Real-time high-resolution mid-infrared optical coherence tomography

被引:195
|
作者
Israelsen, Niels M. [1 ,2 ]
Petersen, Christian R. [1 ,2 ]
Barh, Ajanta [1 ]
Jain, Deepak [1 ]
Jensen, Mikkel [1 ]
Hannesschlaeger, Guenther [3 ]
Tidemand-Lichtenberg, Peter [1 ,4 ]
Pedersen, Christian [1 ,4 ]
Podoleanu, Adrian [5 ]
Bang, Ole [1 ,2 ]
机构
[1] Tech Univ Denmark, DTU Foton, DK-2800 Lyngby, Denmark
[2] NORBLIS IVS, Virumgade 35 D, DK-2830 Virum, Denmark
[3] Res Ctr Nondestruct Testing RECENDT, Altenberger Str 69, A-4040 Linz, Austria
[4] NLIR ApS, Hirsemarken 1, DK-3520 Farum, Denmark
[5] Univ Kent, Sch Phys Sci, Appl Opt Grp, Canterbury CT2 7NH, Kent, England
关键词
HIGH-SPEED; MU-M; WAVELENGTH; INSPECTION; RANGE; DEPTH;
D O I
10.1038/s41377-019-0122-5
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The potential for improving the penetration depth of optical coherence tomography systems by using light sources with longer wavelengths has been known since the inception of the technique in the early 1990s. Nevertheless, the development of mid-infrared optical coherence tomography has long been challenged by the maturity and fidelity of optical components in this spectral region, resulting in slow acquisition, low sensitivity, and poor axial resolution. In this work, a mid-infrared spectral-domain optical coherence tomography system operating at a central wavelength of 4 mu m and an axial resolution of 8.6 mu m is demonstrated. The system produces two-dimensional cross-sectional images in real time enabled by a high-brightness 0.9- to 4.7-mu m mid-infrared supercontinuum source with a pulse repetition rate of 1 MHz for illumination and broadband upconversion of more than 1-mu m bandwidth from 3.58-4.63 mu m to 820-865 nm, where a standard 800-nm spectrometer can be used for fast detection. The images produced by the mid-infrared system are compared with those delivered by a state-of-the-art ultra-high-resolution near-infrared optical coherence tomography system operating at 1.3 mu m, and the potential applications and samples suited for this technology are discussed. In doing so, the first practical mid-infrared optical coherence tomography system is demonstrated, with immediate applications in real-time non-destructive testing for the inspection of defects and thickness measurements in samples that exhibit strong scattering at shorter wavelengths.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Real-time high-resolution mid-infrared optical coherence tomography
    Niels M. Israelsen
    Christian R. Petersen
    Ajanta Barh
    Deepak Jain
    Mikkel Jensen
    Günther Hannesschläger
    Peter Tidemand-Lichtenberg
    Christian Pedersen
    Adrian Podoleanu
    Ole Bang
    [J]. Light: Science & Applications, 8
  • [2] High-resolution mid-infrared optical coherence tomography with kHz line rate
    Israelsen, Niels M.
    Rodrigo, Peter John
    Petersen, Christian R.
    Woyessa, Getinet
    Hansen, Rasmus E.
    Tidemand-Lichtenberg, Peter
    Pedersen, Christian
    Bang, Ole
    [J]. OPTICS LETTERS, 2021, 46 (18) : 4558 - 4561
  • [3] Mid-infrared optical coherence tomography
    Colley, Christopher S.
    Hebden, Jeremy C.
    Delpy, David T.
    Cambrey, Alison D.
    Brown, Robert A.
    Zibik, Evgeny A.
    Ng, Wing H.
    Wilson, Luke R.
    Cockburn, John W.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (12):
  • [4] Non-Destructive Testing and Imaging of Marine Coatings using High-Resolution Mid-Infrared Optical Coherence Tomography
    Petersen, C. R.
    Markos, C.
    Israelsen, N. M.
    Rodrigo, P. J.
    Woyessa, G.
    Tidemand-Lichtenberg, Peter
    Pedersen, C.
    Bang, O.
    [J]. 2021 CONFERENCE ON LASERS AND ELECTRO-OPTICS EUROPE & EUROPEAN QUANTUM ELECTRONICS CONFERENCE (CLEO/EUROPE-EQEC), 2021,
  • [5] Mid-infrared optical coherence tomography with MHz axial line rate for real-time non-destructive testing
    Yagi, Satoko
    Nakamura, Takuma
    Hashimoto, Kazuki
    Kawano, Shotaro
    Ideguchi, Takuro
    [J]. APL PHOTONICS, 2024, 9 (05)
  • [6] High-resolution mid-infrared morphology of Cygnus A
    Radomski, JT
    Piña, RK
    Packham, C
    Telesco, CM
    Tadhunter, CN
    [J]. ASTROPHYSICAL JOURNAL, 2002, 566 (02): : 675 - 681
  • [7] Mid-infrared high-resolution spectrograph for SPICA
    Kobayashi, Naoto
    Ikeda, Yuji
    Kawakita, Hideyo
    Enya, Keigo
    Nakagawa, Takao
    Kataza, Hirokazu
    Matsuhara, Hideo
    Hirahara, Yasuhiro
    Tokoro, Hitoshi
    [J]. SPACE TELESCOPES AND INSTRUMENTATION 2008: OPTICAL, INFRARED, AND MILLIMETER, PTS 1 AND 2, 2008, 7010
  • [8] High-resolution mid-infrared observations of AGN
    Radomski, J. T.
    Packham, C.
    Perlman, E.
    Roche, P.
    Pina, R. K.
    Telesco, C. M.
    Aitken, D.
    Alonso-Herrero, A.
    Biretta, J.
    De Buizer, J. M.
    Fisher, R. S.
    Robinson, A.
    Sparks, W.
    Tadhunter, C.
    [J]. SPITZER SPACE TELESCOPE: NEW VIEWS OF THE COSMOS, 2006, 357 : 263 - +
  • [9] High-resolution mid-infrared morphology of Cygnus A
    Radomski, JT
    Piña, RK
    Packham, C
    Telesco, CM
    Tadhunter, CN
    [J]. CENTRAL KILOPARSEC OF STARBURSTS AND AGN: THE LA PALMA CONNECTION, 2001, 249 : 325 - 328
  • [10] Real-time, high velocity-resolution color Doppler optical coherence tomography
    Westphal, V
    Yazdanfar, S
    Rollins, AM
    Izatt, JA
    [J]. OPTICS LETTERS, 2002, 27 (01) : 34 - 36