Development of a Composite Cu(II)-Selective Potentiometric Sensor Based on a Thiourea Derivative Symmetric Schiff Base

被引:2
|
作者
Yildirim, Ozden [1 ]
Coldur, Fatih [2 ]
Topcu, Cihan [3 ]
Caglar, Bulent [2 ]
机构
[1] Erzincan Binali Yildirim Univ, Grad Sch Nat & Appl Sci, TR-24100 Erzincan, Turkiye
[2] Erzincan Binali Yildirim Univ, Fac Arts & Sci, Dept Chem, TR-24100 Erzincan, Turkiye
[3] Samsun Univ, Fac Engn, Dept Biomed Engn, TR-55420 Samsun, Turkiye
关键词
Potentiometric sensor; copper(II)-selective electrode; all-solid-state sensor; copper(II) determination; Schiff base; thiourea derivative; ION-SELECTIVE ELECTRODES; MEMBRANE SENSOR; WATER SAMPLES; MILD-STEEL; COPPER; COMPLEXATION; PRECONCENTRATION; CU(II); ACID; ZINC;
D O I
10.29356/jmcs.v68i2.1884
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In the present study, initially, a thiourea derivative symmetric Schiff base, (1E,3E)-1,3-bis(5-bromo2-hydroxybenzylidene)thiourea, was synthesized and characterized by FTIR and SEM-EDX analysis. In addition, an all -solid-state composite Cu(II)-selective potentiometric sensor based on this synthesized compound as an electroactive substance was constructed. Optimization studies indicated that the composition of the optimum sensing composite exhibiting the best potentiometric characteristics was 3.0% Schiff base, 5.0 % multi -walled carbon nanotube (MWCNT), 20.0 % paraffin oil and 72.0% graphite by mass. The proposed sensor displayed a linear response in the concentration range of 5.0x10(-6)-1.0x10(-1) M with a slope of 31.1 mV/decade and a detection limit of 5.0x10(-7) M. The proposed sensor exhibited a fairly selective, stable (potential drift: 1.85 mV/h), and rapid (<10 s) response towards Cu(II) ions. Because of the magnitude of its potential drift, the sensor should be recalibrated along the analysis time at least half an hour apart. The sensor can employed safely in the samples with pHs in the range of 2.0-6.5. The lifetime of the fresh sensor surface was determined as 2 weeks. The most important advantage of the sensor is that the sensing composite surface is renewable (at least 10 times) and thus the sensor can be used many times for a long period of time. The analytical applications of the sensor were executed successfully by using the electrode in the potentiometric titration of Cu(II) ions with EDTA as an indicator electrode, in the direct determination of Cu(II) contents of spiked water samples, and in the determination of (w/w) Cu% content of a Turkish coin.
引用
收藏
页码:296 / 312
页数:17
相关论文
共 50 条
  • [41] Novel Schiff base iron(ii) phthalocyanine with composite MWCNTs on modified GCE: electrochemical sensor development for paracetamol
    Mounesh
    Reddy, K. R. Venugopala
    Yuvaraja, D.
    Manriquez, Juan M.
    Lokesh, K. S.
    Amshumali, M. K.
    REACTION CHEMISTRY & ENGINEERING, 2022, 7 (12) : 2550 - 2561
  • [42] A Schiff base functioning as a highly selective colorimetric sensor for Cu2+ion
    Kumar, Gujuluva Gangatharan Vinoth
    Arora, Pragya
    Draksharapu, Apparao
    MATERIALS LETTERS, 2024, 371
  • [43] POTENTIOMETRIC STUDY OF COMPLEXES OF CU(II), NI(II) AND CO(II) WITH SCHIFF-BASE DERIVED FROM SULFAPHENAZOLE AND SALICYLALDEHYDE
    JAIN, P
    CHATURVEDI, KK
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 1976, 53 (08) : 863 - 863
  • [44] Development of Potentiometric Lactate Biosensor Based on Composite pH Sensor
    Uygun, Hilmiye Deniz Ertugrul
    Tinkilic, Nihat
    Attar, Azade
    Isildak, Ibrahim
    JOURNAL OF NEW MATERIALS FOR ELECTROCHEMICAL SYSTEMS, 2016, 19 (03) : 151 - 156
  • [45] Potentiometric determination of Cu2+ ions in environmental samples using a newly developed Cu2+-selective electrode based on schiff base
    Kardas, Faruk
    Topcu, Cihan
    PAMUKKALE UNIVERSITY JOURNAL OF ENGINEERING SCIENCES-PAMUKKALE UNIVERSITESI MUHENDISLIK BILIMLERI DERGISI, 2018, 24 (07): : 1325 - 1331
  • [46] Potentiometric Ion-Selective Electrode Based on a New Single Crystal Cadmium(II) Schiff Base Complex for Detection of Fluoride Ion: Central Composite Design Optimization
    Biyareh, Mahdi Nejati
    Rezvani, Ali Reza
    Dashtian, Kheibar
    Montazerozohori, Morteza
    Ghaedi, Mehrorang
    Asl, Ardavan Masoudi
    White, Jonathan
    IEEE SENSORS JOURNAL, 2019, 19 (02) : 413 - 425
  • [47] PVC Membrane Potentiometric Sensor Based on a Schiff Base for Determination of Ho3+ ions
    Tamaddon, Atefeh
    Sadeghi, Hayedeh Bagheri
    Mollaei, Somayeh
    Ebrahimi, Arash Afshar
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2014, 6 (06): : 676 - 687
  • [48] Potentiometric Performance of Silver Ion-Selective Electrodes Based on Tridentate Schiff Base Derivatives
    Masato Ueda
    Takahiro Saito
    Keiichi Fujimori
    Takayo Moriuchi
    Yasuhiko Shibutani
    Analytical Sciences, 2004, 20 : 1649 - 1653
  • [49] Potentiometric performance of silver ion-selective electrodes based on tridentate Schiff base derivatives
    Ueda, M
    Saito, T
    Fujimori, K
    Moriuchi, T
    Shibutani, Y
    ANALYTICAL SCIENCES, 2004, 20 (12) : 1649 - 1653
  • [50] All-solid-State Potentiometric Cu(II)-selective Sensor Based on Ion Imprinted Methacrylamide Polymer
    Yolcu, Murat
    Dere, Nursen
    ELECTROANALYSIS, 2018, 30 (06) : 1147 - 1154