The influence of gravity on electrical impedance tomography measurements during upper body position change

被引:5
|
作者
Yang, Lin [1 ]
Gao, Zhijun [1 ]
Cao, Xinsheng [1 ]
Fu, Feng [2 ]
Moller, Knut [3 ]
Frerichs, Inez [4 ]
Dai, Meng [2 ]
Zhao, Zhanqi [3 ]
机构
[1] Fourth Mil Med Univ, Dept Aerosp Med, Xian, Peoples R China
[2] Fourth Mil Med Univ, Dept Biomed Engn, Xian, Peoples R China
[3] Furtwangen Univ, Inst Tech Med, Villingen Schwenningen, Germany
[4] Univ Med Ctr Schleswig Holstein, Dept Anaesthesiol & Intens Care Med, Campus Kiel, Kiel, Germany
基金
中国国家自然科学基金; 欧盟地平线“2020”;
关键词
Electrical impedance tomography; Ventilation distribution; Upper body position; Diaphragm; Gravity; VENTILATION;
D O I
10.1016/j.heliyon.2023.e15910
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective: The aim of the study was to examine the influence of gravity on regional ventilation measured by electrical impedance tomography (EIT) with the standard electrode belt position at the 5th intercostal space during tilting from supine to sitting positions. Methods: A total of 30 healthy volunteers were examined prospectively in supine position during quiet tidal breathing. Subsequently, the bed was tilted so that the upper body of the subjects achieved 30, 60 and 90 degrees every 3 min. Regional ventilation distribution and end-expiratory lung impedance (EELI) were monitored with EIT throughout the whole experiment. Absolute tidal volumes were measured with spirometry and the volume-impedance ratio was calculated for each position. Results: The volume-impedance ratio did not differ statistically between the studied body positions but 11 subjects exhibited a large change in ratio at one of the positions (outside 99.3% coverage). In general, ventilation distribution became more heterogeneous and moved towards dorsal regions as the upper body was tilted to 90-degree position. EELI increased and tidal volume decreased. The lung regions identified at various positions differed significantly. Conclusion: Gravity has non-negligible influence on EIT data, as the upper body tilted from supine to sitting positions. The standard electrode belt position might be reconsidered if ventilation distribution is to be compared between supine and sitting positions.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Monitoring intraoperative tidal volume distribution using electrical impedance tomography during upper abdominal surgery
    Schaefer, M. S.
    Bastin, B.
    Schmalz, U.
    Wania, V.
    Treschan, T. A.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (01) : 99 - 99
  • [42] Electrical impedance tomography: Amplitudes of cardiac related impedance changes in the lung are highly position dependent
    Graf, Michael
    Riedel, Thomas
    PLOS ONE, 2017, 12 (11):
  • [43] DETERMINATION OF BODY-FLUID COMPARTMENTS BY ELECTRICAL IMPEDANCE MEASUREMENTS
    JENIN, P
    LENOIR, J
    ROULLET, C
    THOMASSET, AL
    DUCROT, H
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 1975, 46 (02): : 152 - 155
  • [44] Locating Impedance Change in Electrical Impedance Tomography Based on Multilevel BP Neural Network
    彭源
    莫玉龙
    Journal of Shanghai University, 2003, (03) : 251 - 255
  • [45] Investigation of potential artefactual changes in measurements of impedance changes during evoked activity: implications to electrical impedance tomography of brain function
    Aristovich, Kirill Y.
    Dos Santos, Gustavo S.
    Holder, David S.
    PHYSIOLOGICAL MEASUREMENT, 2015, 36 (06) : 1245 - 1259
  • [46] Gravity-dependent ventilation distribution in rats measured with electrical impedance tomography
    Rooney, Daniel
    Friese, Marlies
    Fraser, John F.
    Dunster, Kimble R.
    Schibler, Andreas
    PHYSIOLOGICAL MEASUREMENT, 2009, 30 (10) : 1075 - 1085
  • [47] Influence of the type and position of the sensor on the precision of impedance glucose measurements
    Olarte, Oscar
    Van Moer, Wendy
    Barbe, Kurt
    Van Ingelgem, Yves
    Rubin, Annick
    2013 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2013, : 1750 - 1754
  • [48] Cranial Electrode Belt Position Improves Diagnostic Possibilities of Electrical Impedance Tomography during Laparoscopic Surgery with Capnoperitoneum
    Koldova, Kristyna
    Rara, Ales
    Mueller, Martin
    Tyll, Tomas
    Roubik, Karel
    SENSORS, 2023, 23 (20)
  • [49] Perioperative assessment of regional ventilation during changing body positions and ventilation conditions by electrical impedance tomography
    Ukere, A.
    Maerz, A.
    Wodack, K. H.
    Trepte, C. J.
    Haese, A.
    Waldmann, A. D.
    Bohm, S. H.
    Reuter, D. A.
    BRITISH JOURNAL OF ANAESTHESIA, 2016, 117 (02) : 228 - 235
  • [50] Influence of Reconstruction Algorithms on Harmonic Analysis in Electrical Impedance Tomography
    Stein, Erik
    Chen, Rongqing
    Battistel, Alberto
    Lovas, Andras
    Benyo, Balazs
    Moeller, Knut
    IFAC PAPERSONLINE, 2023, 56 (02): : 5615 - 5619