Monitoring of hydrogen sulfide via substrate-integrated hollow waveguide mid-infrared sensors in real-time

被引:74
|
作者
da Silveira Petruci, Joao Flavio [1 ,2 ]
Fortes, Paula Regina [2 ,3 ]
Kokoric, Vjekoslav [2 ]
Wilk, Andreas [2 ]
Raimundo, Ivo Milton, Jr. [3 ]
Cardoso, Arnaldo Alves [1 ]
Mizaikoff, Boris [2 ]
机构
[1] Sao Paulo State Univ, Dept Analyt Chem, UNESP, BR-14800970 Araraquara, SP, Brazil
[2] Univ Ulm, Inst Analyt & Bioanalyt Chem, D-89081 Ulm, Germany
[3] Univ Estadual Campinas, Dept Analyt Chem, UNICAMP, Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
GAS; SYSTEM;
D O I
10.1039/c3an01793a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hydrogen sulfide is a highly corrosive, harmful, and toxic gas produced under anaerobic conditions within industrial processes or in natural environments, and plays an important role in the sulfur cycle. According to the U.S. Occupational Safety and Health Administration (OSHA), the permissible exposure limit (during 8 hours) is 10 ppm. Concentrations of 20 ppm are the threshold for critical health issues. In workplace environments with human subjects frequently exposed to H2S, e. g., during petroleum extraction and refining, real-time monitoring of exposure levels is mandatory. Sensors based on electrochemical measurement principles, semiconducting metal-oxides, taking advantage of their optical properties, have been described for H2S monitoring. However, extended response times, limited selectivity, and bulkiness of the instrumentation are common disadvantages of the sensing techniques reported to date. Here, we describe for the first time usage of a new generation of compact gas cells, i.e., so-called substrate-integrated hollow waveguides (iHWGs), combined with a compact Fourier transform infrared (FTIR) spectrometer for advanced gas sensing of H2S. The principle of detection is based on the immediate UV-assisted conversion of the rather weak IR-absorber H2S into much more pronounced and distinctively responding SO2. A calibration was established in the range of 10-100 ppm with a limit of detection (LOD) at 3 ppm, which is suitable for occupational health monitoring purposes. The developed sensing scheme provides an analytical response time of less than 60 seconds. Considering the substantial potential for miniaturization using e. g., a dedicated quantum cascade laser (QCL) in lieu of the FTIR spectrometer, the developed sensing approach may be evolved into a hand-held instrument, which may be tailored to a variety of applications ranging from environmental monitoring to workplace safety surveillance, process analysis and clinical diagnostics, e. g., breath analysis.
引用
收藏
页码:198 / 203
页数:6
相关论文
共 50 条
  • [21] Evaluation of a newly developed mid-infrared sensor for real-time monitoring of yeast fermentations
    Schalk, Robert
    Geoerg, Daniel
    Staubach, Jens
    Raedle, Matthias
    Methner, Frank-Juergen
    Beuermann, Thomas
    JOURNAL OF BIOSCIENCE AND BIOENGINEERING, 2017, 123 (05) : 651 - 657
  • [22] Real-Time Monitoring of Bioethanol Fermentation with Industrial Musts Using Mid-Infrared Spectroscopy
    Rodrigues, Kaio C. S.
    Sonego, Jorge L. S.
    Bernardo, Andre
    Ribeiro, Marcelo P. A.
    Cruz, Antonio J. G.
    Badino, Alberto C.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2018, 57 (32) : 10823 - 10831
  • [23] Real-time bioprocess monitoring using a mid-infrared fibre-optic sensor
    Alimagham, Farah
    Winterburn, James
    Dolman, Ben
    Domingues, Patricia Maia
    Everest, Francesca
    Platkov, Max
    Basov, Svetlana
    Izakson, Gregory
    Katzir, Abraham
    Elliott, Stephen R.
    Hutter, Tanya
    BIOCHEMICAL ENGINEERING JOURNAL, 2021, 167
  • [24] Real-time measurement of CO2 isotopologue ratios in exhaled breath by a hollow waveguide based mid-infrared gas sensor
    Zhou, Tao
    Wu, Tao
    Wu, Qiang
    Ye, Chenwen
    Hu, Rongjing
    Chen, Weidong
    He, Xingdao
    OPTICS EXPRESS, 2020, 28 (08): : 10970 - 10980
  • [25] Infrared spectroscopy via substrate-integrated hollow waveguides: a powerful tool in catalysis research
    Kokoric, V.
    Widmann, D.
    Wittmann, M.
    Behm, R. J.
    Mizaikoff, B.
    ANALYST, 2016, 141 (21) : 5990 - 5995
  • [26] Online monitoring of carbon dioxide and oxygen in exhaled mouse breath via substrate-integrated hollow waveguide Fourier-transform infrared-luminescence spectroscopy
    Seichter, Felicia
    Tuetuencue, Erhan
    Hagemann, Leila Tamina
    Vogt, Josef
    Wachter, Ulrich
    Groeger, Michael
    Kress, Sandra
    Radermacher, Peter
    Mizaikoff, Boris
    JOURNAL OF BREATH RESEARCH, 2018, 12 (03)
  • [27] Real-time gas analysis using mid-infrared microcavities
    Jin, Tiening
    Zhou, Junchao
    Lin, Pao Tai
    CHEMICAL, BIOLOGICAL, RADIOLOGICAL, NUCLEAR, AND EXPLOSIVES (CBRNE) SENSING XIX, 2018, 10629
  • [28] Mid-infrared fiber sources for real-time biomedical sensing
    Woodward, R. I.
    Majewski, M. R.
    Bharathan, G.
    Hudson, D. D.
    Fuerbach, A.
    Jackson, S. D.
    OPTICAL BIOPSY XVII: TOWARD REAL-TIME SPECTROSCOPIC IMAGING AND DIAGNOSIS, 2019, 10873
  • [29] Innovative Substrate-Integrated Hollow Waveguide Coupled Attenuated Total Reflection Sensors for Quantum Cascade Laser Based Infrared Spectroscopy in Harsh Environments
    Teuber, Andrea
    Stach, Robert
    Haas, Julian
    Mizaikoff, Boris
    APPLIED SPECTROSCOPY, 2022, 76 (01) : 132 - 140
  • [30] Real-Time Monitoring of Ethanol Fermentation Using Mid-Infrared Spectroscopy Analysis of the Gas Phase
    Santos, Mayara, V
    Rodrigues, Kaio C. S.
    Veloso, Ivan I. K.
    Badino, Alberto C.
    Cruz, Antonio J. G.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2022, 61 (21) : 7225 - 7234