Continuous measurements by impedance of haematocrit and plasma volume variations during dialysis

被引:0
|
作者
M. Maasrani
M. Y. Jaffrin
B. Boudailliez
机构
[1] Technological University of Compiegne,URA CNRS 858
[2] Hopital Nord,Service de Pédiatrie
来源
Medical and Biological Engineering and Computing | 1997年 / 35卷
关键词
Blood impedance; Blood resistivity; Haematocrit and volemia monitoring; Haemodialysis;
D O I
暂无
中图分类号
学科分类号
摘要
A technique for continuous measurements of haematocrit and plasma volume in the arterial line of dialysed patients has been tested in vitro and in vivo. This method uses impedance measurements at 5 kHz and requires a single haematocrit measurement. It relies on two assumptions: that plasma resistivity does not change during dialysis and that blood resistivity obeys Hanai’s model. Both assumptions are verified during in vitro tests. Haematocrits measured in vivo by this method are found to be in good agreemnt with direct measurements from blood samples. The haematocrit variation is then used to monitor changes in plasma volume, assuming conservation of erythrocyte volume. In addition, it is possible to obtain the variation in interstitial volume by combining these data with body impedance measurements.
引用
收藏
页码:167 / 171
页数:4
相关论文
共 50 条
  • [21] Seasonal Variations of Impedance in the Ionospheric Plasma
    Unal, Ibrahim
    Karatay, Secil
    Yesil, Ali
    Hancerliogullari, Aybaba
    JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, 2020, 23 (02): : 427 - 433
  • [22] Meta-analysis: Effects of glycerol administration on plasma volume, haemoglobin, and haematocrit
    Koehler, Karsten
    Thevis, Mario
    Schaenzer, Wilhelm
    DRUG TESTING AND ANALYSIS, 2013, 5 (11-12) : 896 - 899
  • [23] CONTINUOUS MEASUREMENTS OF TISSUE IMPEDANCE DURING SECRETION IN DOG SUBMANDIBULAR-GLAND
    NAKAHARI, T
    MIYAMOTO, M
    YOSHIDA, H
    TANAKA, H
    IMAI, Y
    JAPANESE JOURNAL OF PHYSIOLOGY, 1988, 38 (05): : 699 - 712
  • [24] BLOOD FLOW MEASUREMENTS BY ELECTRICAL IMPEDANCE VARIATIONS
    SAINZ, A
    PINARDI, G
    ACTA CIENTIFICA VENEZOLANA, 1969, 20 (3-4): : 86 - &
  • [25] KINETIC MODELING AND CONTINUOUS ONLINE BLOOD-VOLUME MEASUREMENT DURING DIALYSIS THERAPY
    MANN, H
    STILLER, S
    GLADZIWA, U
    KONIGS, F
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 1990, 5 : 144 - 146
  • [26] PLASMA 18-HYDROXYCORTICOSTERONE DURING CONTINUOUS AMBULATORY PERITONEAL-DIALYSIS
    ZAGER, PG
    FREY, HJ
    GERDES, BG
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1983, 102 (04): : 604 - 612
  • [27] Reversibility of artifacts of fluid volume measurements by bioimpedance caused by position changes during dialysis
    Fenech, M
    Jaffrin, MY
    Malmen, U
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2002, 25 (03): : 217 - 222
  • [28] MULTIFREQUENCY IMPEDANCE MEASUREMENTS OF EXTRACELLULAR FLUID VOLUME
    WITHERS, P
    PHYSIOLOGICAL MEASUREMENT, 1995, 16 (01) : 71 - 73
  • [29] IMPEDANCE MEASUREMENTS OF A BOUNDED PLASMA IN RESONANCE
    LEE, QH
    ASMUSSEN, J
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1970, 15 (11): : 1469 - &
  • [30] Noninvasive Continuous Measurements of Stroke Volume Changes During Hemorrhage and Vasopressor Administration Using Portable Electrical Impedance Tomography (EIT): Animal Experiments
    Woo, E.
    Joo, H.
    Jang, G.
    Oh, T.
    Ko, R.
    Chung, C.
    Suh, G.
    Kim, Y.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2020, 201