Average Glandular Dose (AGD) and Radiation Dose Optimization in Screen-Film and Digital X-ray Mammography

被引:2
|
作者
Suliman, Ibrahim I. [1 ,2 ]
Mohamed, Sawsan [3 ]
Mahadi, Alaa [3 ]
Bashier, Einas [3 ]
Farah, Atifa [3 ]
Hassan, Nada [3 ]
Ibrahem, Moez A. [2 ]
Ali, Mohammed Khalil Mohammed [2 ]
Ahmed, Nada A. [4 ]
Ma, Chang Ming Charlie
机构
[1] Imam Mohammad Ibn Saud Islamic Univ IMSIU, Deanship Sci Res, Riyadh 13318, Saudi Arabia
[2] Imam Mohammad Ibn Saud Islamic Univ IMSIU, Coll Sci, Dept Phys, Riyadh 13318, Saudi Arabia
[3] Sudan Atom Energy Commiss, Nucl & Radiat Safety Inst, POB 3001, Khartoum, Sudan
[4] Taibah Univ, Coll Sci, Dept Phys, Madinah 30001, Saudi Arabia
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 21期
关键词
X-ray mammography; radiation dose; incident air kerma; diagnostic reference levels (DRLs); compressed breast thickness (CBT); radiation protection; DIAGNOSTIC REFERENCE LEVELS; BREAST; PERFORMANCE;
D O I
10.3390/app132111901
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
We determined the average glandular dose (AGD) from the craniocaudally (CC) and mediolateral oblique (MLO) views of 496 breasts (247 women) at eight clinics in Sudan. The incident air kerma from the X-ray tube output values and the typical patient-specific breast exposure factors were measured. The AGD values were inferred from the measured incident air kerma and breast-specific dose-conversion coefficients. The AGD per CC and MLO projection and per woman ranged from 0.56 to 2.89 mGy (average: 1.36), 0.48 to 2.08 mGy (average: 1.19), and 2.08 to 9.94 mGy (average: 5.10). The proposed national diagnostic reference levels (mGy) for digital mammography are 1.8 and 1.6 mGy for CC and MLO projection, respectively. Establishing the proposed diagnostic reference levels is an essential step in ensuring patient protection from radiation and will help promote dose optimization for X-ray mammography at the national level and beyond. These results provide important baseline data that can be used to formulate national diagnostic reference levels.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Imaging performance of a low-dose screen-film mammography system
    Jafroudi, H
    Jennings, RJ
    Gagne, RM
    Artz, DS
    Vucich, JJ
    Freedman, M
    Mun, SK
    PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 : 358 - 363
  • [22] Exposure Parameters and Average Glandular Dose in a Digital Mammography System in Japan
    Nishide, Hiroko
    Ohta, Kouji
    Murata, Kaori
    Kodera, Yoshie
    Shimamoto, Kazuhiro
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (05) : 1030 - 1034
  • [23] Digital vs. film-screen mammography: Radiation dose and SNR
    Nickoloff, E
    Dutta, A
    Lu, Z
    Smith, S
    Rosenblatt, R
    MEDICAL PHYSICS, 2002, 29 (06) : 1307 - 1307
  • [24] Digital mammography screening: Average glandular dose and first performance parameters
    Weigel, S.
    Girnus, R.
    Czwoydzinski, J.
    Decker, T.
    Spital, S.
    Heindel, W.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2007, 179 (09): : 892 - 895
  • [25] Effect of filter on average glandular dose and image quality in digital mammography
    Songsaeng, C.
    Krisanachinda, A.
    Theerakul, K.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [26] BREAST RADIATION-DOSE IN FILM SCREEN MAMMOGRAPHY
    PRADO, KL
    RAKOWSKI, JT
    BARRAGAN, F
    VANEK, KN
    HEALTH PHYSICS, 1988, 55 (01): : 81 - 83
  • [27] Evaluation of average glandular dose (AGD) in screening and diagnostic digital mammography and digital breast tomosynthesis (DBT) towards establishing a reference dose range band (DRB): a developing country experience
    Jeyasugiththan, Jeyasingam
    Maheshika Bandara, B. G. U.
    Wickramarathna, S. h dm
    Thenuwara, Hashini
    Satharasinghe, Duminda
    Pallewatte, A. S.
    Hettiarachchi, Pandula
    JOURNAL OF RADIOLOGICAL PROTECTION, 2023, 43 (03)
  • [28] Effect of X-Ray Tube Voltage and Radiation Dose on Modulation Transfer Function in Digital Mammography
    Karaaslan, Melike Kaya
    Avci, Onur Muhammed
    Muzoglu, Nedim
    Gundogdu, Ozcan
    2022 MEDICAL TECHNOLOGIES CONGRESS (TIPTEKNO'22), 2022,
  • [29] Digital vs film-screen mammography: Radiation dose and low contrast visualization
    Nickoloff, EL
    Smith, SJ
    Rosenblatt, R
    Dutta, AK
    Lu, Z
    RADIOLOGY, 2001, 221 : 189 - 190
  • [30] Comparison of Anode/Filter Combinations in Digital Mammography with Respect to the Average Glandular Dose
    Uhlenbrock, D. F.
    Mertelmeier, T.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2009, 181 (03): : 249 - 254