Development of a Composite Cu(II)-Selective Potentiometric Sensor Based on a Thiourea Derivative Symmetric Schiff Base

被引:2
|
作者
Yildirim, Ozden [1 ]
Coldur, Fatih [2 ]
Topcu, Cihan [3 ]
Caglar, Bulent [2 ]
机构
[1] Erzincan Binali Yildirim Univ, Grad Sch Nat & Appl Sci, TR-24100 Erzincan, Turkiye
[2] Erzincan Binali Yildirim Univ, Fac Arts & Sci, Dept Chem, TR-24100 Erzincan, Turkiye
[3] Samsun Univ, Fac Engn, Dept Biomed Engn, TR-55420 Samsun, Turkiye
关键词
Potentiometric sensor; copper(II)-selective electrode; all-solid-state sensor; copper(II) determination; Schiff base; thiourea derivative; ION-SELECTIVE ELECTRODES; MEMBRANE SENSOR; WATER SAMPLES; MILD-STEEL; COPPER; COMPLEXATION; PRECONCENTRATION; CU(II); ACID; ZINC;
D O I
10.29356/jmcs.v68i2.1884
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In the present study, initially, a thiourea derivative symmetric Schiff base, (1E,3E)-1,3-bis(5-bromo2-hydroxybenzylidene)thiourea, was synthesized and characterized by FTIR and SEM-EDX analysis. In addition, an all -solid-state composite Cu(II)-selective potentiometric sensor based on this synthesized compound as an electroactive substance was constructed. Optimization studies indicated that the composition of the optimum sensing composite exhibiting the best potentiometric characteristics was 3.0% Schiff base, 5.0 % multi -walled carbon nanotube (MWCNT), 20.0 % paraffin oil and 72.0% graphite by mass. The proposed sensor displayed a linear response in the concentration range of 5.0x10(-6)-1.0x10(-1) M with a slope of 31.1 mV/decade and a detection limit of 5.0x10(-7) M. The proposed sensor exhibited a fairly selective, stable (potential drift: 1.85 mV/h), and rapid (<10 s) response towards Cu(II) ions. Because of the magnitude of its potential drift, the sensor should be recalibrated along the analysis time at least half an hour apart. The sensor can employed safely in the samples with pHs in the range of 2.0-6.5. The lifetime of the fresh sensor surface was determined as 2 weeks. The most important advantage of the sensor is that the sensing composite surface is renewable (at least 10 times) and thus the sensor can be used many times for a long period of time. The analytical applications of the sensor were executed successfully by using the electrode in the potentiometric titration of Cu(II) ions with EDTA as an indicator electrode, in the direct determination of Cu(II) contents of spiked water samples, and in the determination of (w/w) Cu% content of a Turkish coin.
引用
收藏
页码:296 / 312
页数:17
相关论文
共 50 条
  • [11] Manganese (II) selective PVC based membrane sensor using a Schiff base
    Gupta, Vinod K.
    Jain, Ajay K.
    Maheshwari, Gaurav
    TALANTA, 2007, 72 (01) : 49 - 53
  • [12] Copper (II)-selective membrane electrodes based on Cu (II)-Schiff base complexes as an ionophore
    Tastekin, Mustafa
    Tunali, Filiz
    Atakol, Orhan
    Kilic, Esma
    REVIEWS IN ANALYTICAL CHEMISTRY, 2007, 26 (03) : 155 - 167
  • [13] Selective fluorescence sensor for Cu2+ with a novel triazole Schiff-base derivative with coumarin units
    Wang, Wei
    Yuan, Wen-Jing
    Liu, Qing-Lei
    Lei, Ya-Nan
    Qi, Shuai
    Gao, Yan
    HETEROCYCLIC COMMUNICATIONS, 2014, 20 (05) : 289 - 292
  • [14] Surface characterization of barium(II)-selective potentiometric sensor based on a newly synthesized derivative molecule
    Altunoluk, Onur C.
    Ozbek, Oguz
    Kalay, Erbay
    Tokali, Feyzi S.
    Aslan, Osman N.
    ELECTROANALYSIS, 2024, 36 (07)
  • [15] A highly sensitive and selective fluorescent sensor for the determination of copper(II) based on a schiff base
    Aksuner, Nur
    Henden, Emuer
    Yilmaz, Ibrahim
    Cukurovali, Alaaddin
    DYES AND PIGMENTS, 2009, 83 (02) : 211 - 217
  • [16] Nickel(II) Selective PVC-Based Membrane Sensor Using a Schiff Base
    Rezaei, B.
    Hadadzadeh, H.
    Azimi, A.
    INTERNATIONAL JOURNAL OF SPECTROSCOPY, 2011,
  • [17] Novel copper(II)-selective sensor based on a new hexadentates Schiff's base
    Ganjali, MR
    Emami, M
    Salavati-Niasari, M
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2002, 23 (10) : 1394 - 1398
  • [18] A novel colorimetric sensor based on a diarylethene derivative for selective detection of Cu(II)
    Cui, Shiqiang
    Pu, Shouzhi
    Dai, Yanfeng
    ANALYTICAL METHODS, 2015, 7 (08) : 3593 - 3599
  • [19] Development of an electrochemical sensor based on Schiff base for Cu(II) determination at nano level in river water and edible materials
    Singh, Ashok K.
    Jain, A. K.
    Singh, Jitendra
    Mehtab, Sameena
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2009, 89 (15) : 1081 - 1098
  • [20] A New Indole Substituted Biphenyldiamine Derivative Schiff Base: A New Sensor Application for the Selective Detection of Hg(II) Ions
    Kaya, S.
    RUSSIAN JOURNAL OF COORDINATION CHEMISTRY, 2021, 47 (12) : 903 - 908