BODY IMPEDANCE MEASUREMENTS DURING DIALYSIS

被引:0
|
作者
DELORENZO, A
BARRA, PFA
SASSO, GF
BATTISTINI, NC
DEURENBERG, P
机构
[1] UNIV LA SAPIENZA,MED CLINIC 6,I-00152 ROME,ITALY
[2] UNIV MODENA,DEPT HUMAN PHYSIOL,I-41100 MODENA,ITALY
[3] AGR UNIVERSITY WAGENINGEN,DEPT HUMAN NUTR,6703 HD WAGENINGEN,NETHERLANDS
关键词
D O I
暂无
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Changes in body weight in relation to changes in body impedance were studied in six male and four female patients before and during dialysis. Before dialysis, fat-free mass from skinfolds was 46.5 +/- 6.8 kg, and total body water calculated from bio-electrical impedance was 36.9 +/- 5.2 kg. Body water expressed as a percentage of fat-free mass was calculated to be 80 +/- 4%. Mean weight loss, which was assumed to be only loss of water, was 2.7 +/- 0.7 kg. Total body impedance increased by 80 +/- 16 OMEGA from 495 +/- 39 OMEGA to 575 +/- 47 OMEGA. Weight loss and increased in body impedance were highly correlated (r = -0.91, P < 0.001). However, based on prediction formulas for total body water from bio-electrical impedance, the observed weight (water) loss should be associated with an increase in impedance of only 39 +/- 11 OMEGA. It is concluded that the impedance value before dialysis is a relatively low value, due to the low specific resistivity of the excess of extra-cellular water in the body before dialysis. As a consequence, prediction formulas for body composition from bio-electrical impedance, developed in normal hydrated subjects, overestimate body composition (total body water, fat-free mass) in subjects with oedema.
引用
收藏
页码:321 / 325
页数:5
相关论文
共 50 条
  • [41] CHANGES IN BODY COMPOSITION USING BIOELECTRICAL IMPEDANCE IN PATIENTS ON PERITONEAL DIALYSIS (PD) PREVALENT
    Cristina DI Gioia, Maria
    Gallar, Paloma
    Laso, Nuria
    Rodriguez, Isabel
    Cobo, Gabriela
    Oliet, Aniana
    Hynostroza, Julie
    Carlos Herrero, Juan
    Mon, Carmen
    Ortiz, Milagros
    Vigil, Ana
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2012, 27 : 465 - 466
  • [42] HOW VALID ARE BIOELECTRIC IMPEDANCE MEASUREMENTS IN BODY-COMPOSITION STUDIES
    SOLOMONS, NW
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1986, 44 (02): : 306 - 307
  • [43] HOW VALID ARE BIOELECTRIC IMPEDANCE MEASUREMENTS IN BODY-COMPOSITION STUDIES
    COHN, SH
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1985, 42 (05): : 889 - 890
  • [44] Measurement of body fluid volume change using multisite impedance measurements
    Patterson, R.
    Ranganathan, C.
    Engel, R.
    Berkseth, R.
    Medical and Biological Engineering and Computing, 1988, 26 (01): : 33 - 37
  • [45] BODY-COMPOSITION ASSESSMENT OF ATHLETES USING BIOELECTRICAL IMPEDANCE MEASUREMENTS
    LUKASKI, HC
    BOLONCHUK, WW
    SIDERS, WA
    HALL, CB
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 1990, 30 (04): : 434 - 440
  • [46] The influence of body position on bioelectrical impedance spectroscopy measurements in young children
    Jaz Lyons-Reid
    Leigh C. Ward
    Mya-Thway Tint
    Timothy Kenealy
    Keith M. Godfrey
    Shiao-Yng Chan
    Wayne S. Cutfield
    Scientific Reports, 11
  • [47] The influence of body position on bioelectrical impedance spectroscopy measurements in young children
    Lyons-Reid, Jaz
    Ward, Leigh C.
    Tint, Mya-Thway
    Kenealy, Timothy
    Godfrey, Keith M.
    Chan, Shiao-Yng
    Cutfield, Wayne S.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [48] INFLUENCE OF AMBIENT TEMPERATURE ON CENTRAL AND PERIPHERAL IMPEDANCE MEASUREMENTS OF THE HUMAN BODY
    Corciova, Calin
    Ciorap, Radu
    Zaharia, Dan
    Salceanu, Alexandru
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2011, 10 (04): : 511 - 517
  • [49] DIALYSANCE AND CLEARANCE MEASUREMENTS DURING CLINICAL DIALYSIS - PLEA FOR STANDARDIZATION
    BASS, OE
    NOLPH, KD
    MAHER, JF
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1975, 86 (03): : 378 - 385
  • [50] Influence of ionic shifts during dialysis on volume estimations with multifrequency impedance analysis
    Scharfetter, H
    Wirnsberger, GH
    Holzer, H
    Hutten, H
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (02) : 96 - 102