Continuous measurements by impedance of haematocrit and plasma volume variations during dialysis

被引:0
|
作者
M. Maasrani
M. Y. Jaffrin
B. Boudailliez
机构
[1] Technological University of Compiegne,URA CNRS 858
[2] Hopital Nord,Service de Pédiatrie
关键词
Blood impedance; Blood resistivity; Haematocrit and volemia monitoring; Haemodialysis;
D O I
暂无
中图分类号
学科分类号
摘要
A technique for continuous measurements of haematocrit and plasma volume in the arterial line of dialysed patients has been tested in vitro and in vivo. This method uses impedance measurements at 5 kHz and requires a single haematocrit measurement. It relies on two assumptions: that plasma resistivity does not change during dialysis and that blood resistivity obeys Hanai’s model. Both assumptions are verified during in vitro tests. Haematocrits measured in vivo by this method are found to be in good agreemnt with direct measurements from blood samples. The haematocrit variation is then used to monitor changes in plasma volume, assuming conservation of erythrocyte volume. In addition, it is possible to obtain the variation in interstitial volume by combining these data with body impedance measurements.
引用
收藏
页码:167 / 171
页数:4
相关论文
共 50 条
  • [1] Continuous measurements by impedance of haematocrit and plasma volume variations during dialysis
    Maasrani, M
    Jaffrin, MY
    Boudailliez, B
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (03) : 167 - 171
  • [2] Continuous measurements by impedance of haematocrit and plasma volume variations during dialysis
    Maasrani, M.
    Jaffrin, M.Y.
    Boudailliez, B.
    Medical and Biological Engineering and Computing, 1997, 35 (03): : 167 - 171
  • [3] Haematocrit and plasma volume during induction of anaesthesia
    Saito, Junichi
    Hirota, Kazuyoshi
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2018, 62 (09) : 1330 - 1331
  • [4] Reply to "Haematocrit and plasma volume during induction of anaesthesia"
    Damen, Tor
    Andreas Nygren
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2018, 62 (09) : 1332 - 1332
  • [5] BODY IMPEDANCE MEASUREMENTS DURING DIALYSIS
    DELORENZO, A
    BARRA, PFA
    SASSO, GF
    BATTISTINI, NC
    DEURENBERG, P
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 1991, 45 (06) : 321 - 325
  • [6] Haematocrit monitoring and blood volume estimation during continuous renal replacement therapy
    Baldwin, Ian
    Maeda, Akinori
    Bellomo, Rinaldo
    See, Emily
    AUSTRALIAN CRITICAL CARE, 2024, 37 (04) : 632 - 637
  • [7] Haematocrit, plasma volume and noradrenaline in humans during simulated weightlessness for 42 days
    Johansen, LB
    Gharib, C
    Allevard, AM
    Sigaudo, D
    Christensen, NJ
    Drummer, C
    Norsk, P
    CLINICAL PHYSIOLOGY, 1997, 17 (02): : 203 - 210
  • [8] Continuous haematocrit monitoring during intradialytic hypotension: precipitous decline in plasma refill rates
    Schroeder, KL
    Sallustio, JE
    Ross, EA
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2004, 19 (03) : 652 - 656
  • [9] Pressure-dependent changes in haematocrit and plasma volume during anaesthesia, a randomised clinical trial
    Damen, T.
    Reinsfelt, B.
    Redfors, B.
    Nygren, A.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2016, 60 (05) : 560 - 568
  • [10] EFFECT OF EXERCISE ON HAEMATOCRIT, PLASMA VOLUME AND VISCOSITY IN DIABETES MELLITUS
    LANGER, L
    BERGENTZ, SE
    BJURE, J
    FAGERBERG, SE
    DIABETOLOGIA, 1971, 7 (01) : 29 - +