A highly sensitive and selective fluorescent sensor for the determination of copper(II) based on a schiff base

被引:130
|
作者
Aksuner, Nur [1 ]
Henden, Emuer [1 ]
Yilmaz, Ibrahim [2 ]
Cukurovali, Alaaddin [2 ]
机构
[1] Univ Ege, Fac Sci, Dept Chem, TR-35100 Izmir, Turkey
[2] Firat Univ, Fac Arts & Sci, Dept Chem, TR-23169 Elazig, Turkey
关键词
Schiff base; PVC matrix; Fluorescence spectroscopy; Optical sensor; Copper(II); Fluorescence quenching; HEAVY-METAL IONS; OPTICAL SENSORS; BULK OPTODES; MEMBRANE; CU2+; COMPLEXES; DESIGN; LIGAND; MATRIX; LEAD;
D O I
10.1016/j.dyepig.2009.04.012
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A highly sensitive and selective optical sensor for the determination of trace amounts of Cu(2+) based on fluorescence quenching has been developed. The sensing membrane was prepared by immobilization of a novel fluorescent Schiff base ligand 4-(1-phenyl-1-metliylcyclobutane-3-yl)-2-(2-hydroxy-5-romobenzylidene)aminothiazole, on polyvinlyl chloride. The novel sensor, which has a linear range of 1.0 x 10(-8) - 5.7 x 10(-4) mol L(-1) for CU(2+) ions with a detection limit of 8.8 x 10(-9) mol L(-1) (0.56 mu g L(-1)), is fully reversible and the response time (tau(90)) was approximately 2.5 min. The optode was highly selective and can readily be regenerated by treatment with 10(-2) mol L(-1) HCL The accuracy of the proposed sensor was confirmed by analyzing standard reference materials of natural water and peach leaves. The sensor was successfully applied for the determination of copper in tap water and tea samples. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:211 / 217
页数:7
相关论文
共 50 条
  • [1] Highly sensitive and selective fluorescent sensor for copper(II) based on salicylaldehyde Schiff-base derivatives with aggregation induced emission and mechanoluminescence
    Yang, Xiaoli
    Zhang, Wenyan
    Yi, Zihan
    Xu, Hao
    Wei, Jun
    Hao, Lingyun
    [J]. NEW JOURNAL OF CHEMISTRY, 2017, 41 (19) : 11079 - 11088
  • [2] A Highly Selective and Sensitive Fluorescent Chemosensor for Aluminum Ions Based on Schiff Base
    Gao, Cunji
    Zang, Peixian
    Liu, Weisheng
    Tang, Yu
    [J]. JOURNAL OF FLUORESCENCE, 2016, 26 (06) : 2015 - 2021
  • [3] A Highly Selective and Sensitive Fluorescent Chemosensor for Aluminum Ions Based on Schiff Base
    Cunji Gao
    Peixian Zang
    Weisheng Liu
    Yu Tang
    [J]. Journal of Fluorescence, 2016, 26 : 2015 - 2021
  • [4] Copper(II) selective electrochemical sensor based on Schiff Base complexes
    Singh, LP
    Bhatnagar, JM
    [J]. TALANTA, 2004, 64 (02) : 313 - 319
  • [5] A highly sensitive and selective Schiff base fluorescent chemodosimeter for aluminum(III)
    Cheng, Xiao-Ying
    Wang, Ming-Fang
    Yang, Zheng-Yin
    Li, Yong
    Li, Tian-Rong
    Liu, Chun-Jiao
    Zhou, Qiao-Xia
    [J]. JOURNAL OF COORDINATION CHEMISTRY, 2013, 66 (11) : 1847 - 1853
  • [6] Highly selective and sensitive turn-on fluorescent sensor for detection of Al3+ based on quinoline-base Schiff base
    Wang, Yang
    Ma, Zhong-Ying
    Zhang, De-Long
    Deng, Jia-Li
    Chen, Xiong
    Xie, Cheng-Zhi
    Qiao, Xin
    Li, Qing-Zhong
    Xu, Jing-Yuan
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2018, 195 : 157 - 164
  • [7] A Zinc(II) Schiff Base Complex as Fluorescent Chemosensor for the Selective and Sensitive Detection of Copper(II) in Aqueous Solution
    Oliveri, Ivan Pietro
    Attina, Agostino
    Di Bella, Santo
    [J]. SENSORS, 2023, 23 (08)
  • [8] A Novel Highly Sensitive and Selective Fluorescent Sensor for Imaging Copper (II) in Living Cells
    Chen Zhou
    Yan Song
    Ning Xiao
    Yapeng Li
    Jiayuan Xu
    [J]. Journal of Fluorescence, 2014, 24 : 1331 - 1336
  • [9] A Novel Highly Sensitive and Selective Fluorescent Sensor for Imaging Copper (II) in Living Cells
    Zhou, Chen
    Song, Yan
    Xiao, Ning
    Li, Yapeng
    Xu, Jiayuan
    [J]. JOURNAL OF FLUORESCENCE, 2014, 24 (04) : 1331 - 1336
  • [10] Highly selective and sensitive copper membrane electrode based on a new synthesized Schiff base
    Gholivand, M. B.
    Rahimi-Nasrabadi, M.
    Ganjali, M. R.
    Salavati-Niasari, M.
    [J]. TALANTA, 2007, 73 (03) : 553 - 560