The influence of gravity on electrical impedance tomography measurements during upper body position change

被引:5
|
作者
Yang, Lin [1 ]
Gao, Zhijun [1 ]
Cao, Xinsheng [1 ]
Fu, Feng [2 ]
Moller, Knut [3 ]
Frerichs, Inez [4 ]
Dai, Meng [2 ]
Zhao, Zhanqi [3 ]
机构
[1] Fourth Mil Med Univ, Dept Aerosp Med, Xian, Peoples R China
[2] Fourth Mil Med Univ, Dept Biomed Engn, Xian, Peoples R China
[3] Furtwangen Univ, Inst Tech Med, Villingen Schwenningen, Germany
[4] Univ Med Ctr Schleswig Holstein, Dept Anaesthesiol & Intens Care Med, Campus Kiel, Kiel, Germany
基金
中国国家自然科学基金; 欧盟地平线“2020”;
关键词
Electrical impedance tomography; Ventilation distribution; Upper body position; Diaphragm; Gravity; VENTILATION;
D O I
10.1016/j.heliyon.2023.e15910
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective: The aim of the study was to examine the influence of gravity on regional ventilation measured by electrical impedance tomography (EIT) with the standard electrode belt position at the 5th intercostal space during tilting from supine to sitting positions. Methods: A total of 30 healthy volunteers were examined prospectively in supine position during quiet tidal breathing. Subsequently, the bed was tilted so that the upper body of the subjects achieved 30, 60 and 90 degrees every 3 min. Regional ventilation distribution and end-expiratory lung impedance (EELI) were monitored with EIT throughout the whole experiment. Absolute tidal volumes were measured with spirometry and the volume-impedance ratio was calculated for each position. Results: The volume-impedance ratio did not differ statistically between the studied body positions but 11 subjects exhibited a large change in ratio at one of the positions (outside 99.3% coverage). In general, ventilation distribution became more heterogeneous and moved towards dorsal regions as the upper body was tilted to 90-degree position. EELI increased and tidal volume decreased. The lung regions identified at various positions differed significantly. Conclusion: Gravity has non-negligible influence on EIT data, as the upper body tilted from supine to sitting positions. The standard electrode belt position might be reconsidered if ventilation distribution is to be compared between supine and sitting positions.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Soil water infiltration measurements using electrical impedance tomography
    Gutierrez Gnecchi, J. A.
    Gomez-Tagle Chavez, A.
    Chavez Campos, G. M.
    Olivares Peregrino, V. H.
    Marroquin Pineda, E.
    CHEMICAL ENGINEERING JOURNAL, 2012, 191 : 13 - 21
  • [32] Statistical estimation of resistance/conductance by electrical impedance tomography measurements
    Demidenko, E
    Hartov, A
    Paulsen, K
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (07) : 829 - 838
  • [33] Electrical impedance tomography of the eye: In vitro measurements of the cornea and the lens
    Jurgens, I
    Rosell, J
    Riu, PJ
    PHYSIOLOGICAL MEASUREMENT, 1996, 17 : A187 - A195
  • [34] Measurement of body fat distribution by using electrical impedance tomography
    Ito, Tadashi
    Yamada, Shingo
    Kazama, Hideaki
    2006 SICE-ICASE INTERNATIONAL JOINT CONFERENCE, VOLS 1-13, 2006, : 194 - +
  • [35] Position-dependent distribution of ventilation measured with electrical impedance tomography
    Karagiannidis, Christian
    Waldmann, Andreas D.
    Ortola, Carlos Ferrando
    Munoz Martinez, Manuel
    Vidal, Anxela
    Santos, Arnoldo
    Roka, Peter L.
    Perez Marquez, Manuel
    Bohm, Stephan H.
    Suarez-Spimann, Fernando
    EUROPEAN RESPIRATORY JOURNAL, 2015, 46
  • [36] Modeling the influence of body position in bioimpedance measurements
    Medrano, G.
    Leonhardt, S.
    Zhang, P.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 3934 - 3937
  • [37] IMAGING OF ELECTRODE MOVEMENT AND CONDUCTIVITY CHANGE IN ELECTRICAL IMPEDANCE TOMOGRAPHY
    Quan, Wan
    Dinh, Anh
    2006 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-5, 2006, : 1033 - +
  • [38] Imaging of electrode movement and conductivity change in Electrical Impedance Tomography
    Gomez-Laberge, Camille
    Adler, Andy
    2006 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-5, 2006, : 1029 - +
  • [39] CHANGE IN THE UPPER EYELID POSITION DURING DOWNGAZE
    STOLLER, SH
    MEYER, DR
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 1121 - 1121
  • [40] Quantitative analysis of shape change in Electrical Impedance Tomography (EIT)
    Oh, Sungho
    Tang, Te
    Sadleir, Rosalind
    13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 424 - 427