Applications for Electrical Impedance Tomography (EIT) and Electrical Properties of the Human Body

被引:10
|
作者
Lymperopoulos, Georgios [1 ]
Lymperopoulos, Panagiotis [2 ]
Alikari, Victoria [3 ]
Dafogianni, Chrisoula [4 ]
Zyga, Sofia [5 ]
Margari, Nikoletta [4 ]
机构
[1] Univ Southern Calif, Dept Elect Engn, Sch Engn, Los Angeles, CA 90007 USA
[2] Univ Patras, Sch Engn, Dept Mech & Aeronaut Engn, Patras, Greece
[3] Univ Peloponnese, Fac Human Movement & Qual Life Sci, Dept Nursing, Lab Nursing Res & Practice, Tripoli, Libya
[4] Technol Educ Inst Athens, Dept Nursing, Athens, Greece
[5] Univ Peloponnese, Fac Human Movement & Qual Life Sci, Dept Nursing, Tripoli, Greece
来源
GENEDIS 2016: GERIATRICS | 2017年 / 989卷
关键词
Electrical impedance tomography; Skin resistance; Medical applications; Conductivity; Tumor; RECONSTRUCTION; LUNG;
D O I
10.1007/978-3-319-57348-9_9
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Electrical Impedance Tomography (EIT) is a promising application that displays changes in conductivity within a body. The basic principle of the method is the repeated measurement of surface voltages of a body, which are a result of rolling injection of known and small-volume sinusoidal AC current to the body through the electrodes attached to its surface. This method finds application in biomedicine, biology and geology. The objective of this paper is to present the applications of Electrical Impedance Tomography, along with the method's capabilities and limitations due to the electrical properties of the human body. For this purpose, investigation of existing literature has been conducted, using electronic databases, PubMed, Google Scholar and IEEE Xplore. In addition, there was a secondary research phase, using paper citations found during the first research phase. It should be noted that Electrical Impedance Tomography finds use in a plethora of medical applications, as the different tissues of the body have different conductivities and dielectric constants. Main applications of EIT include imaging of lung function, diagnosis of pulmonary embolism, detection of tumors in the chest area and diagnosis and distinction of ischemic and hemorrhagic stroke. EIT advantages include portability, low cost and safety, which the method provide, since it is a noninvasive imaging method that does not cause damage to the body. The main disadvantage of the method, which blocks its wider spread, appears in the image composition from the voltage measurements, which are conducted by electrodes placed on the periphery of the body, because the injected currents are affected nonlinearly by the general distribution of the electrical properties of the body. Furthermore, the complex impedance of the skin-electrode interface can be modelled by using a capacitor and two resistor, as a result of skin properties. In conclusion, Electrical Impedance Tomography is a promising method for the development of noninvasive diagnostic medicine, since it is able to provide imaging of the interior of the human body in real time without causing harm or putting the human body in risk.
引用
收藏
页码:109 / 117
页数:9
相关论文
共 50 条
  • [1] Applications of Electrical Impedance Tomography (EIT): A Short Review
    Bera, Tushar Kanti
    [J]. 3RD INTERNATIONAL CONFERENCE ON COMMUNICATION SYSTEMS (ICCS-2017), 2018, 331
  • [2] The electrical properties of real head model based on electrical impedance tomography (EIT)
    Xu, GZ
    Yang, QX
    Li, Y
    Wu, Q
    Yan, WL
    [J]. PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 994 - 997
  • [3] Electrical impedance tomography (EIT) in pulmonary measurement: A review of applications and research
    Panoutsos, George
    Mahfouf, Mahdi
    Brown, Brian H.
    Mills, Gary H.
    [J]. PROCEEDINGS OF THE FIFTH IASTED INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, 2007, : 221 - 230
  • [5] Extraction of Core Data in Electrical Impedance Tomography (EIT)
    Zhang, Hanyu
    Li, Nan
    [J]. 2023 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, I2MTC, 2023,
  • [6] Three methods for the inverse problem of electrical impedance tomography (EIT)
    Rao, LY
    He, RJ
    Yan, WL
    Bai, J
    [J]. APPLIED ELECTROMAGNETICS (II), 1998, 7 : 78 - 82
  • [7] DESIGN AND IMPLEMENTATION OF PRECISE HARDWARE FOR ELECTRICAL IMPEDANCE TOMOGRAPHY (EIT)
    Khalighi, M.
    Vahdat, B. Vosoughi
    Mortazavi, M.
    Mikaeili, M.
    [J]. IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF ELECTRICAL ENGINEERING, 2014, 38 (E1) : 1 - 20
  • [8] Quantitative analysis of shape change in Electrical Impedance Tomography (EIT)
    Oh, Sungho
    Tang, Te
    Sadleir, Rosalind
    [J]. 13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 424 - 427
  • [9] Gold Electrode Sensors for Electrical Impedance Tomography (EIT) Studies
    Bera, Tushar Kanti
    Nagaraju, J.
    [J]. 2011 IEEE SENSORS APPLICATIONS SYMPOSIUM (SAS), 2011, : 24 - 28
  • [10] Design, construction and evaluation of a system in electrical impedance tomography (EIT).: Applications on cerebral tissue in rats
    Andrés, G
    Aguillón, MA
    Rafael, S
    Erika, L
    Angel, Z
    [J]. SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 1760 - 1761