Continuous measurements by impedance of haematocrit and plasma volume variations during dialysis

被引:0
|
作者
M. Maasrani
M. Y. Jaffrin
B. Boudailliez
机构
[1] Technological University of Compiegne,URA CNRS 858
[2] Hopital Nord,Service de Pédiatrie
来源
Medical and Biological Engineering and Computing | 1997年 / 35卷
关键词
Blood impedance; Blood resistivity; Haematocrit and volemia monitoring; Haemodialysis;
D O I
暂无
中图分类号
学科分类号
摘要
A technique for continuous measurements of haematocrit and plasma volume in the arterial line of dialysed patients has been tested in vitro and in vivo. This method uses impedance measurements at 5 kHz and requires a single haematocrit measurement. It relies on two assumptions: that plasma resistivity does not change during dialysis and that blood resistivity obeys Hanai’s model. Both assumptions are verified during in vitro tests. Haematocrits measured in vivo by this method are found to be in good agreemnt with direct measurements from blood samples. The haematocrit variation is then used to monitor changes in plasma volume, assuming conservation of erythrocyte volume. In addition, it is possible to obtain the variation in interstitial volume by combining these data with body impedance measurements.
引用
收藏
页码:167 / 171
页数:4
相关论文
共 50 条
  • [31] PLASMA VOLUME MEASUREMENTS IN CIRRHOSIS
    LIEBERMAN, FL
    REYNOLDS, TB
    GASTROENTEROLOGY, 1967, 52 (2P1) : 319 - +
  • [32] VARIATIONS OF PLASMA AND BLOOD-CELL VOLUME IN MICE DURING FRIENDS DISEASE
    GALLIENLARTIGUE, O
    HUAULME, D
    COMPTES RENDUS HEBDOMADAIRES DES SEANCES DE L ACADEMIE DES SCIENCES SERIE D, 1970, 270 (05): : 736 - +
  • [33] PLASMA REFILLING DURING DIALYSIS
    Ahmed, Alayoud
    Ahmed, Alayoud
    Amine, Hamzi
    Oualim, Zouhir
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2012, 27 : 203 - 203
  • [34] Development of an ion selective electrode for continuous monitoring of plasma potassium activity during dialysis
    Harriott, F
    Gratzl, M
    CANADIAN MEDICAL AND BIOLOGICAL ENGINEERING SOCIETY, PROCEEDINGS, 1997, : 102 - 103
  • [35] Continuous monitoring during dialysis - Introduction
    Lindsay, RM
    ADVANCES IN RENAL REPLACEMENT THERAPY, 1999, 6 (03): : 215 - 216
  • [36] Accuracy of ultrafiltration volume measurements for patients on peritoneal dialysis
    Mahon, A
    Fan, SLS
    PERITONEAL DIALYSIS INTERNATIONAL, 2005, 25 (01): : 92 - 93
  • [37] Averaging improves the quality of impedance stroke volume measurements during the head up tilt test
    Zhang Y.
    Critchley L.A.H.
    Critchley J.A.J.H.
    Journal of Clinical Monitoring and Computing, 2002, 17 (3-4) : 187 - 193
  • [38] WHOLE-BODY IMPEDANCE CHANGES ASSOCIATED WITH BODY-WATER VOLUME CHANGES DURING RENAL DIALYSIS
    RASMANN, DN
    HAMILTON, LH
    SPURR, GB
    FEDERATION PROCEEDINGS, 1984, 43 (03) : 719 - 719
  • [39] DETERMINATION OF EXTRACELLULAR FLUID VOLUME USING IMPEDANCE MEASUREMENTS
    ESPEJO, MGA
    NEU, J
    HAMILTON, L
    EITZMAN, B
    GIMOTTY, P
    BUCCIARELLI, RL
    CRITICAL CARE MEDICINE, 1989, 17 (04) : 360 - 363
  • [40] STROKE VOLUME IN THE DOG - MEASUREMENTS BY THE IMPEDANCE TECHNIQUE AND THERMODILUTION
    SPINELLI, JC
    VALENTINUZZI, ME
    MEDICAL PROGRESS THROUGH TECHNOLOGY, 1983, 10 (01) : 45 - 53