Monitoring of hydrogen sulfide via substrate-integrated hollow waveguide mid-infrared sensors in real-time

被引:74
|
作者
da Silveira Petruci, Joao Flavio [1 ,2 ]
Fortes, Paula Regina [2 ,3 ]
Kokoric, Vjekoslav [2 ]
Wilk, Andreas [2 ]
Raimundo, Ivo Milton, Jr. [3 ]
Cardoso, Arnaldo Alves [1 ]
Mizaikoff, Boris [2 ]
机构
[1] Sao Paulo State Univ, Dept Analyt Chem, UNESP, BR-14800970 Araraquara, SP, Brazil
[2] Univ Ulm, Inst Analyt & Bioanalyt Chem, D-89081 Ulm, Germany
[3] Univ Estadual Campinas, Dept Analyt Chem, UNICAMP, Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
GAS; SYSTEM;
D O I
10.1039/c3an01793a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hydrogen sulfide is a highly corrosive, harmful, and toxic gas produced under anaerobic conditions within industrial processes or in natural environments, and plays an important role in the sulfur cycle. According to the U.S. Occupational Safety and Health Administration (OSHA), the permissible exposure limit (during 8 hours) is 10 ppm. Concentrations of 20 ppm are the threshold for critical health issues. In workplace environments with human subjects frequently exposed to H2S, e. g., during petroleum extraction and refining, real-time monitoring of exposure levels is mandatory. Sensors based on electrochemical measurement principles, semiconducting metal-oxides, taking advantage of their optical properties, have been described for H2S monitoring. However, extended response times, limited selectivity, and bulkiness of the instrumentation are common disadvantages of the sensing techniques reported to date. Here, we describe for the first time usage of a new generation of compact gas cells, i.e., so-called substrate-integrated hollow waveguides (iHWGs), combined with a compact Fourier transform infrared (FTIR) spectrometer for advanced gas sensing of H2S. The principle of detection is based on the immediate UV-assisted conversion of the rather weak IR-absorber H2S into much more pronounced and distinctively responding SO2. A calibration was established in the range of 10-100 ppm with a limit of detection (LOD) at 3 ppm, which is suitable for occupational health monitoring purposes. The developed sensing scheme provides an analytical response time of less than 60 seconds. Considering the substantial potential for miniaturization using e. g., a dedicated quantum cascade laser (QCL) in lieu of the FTIR spectrometer, the developed sensing approach may be evolved into a hand-held instrument, which may be tailored to a variety of applications ranging from environmental monitoring to workplace safety surveillance, process analysis and clinical diagnostics, e. g., breath analysis.
引用
收藏
页码:198 / 203
页数:6
相关论文
共 50 条
  • [31] Methodology for real-time, multianalyte monitoring of fermentations using an in-situ mid-infrared sensor
    Kornmann, H
    Rhiel, M
    Cannizzaro, C
    Marison, I
    von Stockar, U
    BIOTECHNOLOGY AND BIOENGINEERING, 2003, 82 (06) : 702 - 709
  • [32] Real-Time Monitoring of 13C- and 18O-Isotopes of Human Breath CO2 Using a Mid-Infrared Hollow Waveguide Gas Sensor
    Zhou, Tao
    Wu, Tao
    Wu, Qiang
    Chen, Weidong
    Wu, Mingwei
    Ye, Chenwen
    He, Xingdao
    ANALYTICAL CHEMISTRY, 2020, 92 (19) : 12943 - 12949
  • [33] Mid-Infrared Trace Gas Analysis with Single-Pass Fourier Transform Infrared Hollow Waveguide Gas Sensors
    Kim, Seong-Soo
    Menegazzo, Nicola
    Young, Christina
    Chan, James
    Carter, Chance
    Mizaikoff, Boris
    APPLIED SPECTROSCOPY, 2009, 63 (03) : 331 - 337
  • [34] Real-time isotopic methane detection using mid-infrared spectroscopy
    Yang, Jinghao
    Zhou, Junchao
    Lin, Pao Tai
    APPLIED OPTICS, 2020, 59 (34) : 10801 - 10807
  • [35] Mid-infrared Photonic Chips for Real-time Gas Mixture Analysis
    Jin, Tiening
    Lin, Pao Tai
    2018 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2018,
  • [36] Temperature Influence in Real-Time Monitoring of Fed-Batch Ethanol Fermentation by Mid-Infrared Spectroscopy
    Veloso, Ivan I. K.
    Rodrigues, Kaio C. S.
    Ribeiro, Marcelo P. A.
    Cruz, Antonio J. G.
    Badino, Alberto C.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2020, 59 (41) : 18425 - 18433
  • [37] Real-time analyte monitoring of a fungal fermentation, at pilot scale, using in situ mid-infrared spectroscopy
    Pollard D.J.
    Buccino R.
    Connors N.C.
    Kirschner T.F.
    Olewinski R.C.
    Saini K.
    Salmon P.M.
    Bioprocess and Biosystems Engineering, 2001, 24 (1) : 13 - 24
  • [38] Real-time analyte monitoring of a fungal fermentation, at pilot scale, using in situ mid-infrared spectroscopy
    Pollard, DJ
    Buccino, R
    Connors, NC
    Kirschner, TF
    Olewinski, RC
    Saini, K
    Salmon, PM
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2001, 24 (01) : 13 - 24
  • [39] Real-Time and Simultaneous Monitoring of NO, NO2, and N2O Using Substrate-Integrated Hollow Waveguides Coupled to a Compact Fourier Transform Infrared (FT-IR) Spectrometer
    da Silveira Petruci, Joao Flavio
    Tuetuencue, Erhan
    Cardoso, Arnaldo Alves
    Mizaikoff, Boris
    APPLIED SPECTROSCOPY, 2019, 73 (01) : 98 - 103
  • [40] Comparison of Raman and Mid-Infrared Spectroscopy for Real-Time Monitoring of Yeast Fermentations: A Proof-of-Concept for Multi-Channel Photometric Sensors
    Schalk, Robert
    Heintz, Annabell
    Braun, Frank
    Iacono, Giuseppe
    Raedle, Matthias
    Gretz, Norbert
    Methner, Frank-Juergen
    Beuermann, Thomas
    APPLIED SCIENCES-BASEL, 2019, 9 (12):