Methodology for real-time, multianalyte monitoring of fermentations using an in-situ mid-infrared sensor

被引:45
|
作者
Kornmann, H [1 ]
Rhiel, M [1 ]
Cannizzaro, C [1 ]
Marison, I [1 ]
von Stockar, U [1 ]
机构
[1] Swiss Fed Inst Technol, EPFL, Lab Chem & Biol Engn, CH-1015 Lausanne, Switzerland
关键词
mid-infrared; spectroscopy; on-line; monitoring; partial least squares; multivariate calibration; exopolysaccharide; Gluconacetobacter xylinus;
D O I
10.1002/bit.10618
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
An in-situ, mid-infrared sensor was used to monitor the major analyte concentrations involved in the cultivation of Gluconacetobacter xylinus and the production of gluconacetan, a food-grade exopolysaccharide. To predict the analyte concentrations, three different sets of standard spectra were used to develop calibration models, applying partial least-squares regression. It was possible to build a valid calibration model to predict the 700 spectra collected during the complete time course of the cultivation, using only 12 spectra collected every 10 h as standards. This model was used to reprocess the concentration profiles from 0 to 15 g/L of nine different analytes with a mean standard error of validation of 0.23 g/L. However, this calibration model was not suitable for real-time monitoring as it was probably based on nonspecific spectral features, which were correlated only with the measured analyte concentrations. Valid calibration models capable of real-time monitoring could be established by supplementing the set of 12 fermentation spectra with 42 standards of measured analytes. A pulse of 5 g/L ethanol showed the robustness of the model to sudden disturbances. The prediction of the models drifted, however, toward the end of the fermentation. The most robust calibration model was finally obtained by the addition of 34 standard spectra of non-measured analytes. Although the spectra did not contain analyte-specific information, it was believed that this addition would increase the variability space of the calibration model. Therefore, an expanded calibration model containing 88 spectra was used to monitor, in real time, the concentration profiles of fructose, acetic acid, ethanol and gluconacetan and allowed standard errors of prediction of 1.11, 0.37, 0.22, and 0.79 g/L, respectively. (C) 2003 Wiley Periodicals, Inc.
引用
收藏
页码:702 / 709
页数:8
相关论文
共 50 条
  • [1] Evaluation of a newly developed mid-infrared sensor for real-time monitoring of yeast fermentations
    Schalk, Robert
    Geoerg, Daniel
    Staubach, Jens
    Raedle, Matthias
    Methner, Frank-Juergen
    Beuermann, Thomas
    JOURNAL OF BIOSCIENCE AND BIOENGINEERING, 2017, 123 (05) : 651 - 657
  • [2] Real-time bioprocess monitoring using a mid-infrared fibre-optic sensor
    Alimagham, Farah
    Winterburn, James
    Dolman, Ben
    Domingues, Patrícia Maia
    Everest, Francesca
    Platkov, Max
    Basov, Svetlana
    Izakson, Gregory
    Katzir, Abraham
    Elliott, Stephen R.
    Hutter, Tanya
    Biochemical Engineering Journal, 2021, 167
  • [3] Real-time bioprocess monitoring using a mid-infrared fibre-optic sensor
    Alimagham, Farah
    Winterburn, James
    Dolman, Ben
    Domingues, Patricia Maia
    Everest, Francesca
    Platkov, Max
    Basov, Svetlana
    Izakson, Gregory
    Katzir, Abraham
    Elliott, Stephen R.
    Hutter, Tanya
    BIOCHEMICAL ENGINEERING JOURNAL, 2021, 167
  • [4] Real-time monitoring of the stable free radical polymerization of styrene via in-situ mid-infrared spectroscopy
    Pasquale, AJ
    Long, TE
    MACROMOLECULES, 1999, 32 (23) : 7954 - 7957
  • [5] Towards Real-Time In-Situ Mid-Infrared Spectroscopic Ellipsometry in Polymer Processing
    Ebner, Alexander
    Zimmerleiter, Robert
    Hingerl, Kurt
    Brandstetter, Markus
    POLYMERS, 2022, 14 (01)
  • [6] Real-time analyte monitoring of a fungal fermentation, at pilot scale, using in situ mid-infrared spectroscopy
    Pollard D.J.
    Buccino R.
    Connors N.C.
    Kirschner T.F.
    Olewinski R.C.
    Saini K.
    Salmon P.M.
    Bioprocess and Biosystems Engineering, 2001, 24 (1) : 13 - 24
  • [7] Real-time analyte monitoring of a fungal fermentation, at pilot scale, using in situ mid-infrared spectroscopy
    Pollard, DJ
    Buccino, R
    Connors, NC
    Kirschner, TF
    Olewinski, RC
    Saini, K
    Salmon, PM
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2001, 24 (01) : 13 - 24
  • [8] Real-time monitoring of nitrile biotransformations by mid-infrared spectroscopy
    Dadd, MR
    Sharp, DCA
    Pettman, AJ
    Knowles, CJ
    JOURNAL OF MICROBIOLOGICAL METHODS, 2000, 41 (01) : 69 - 75
  • [9] Real-Time Monitoring of Bioethanol Fermentation with Industrial Musts Using Mid-Infrared Spectroscopy
    Rodrigues, Kaio C. S.
    Sonego, Jorge L. S.
    Bernardo, Andre
    Ribeiro, Marcelo P. A.
    Cruz, Antonio J. G.
    Badino, Alberto C.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2018, 57 (32) : 10823 - 10831
  • [10] Real-time gas analysis using mid-infrared microcavities
    Jin, Tiening
    Zhou, Junchao
    Lin, Pao Tai
    CHEMICAL, BIOLOGICAL, RADIOLOGICAL, NUCLEAR, AND EXPLOSIVES (CBRNE) SENSING XIX, 2018, 10629