BODY IMPEDANCE MEASUREMENTS DURING DIALYSIS

被引:0
|
作者
DELORENZO, A
BARRA, PFA
SASSO, GF
BATTISTINI, NC
DEURENBERG, P
机构
[1] UNIV LA SAPIENZA,MED CLINIC 6,I-00152 ROME,ITALY
[2] UNIV MODENA,DEPT HUMAN PHYSIOL,I-41100 MODENA,ITALY
[3] AGR UNIVERSITY WAGENINGEN,DEPT HUMAN NUTR,6703 HD WAGENINGEN,NETHERLANDS
关键词
D O I
暂无
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Changes in body weight in relation to changes in body impedance were studied in six male and four female patients before and during dialysis. Before dialysis, fat-free mass from skinfolds was 46.5 +/- 6.8 kg, and total body water calculated from bio-electrical impedance was 36.9 +/- 5.2 kg. Body water expressed as a percentage of fat-free mass was calculated to be 80 +/- 4%. Mean weight loss, which was assumed to be only loss of water, was 2.7 +/- 0.7 kg. Total body impedance increased by 80 +/- 16 OMEGA from 495 +/- 39 OMEGA to 575 +/- 47 OMEGA. Weight loss and increased in body impedance were highly correlated (r = -0.91, P < 0.001). However, based on prediction formulas for total body water from bio-electrical impedance, the observed weight (water) loss should be associated with an increase in impedance of only 39 +/- 11 OMEGA. It is concluded that the impedance value before dialysis is a relatively low value, due to the low specific resistivity of the excess of extra-cellular water in the body before dialysis. As a consequence, prediction formulas for body composition from bio-electrical impedance, developed in normal hydrated subjects, overestimate body composition (total body water, fat-free mass) in subjects with oedema.
引用
收藏
页码:321 / 325
页数:5
相关论文
共 50 条
  • [1] Comparison of segmental with whole-body impedance measurements in peritoneal dialysis patients
    Nescolarde, Lexa
    Donate, Teresa
    Piccoh, Antonio
    Rosell, Javier
    MEDICAL ENGINEERING & PHYSICS, 2008, 30 (07) : 817 - 824
  • [2] Continuous measurements by impedance of haematocrit and plasma volume variations during dialysis
    Maasrani, M.
    Jaffrin, M.Y.
    Boudailliez, B.
    Medical and Biological Engineering and Computing, 1997, 35 (03): : 167 - 171
  • [3] Continuous measurements by impedance of haematocrit and plasma volume variations during dialysis
    M. Maasrani
    M. Y. Jaffrin
    B. Boudailliez
    Medical and Biological Engineering and Computing, 1997, 35 : 167 - 171
  • [4] Continuous measurements by impedance of haematocrit and plasma volume variations during dialysis
    Maasrani, M
    Jaffrin, MY
    Boudailliez, B
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (03) : 167 - 171
  • [5] MULTIFREQUENCY IMPEDANCE IN THE ASSESSMENT OF BODY-WATER LOSSES DURING DIALYSIS
    DELORENZO, A
    DEURENBERG, P
    ANDREOLI, A
    SASSO, GF
    PALESTINI, M
    DOCIMO, R
    RENAL PHYSIOLOGY AND BIOCHEMISTRY, 1994, 17 (06): : 326 - 332
  • [6] Multifrequency impedance in the assessment of body water losses during dialysis - Comment
    Ward, LC
    Thomas, BJ
    Cornish, BH
    RENAL PHYSIOLOGY AND BIOCHEMISTRY, 1995, 18 (05): : 267 - 268
  • [7] Multifrequency impedance in the assessment of body water losses during dialysis - Reply
    DeLorenzo, A
    Deurenberg, P
    Andreoli, A
    Sasso, GF
    Palestini, M
    Docimo, R
    RENAL PHYSIOLOGY AND BIOCHEMISTRY, 1995, 18 (05): : 269 - 270
  • [8] Different impedance indexes in segmental and whole-body measurements in peritoneal dialysis patients
    Nescolarde, L.
    Donate, T.
    Garcia, M. A.
    Rosell-Ferrer, J.
    13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 779 - +
  • [9] Measurements of body impedance for ESD
    Wu, ZC
    Huang, JS
    Liu, SH
    ELECTRICAL OVERSTRESS/ELECTROSTATIC DISCHARGE SYMPOSIUM PROCEEDINGS 1997, 1997, : 132 - 134
  • [10] Measurements of body impedance for ESD
    Wu, ZC
    Lu, SG
    ISTM/97 - 2ND INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, CONFERENCE PROCEEDINGS, 1997, : 318 - 320