Effect of X-Ray Tube Voltage and Radiation Dose on Modulation Transfer Function in Digital Mammography

被引:0
|
作者
Karaaslan, Melike Kaya [1 ]
Avci, Onur Muhammed [2 ]
Muzoglu, Nedim [2 ]
Gundogdu, Ozcan [1 ]
机构
[1] Kocaeli Univ, Inst Sci, Dept Biomed Engn, Kocaeli, Turkey
[2] Istanbul Univ, Inst Sci, Dept Biomed Engn, Istanbul, Turkey
关键词
digital mammography; modulation transfer function (MTF); radiation dose; X-ray tube voltage; MTF;
D O I
10.1109/TIPTEKNO56568.2022.9960162
中图分类号
Q813 [细胞工程];
学科分类号
摘要
The Modulation Transfer Function (MTF) is a physical metric that explains the relationship between spatial resolution and contrast in the frequency domain for image quality evaluation. This study investigates the effect of the X-ray tube voltage (kVp) and radiation dose on MTF measurement in digital mammography. The MTF was determined for four radiation dose levels at two different kVp values according to the IEC 62220-1-2 standard. In conclusion, there was no significant difference between the results, and the MTF was determined to be independent of kVp and radiation dose.
引用
收藏
页数:3
相关论文
共 50 条
  • [41] Optimizing abdominal CT dose and image quality with respect to x-ray tube voltage
    Huda, W
    Ogden, KM
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 499 - 507
  • [42] MODULATION TRANSFER-FUNCTION OF A DIGITAL DENTAL-X-RAY SYSTEM
    CHEN, SK
    HOLLENDER, L
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1994, 77 (03): : 308 - 313
  • [43] A metal x-ray tube for characteristic radiation
    Ksanda, CJ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1932, 3 (10): : 531 - 534
  • [44] Radiation dose reduction with digital flat panel cardiac x-ray imaging
    Raman, SV
    Niklason, L
    Benali, K
    Bush, CA
    EUROPEAN HEART JOURNAL, 2002, 23 : 71 - 71
  • [45] Automatic transfer function generation for volume rendering of high resolution X-ray 3D digital mammography images
    Alyassin, AM
    MEDICAL IMAGING 2002: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2002, 4681 : 338 - 348
  • [46] Measurement of patient exposure dose on X-ray screening mammography
    Goto, S
    Azuma, Y
    Sumimoto, T
    Maruyama, T
    Eiho, S
    IMTC/2001: PROCEEDINGS OF THE 18TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3: REDISCOVERING MEASUREMENT IN THE AGE OF INFORMATICS, 2001, : 191 - 196
  • [47] Radiation dose and image quality in neuroangiography:: Effects of increased tube voltage, added X-ray filtration and antiscatter grid removal
    Söderman, M
    Hansson, B
    Axelsson, B
    INTERVENTIONAL NEURORADIOLOGY, 1998, 4 (03): : 199 - 207
  • [48] Influence of the crossover effect on X-ray tube voltage dependence of quantum mottle
    Arimura, H
    Okawa, T
    Ikari, T
    Okamoto, M
    Kubota, H
    Matsumoto, M
    Takigawa, A
    Nakamori, N
    Kanamori, H
    JOURNAL OF PHOTOGRAPHIC SCIENCE, 1996, 44 (06): : 178 - 186
  • [49] Ion transfer tube as the tube of optical to X-ray tubes
    Dolejsek, V.
    Kunzl, V.
    ZEITSCHRIFT FUR PHYSIK, 1932, 74 (7-8): : 565 - 573
  • [50] Monoenergetic X-ray beam in digital full field mammography
    Diekmann, F
    Diekmann, SD
    Fischer, T
    Arkadiev, V
    Lawaczeck, R
    Hamm, BK
    RADIOLOGY, 2002, 225 : 417 - 417