation are common disadvantages of the sensing techniques reported to date. Here, we describe for the first time usage of a new generation of compact gas cells, i.e., so-called substrate-integrated hollow waveguides (iHWGs), combined with a compact Fourier transform infrared (FTIR) spectrometer for advanced gas sensing of H2S. The principle of detection is based on the immediate UV-assisted conversion of the rather weak IR-absorber H2S into much more pronounced and distinctively responding SO2. A calibration was established in the range of 10-100 ppm with a limit of detection (LOD) at 3 ppm, which is suitable for occupational health monitoring purposes. The developed sensing scheme provides an analytical response time of less than 60 seconds. Considering the substantial potential for miniaturization using e. g., a dedicated quantum cascade laser (QCL) in lieu of the FTIR spectrometer, the developed sensing approach may be evolved into a hand-held instrument, which may be tailored to a variety of applications ranging from environmental monitoring to workplace safety surveillance, process analysis and clinical diagnostics, e. g., breath analysis.
引用
收藏
页码:198 / 203
页数:6
相关论文
共 50 条
  • [11] Real-time monitoring of nitrile biotransformations by mid-infrared spectroscopy
    Dadd, MR
    Sharp, DCA
    Pettman, AJ
    Knowles, CJ
    JOURNAL OF MICROBIOLOGICAL METHODS, 2000, 41 (01) : 69 - 75
  • [12] Determining the Partial Pressure of Volatile Components via Substrate-Integrated Hollow Waveguide Infrared Spectroscopy with Integrated Microfluidics
    Kokoric, Vjekoslav
    Theisen, Johannes
    Wilk, Andreas
    Penisson, Christophe
    Bernard, Gabriel
    Mizaikoff, Boris
    Gabriel, Jean-Christophe P.
    ANALYTICAL CHEMISTRY, 2018, 90 (07) : 4445 - 4451
  • [13] Real-Time Exhaled CO2 Gas Measurement Using a Mid-Infrared Hollow Waveguide Fiber
    Ma Shuai
    Wu Tao
    Sun Chenglin
    Zhou Tao
    He Xingdao
    ACTA OPTICA SINICA, 2020, 40 (11)
  • [14] Monitoring Ozone Using Portable Substrate-Integrated Hollow Waveguide-Based Absorbance Sensors in the Ultraviolet Range
    Barreto, Diandra Nunes
    Silva, Weida Rodrigues
    Mizaikoff, Boris
    Petruci, Joao Flavio da Silveira
    ACS MEASUREMENT SCIENCE AU, 2021, 2 (01): : 39 - 45
  • [15] Mid-infrared spectroscopy as a tool for real-time monitoring of ethanol absorption in glycols
    Rodrigues, Kaio C. S.
    Veloso, Ivan I. K.
    Ribeiro, Marcelo P. A.
    Cruz, Antonio J. G.
    Badino, Alberto C.
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2021, 99 (01): : 401 - 409
  • [16] iHWG-MOX: A Hybrid Breath Analysis System via the Combination of Substrate-Integrated Hollow Waveguide Infrared Spectroscopy with Metal Oxide Gas Sensors
    Gloeckler, Johannes
    Jaeschke, Carsten
    Kocaoez, Yusuf
    Kokoric, Vjekoslav
    Tuetuencue, Erhan
    Mitrovics, Jan
    Mizaikoff, Boris
    ACS SENSORS, 2020, 5 (04): : 1033 - 1039
  • [17] Toward on-chip mid-infrared chem/bio sensors using quantum cascade lasers and substrate-integrated semiconductor waveguides
    Wang, X.
    Sieger, M.
    Mizaikoff, B.
    QUANTUM SENSING AND NANOPHOTONIC DEVICES X, 2013, 8631
  • [18] Real-time mid-infrared imaging of living microorganisms
    Haase, Katharina
    Kroeger-Lui, Niels
    Pucci, Annemarie
    Schoenhals, Arthur
    Petrich, Wolfgang
    JOURNAL OF BIOPHOTONICS, 2016, 9 (1-2) : 61 - 66
  • [19] Real-time monitoring of the stable free radical polymerization of styrene via in-situ mid-infrared spectroscopy
    Pasquale, AJ
    Long, TE
    MACROMOLECULES, 1999, 32 (23) : 7954 - 7957
  • [20] Real-time bioprocess monitoring using a mid-infrared fibre-optic sensor
    Alimagham, Farah
    Winterburn, James
    Dolman, Ben
    Domingues, Patrícia Maia
    Everest, Francesca
    Platkov, Max
    Basov, Svetlana
    Izakson, Gregory
    Katzir, Abraham
    Elliott, Stephen R.
    Hutter, Tanya
    Biochemical Engineering Journal, 2021, 167