Effect of X-Ray Tube Voltage and Radiation Dose on Modulation Transfer Function in Digital Mammography

被引:0
|
作者
Karaaslan, Melike Kaya [1 ]
Avci, Onur Muhammed [2 ]
Muzoglu, Nedim [2 ]
Gundogdu, Ozcan [1 ]
机构
[1] Kocaeli Univ, Inst Sci, Dept Biomed Engn, Kocaeli, Turkey
[2] Istanbul Univ, Inst Sci, Dept Biomed Engn, Istanbul, Turkey
关键词
digital mammography; modulation transfer function (MTF); radiation dose; X-ray tube voltage; MTF;
D O I
10.1109/TIPTEKNO56568.2022.9960162
中图分类号
Q813 [细胞工程];
学科分类号
摘要
The Modulation Transfer Function (MTF) is a physical metric that explains the relationship between spatial resolution and contrast in the frequency domain for image quality evaluation. This study investigates the effect of the X-ray tube voltage (kVp) and radiation dose on MTF measurement in digital mammography. The MTF was determined for four radiation dose levels at two different kVp values according to the IEC 62220-1-2 standard. In conclusion, there was no significant difference between the results, and the MTF was determined to be independent of kVp and radiation dose.
引用
收藏
页数:3
相关论文
共 50 条
  • [31] DIGITAL MAMMOGRAPHY WITH USE OF X-RAY CAPILLARY OPTICS
    PEPPLER, WW
    KRUGER, DG
    ABREU, CC
    MACDONALD, CA
    KOCHARIAN, A
    HENDEE, E
    RADIOLOGY, 1995, 197 : 357 - 357
  • [32] A microfluoroscopic imaging system for digital x-ray mammography
    Nalcioglu, O
    Roeck, WW
    RADIOLOGY, 1997, 205 : 684 - 684
  • [33] A design of a low voltage x-ray tube
    Dershem, E
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA AND REVIEW OF SCIENTIFIC INSTRUMENTS, 1929, 18 (02): : 127 - 130
  • [34] Synchrotron radiation: New trend in X-ray mammography
    Burattini, E
    ACTA PHYSICA POLONICA A, 1997, 91 (04) : 707 - 713
  • [35] Radiation exposure in X-ray mammography -: A review.
    Säbel, M
    Aichinger, U
    Schulz-Wendtland, R
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (02): : 79 - 91
  • [36] VARIATION OF IMAGE QUALITY WITH X-RAY TUBE POTENTIAL IN MAMMOGRAPHY
    LAW, J
    FAULKNER, K
    SMITH, S
    BRITISH JOURNAL OF RADIOLOGY, 1989, 62 (734): : 192 - 192
  • [37] THE MEASUREMENT AND ROUTINE CHECKING OF MAMMOGRAPHY X-RAY TUBE KV
    LAW, J
    PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (08): : 1133 - 1139
  • [38] Modulation transfer function measurement of flash X-ray radiographic system
    Zhou, F.C.
    Guan, Y.H.
    Guangzi Xuebao/Acta Photonica Sinica, 2001, 30 (02):
  • [39] Wavefront transformation and the modulation transfer function of x-ray multilayer mirrors
    Artioukov, IA
    Fechtchenko, RM
    Vinogradov, AV
    JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2002, 4 (03): : 233 - 236
  • [40] MEASUREMENT OF MODULATION TRANSFER-FUNCTION OF X-RAY TOMOGRAPHIC SYSTEMS
    AMTEY, SR
    ISRAEL, JW
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (03): : 596 - 596