The influence of gravity on electrical impedance tomography measurements during upper body position change

被引:5
|
作者
Yang, Lin [1 ]
Gao, Zhijun [1 ]
Cao, Xinsheng [1 ]
Fu, Feng [2 ]
Moller, Knut [3 ]
Frerichs, Inez [4 ]
Dai, Meng [2 ]
Zhao, Zhanqi [3 ]
机构
[1] Fourth Mil Med Univ, Dept Aerosp Med, Xian, Peoples R China
[2] Fourth Mil Med Univ, Dept Biomed Engn, Xian, Peoples R China
[3] Furtwangen Univ, Inst Tech Med, Villingen Schwenningen, Germany
[4] Univ Med Ctr Schleswig Holstein, Dept Anaesthesiol & Intens Care Med, Campus Kiel, Kiel, Germany
基金
中国国家自然科学基金; 欧盟地平线“2020”;
关键词
Electrical impedance tomography; Ventilation distribution; Upper body position; Diaphragm; Gravity; VENTILATION;
D O I
10.1016/j.heliyon.2023.e15910
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective: The aim of the study was to examine the influence of gravity on regional ventilation measured by electrical impedance tomography (EIT) with the standard electrode belt position at the 5th intercostal space during tilting from supine to sitting positions. Methods: A total of 30 healthy volunteers were examined prospectively in supine position during quiet tidal breathing. Subsequently, the bed was tilted so that the upper body of the subjects achieved 30, 60 and 90 degrees every 3 min. Regional ventilation distribution and end-expiratory lung impedance (EELI) were monitored with EIT throughout the whole experiment. Absolute tidal volumes were measured with spirometry and the volume-impedance ratio was calculated for each position. Results: The volume-impedance ratio did not differ statistically between the studied body positions but 11 subjects exhibited a large change in ratio at one of the positions (outside 99.3% coverage). In general, ventilation distribution became more heterogeneous and moved towards dorsal regions as the upper body was tilted to 90-degree position. EELI increased and tidal volume decreased. The lung regions identified at various positions differed significantly. Conclusion: Gravity has non-negligible influence on EIT data, as the upper body tilted from supine to sitting positions. The standard electrode belt position might be reconsidered if ventilation distribution is to be compared between supine and sitting positions.
引用
收藏
页数:7
相关论文
共 50 条
  • [11] Body and head position effects on regional lung ventilation in infants: an electrical impedance tomography study
    Heinrich, Sina
    Schiffmann, Holger
    Frerichs, Alexander
    Klockgether-Radke, Adelbert
    Frerichs, Inez
    INTENSIVE CARE MEDICINE, 2006, 32 (09) : 1392 - 1398
  • [12] Body and head position effects on regional lung ventilation in infants: an electrical impedance tomography study
    Sina Heinrich
    Holger Schiffmann
    Alexander Frerichs
    Adelbert Klockgether-Radke
    Inéz Frerichs
    Intensive Care Medicine, 2006, 32
  • [13] The significance of electrical impedance measurements on the human body
    Horton, JW
    Hertz, S
    ENDOCRINOLOGY, 1936, 20 (06) : 831 - 838
  • [14] The influence of reference electrode in electrical impedance tomography
    Lin, Zhimin
    Huang, Weixiang
    Gao, Zhijun
    Yang, Lin
    Li, Yimin
    Lu, Yu
    Dai, Meng
    Fu, Feng
    Sang, Ling
    Zhao, Zhanqi
    HELIYON, 2022, 8 (12)
  • [15] An electrical impedance tomography system for current pulse measurements
    Kovacic, D
    Santic, A
    MEDICON 2001: PROCEEDINGS OF THE INTERNATIONAL FEDERATION FOR MEDICAL & BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2001, : 255 - 257
  • [16] BODY IMPEDANCE MEASUREMENTS DURING DIALYSIS
    DELORENZO, A
    BARRA, PFA
    SASSO, GF
    BATTISTINI, NC
    DEURENBERG, P
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 1991, 45 (06) : 321 - 325
  • [17] Evaluation of the response to the prone position through electrical impedance tomography
    Appendino, Gabriel
    Silveira, Juan Martin Nunez
    Lovesio, Carlos
    MEDICINA INTENSIVA, 2024, 48 (08) : 495 - 496
  • [18] Electrical impedance tomography signals in the lung are highly position dependent
    Graf, Michael
    Riedel, Thomas
    EUROPEAN RESPIRATORY JOURNAL, 2014, 44
  • [19] Ultrasound detection of diaphragm position in the region for lung monitoring by electrical impedance tomography during laparoscopy
    Buzkova, Kristyna
    Muller, Martin
    Rara, Ales
    Roubik, Karel
    Tyll, Tomas
    BIOMEDICAL PAPERS-OLOMOUC, 2018, 162 (01): : 43 - 46
  • [20] Applications for Electrical Impedance Tomography (EIT) and Electrical Properties of the Human Body
    Lymperopoulos, Georgios
    Lymperopoulos, Panagiotis
    Alikari, Victoria
    Dafogianni, Chrisoula
    Zyga, Sofia
    Margari, Nikoletta
    GENEDIS 2016: GERIATRICS, 2017, 989 : 109 - 117