Effect of X-Ray Tube Voltage and Radiation Dose on Modulation Transfer Function in Digital Mammography

被引:0
|
作者
Karaaslan, Melike Kaya [1 ]
Avci, Onur Muhammed [2 ]
Muzoglu, Nedim [2 ]
Gundogdu, Ozcan [1 ]
机构
[1] Kocaeli Univ, Inst Sci, Dept Biomed Engn, Kocaeli, Turkey
[2] Istanbul Univ, Inst Sci, Dept Biomed Engn, Istanbul, Turkey
关键词
digital mammography; modulation transfer function (MTF); radiation dose; X-ray tube voltage; MTF;
D O I
10.1109/TIPTEKNO56568.2022.9960162
中图分类号
Q813 [细胞工程];
学科分类号
摘要
The Modulation Transfer Function (MTF) is a physical metric that explains the relationship between spatial resolution and contrast in the frequency domain for image quality evaluation. This study investigates the effect of the X-ray tube voltage (kVp) and radiation dose on MTF measurement in digital mammography. The MTF was determined for four radiation dose levels at two different kVp values according to the IEC 62220-1-2 standard. In conclusion, there was no significant difference between the results, and the MTF was determined to be independent of kVp and radiation dose.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Effect of dose metrics and radiation risk models when optimizing CT x-ray tube voltage
    Huda, W.
    Ogden, K. M.
    Khorasani, M. R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (17): : 4719 - 4732
  • [2] The Effect of Magnification on the Image Quality and the Radiation Dose in X-ray Digital Mammography: a Monte Carlo Simulation Study
    Choi, Yu-Na
    Kim, Hee-Joung
    Park, Hye-Suk
    Lee, Chang-Lae
    Cho, Hyo-Min
    Lee, Seung-Wan
    Ryu, Hyun-Ju
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2010, 57 (03) : 494 - 500
  • [3] A cermet X-ray tube for mammography
    Valuev N.N.
    Kulikov N.A.
    Kochetkov M.D.
    Taubin M.L.
    Biomedical Engineering, 2005, 39 (5) : 251 - 254
  • [4] Effect of area x-ray beam equalization on image quality and dose in digital mammography
    Wong, J
    Xu, T
    Husain, A
    Le, H
    Molloi, S
    MEDICAL PHYSICS, 2004, 31 (06) : 1712 - 1712
  • [5] Effect of area x-ray beam equalization on image quality and dose in digital mammography
    Wong, J
    Xu, T
    Husain, A
    Le, H
    Molloi, S
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (16): : 3539 - 3557
  • [6] Average Glandular Dose (AGD) and Radiation Dose Optimization in Screen-Film and Digital X-ray Mammography
    Suliman, Ibrahim I.
    Mohamed, Sawsan
    Mahadi, Alaa
    Bashier, Einas
    Farah, Atifa
    Hassan, Nada
    Ibrahem, Moez A.
    Ali, Mohammed Khalil Mohammed
    Ahmed, Nada A.
    Ma, Chang Ming Charlie
    APPLIED SCIENCES-BASEL, 2023, 13 (21):
  • [7] Effect of varying X-ray tube voltage and additional filtration on image quality and patient dose in digital radiography system
    Aksit, E.
    Yalcin, A.
    Olgar, T.
    APPLIED RADIATION AND ISOTOPES, 2023, 199
  • [8] Reduction of scattered radiation dose by X-ray shielding during mammography
    Koo, Bon-Yeoul
    Lee, Kwang-Sung
    RADIATION PHYSICS AND CHEMISTRY, 2020, 177
  • [9] An Evaluation of Image Quality and Dose for a Hologic Selenia Digital Mammography System with a Tungsten Anode X-Ray Tube
    Schueler, B.
    Fetterly, K.
    MEDICAL PHYSICS, 2008, 35 (06) : 2672 - +
  • [10] X-RAY MAMMOGRAPHY WITH SYNCHROTRON RADIATION
    BURATTINI, E
    GAMBACCINI, M
    MARZIANI, M
    RIMONDI, O
    INDOVINA, PL
    POCEK, M
    SIMONETTI, G
    BENASSI, M
    TIRELLI, C
    PASSARIELLO, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01): : 638 - 640