Development of a Composite Cu(II)-Selective Potentiometric Sensor Based on a Thiourea Derivative Symmetric Schiff Base

被引:2
|
作者
Yildirim, Ozden [1 ]
Coldur, Fatih [2 ]
Topcu, Cihan [3 ]
Caglar, Bulent [2 ]
机构
[1] Erzincan Binali Yildirim Univ, Grad Sch Nat & Appl Sci, TR-24100 Erzincan, Turkiye
[2] Erzincan Binali Yildirim Univ, Fac Arts & Sci, Dept Chem, TR-24100 Erzincan, Turkiye
[3] Samsun Univ, Fac Engn, Dept Biomed Engn, TR-55420 Samsun, Turkiye
关键词
Potentiometric sensor; copper(II)-selective electrode; all-solid-state sensor; copper(II) determination; Schiff base; thiourea derivative; ION-SELECTIVE ELECTRODES; MEMBRANE SENSOR; WATER SAMPLES; MILD-STEEL; COPPER; COMPLEXATION; PRECONCENTRATION; CU(II); ACID; ZINC;
D O I
10.29356/jmcs.v68i2.1884
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In the present study, initially, a thiourea derivative symmetric Schiff base, (1E,3E)-1,3-bis(5-bromo2-hydroxybenzylidene)thiourea, was synthesized and characterized by FTIR and SEM-EDX analysis. In addition, an all -solid-state composite Cu(II)-selective potentiometric sensor based on this synthesized compound as an electroactive substance was constructed. Optimization studies indicated that the composition of the optimum sensing composite exhibiting the best potentiometric characteristics was 3.0% Schiff base, 5.0 % multi -walled carbon nanotube (MWCNT), 20.0 % paraffin oil and 72.0% graphite by mass. The proposed sensor displayed a linear response in the concentration range of 5.0x10(-6)-1.0x10(-1) M with a slope of 31.1 mV/decade and a detection limit of 5.0x10(-7) M. The proposed sensor exhibited a fairly selective, stable (potential drift: 1.85 mV/h), and rapid (<10 s) response towards Cu(II) ions. Because of the magnitude of its potential drift, the sensor should be recalibrated along the analysis time at least half an hour apart. The sensor can employed safely in the samples with pHs in the range of 2.0-6.5. The lifetime of the fresh sensor surface was determined as 2 weeks. The most important advantage of the sensor is that the sensing composite surface is renewable (at least 10 times) and thus the sensor can be used many times for a long period of time. The analytical applications of the sensor were executed successfully by using the electrode in the potentiometric titration of Cu(II) ions with EDTA as an indicator electrode, in the direct determination of Cu(II) contents of spiked water samples, and in the determination of (w/w) Cu% content of a Turkish coin.
引用
收藏
页码:296 / 312
页数:17
相关论文
共 50 条
  • [31] EPR, DFT and electrochemical interpretation of a Cu(II) derivative incorporating a Schiff base precursor
    Das, Kuheli
    Goswami, Sanchita
    Beyene, Belete B.
    Yibeltal, Amogne W.
    Garribba, Eugenio
    Frontera, Antonio
    Datta, Amitabha
    POLYHEDRON, 2019, 159 : 323 - 329
  • [32] Adsorption of Cu(II) onto silica gel-immobilized Schiff base derivative
    Gubbuk, I. Hilal
    Gup, Ramazan
    Kara, Huseyin
    Ersoz, Mustafa
    DESALINATION, 2009, 249 (03) : 1243 - 1248
  • [33] Copper(II)-selective membrane electrode based on a recently synthesized naphthol-derivative Schiff’s base
    N. Alizadeh
    S. Ershad
    H. Naeimi
    H. Sharghi
    M. Shamsipur
    Fresenius' Journal of Analytical Chemistry, 1999, 365 : 511 - 515
  • [34] Copper(II)-selective membrane electrode based on a recently synthesized naphthol-derivative Schiff's base
    Alizadeh, N
    Ershad, S
    Naeimi, H
    Sharghi, H
    Shamsipur, M
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 365 (06): : 511 - 515
  • [35] Mercury(II) ion-selective polymeric membrane sensor based on a recently synthesized Schiff base
    Mashhadizadeh, MH
    Sheikhshoaie, I
    TALANTA, 2003, 60 (01) : 73 - 80
  • [36] Selective fluorescent sensor for mercury(II) ion based on an easy to prepare double naphthalene Schiff base
    Wei, Tai-bao
    Gao, Guo-ying
    Qu, Wen-juan
    Shi, Bing-bing
    Lin, Qi
    Yao, Hong
    Zhang, You-ming
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 199 : 142 - 147
  • [37] Fluorescence and Colorimetric Anion Sensor Based on Pyrrole Derivative as Its Schiff Base
    Liu Ge
    Shao Jie
    ACTA CHIMICA SINICA, 2011, 69 (09) : 1070 - 1074
  • [38] Selective Ratiometric Fluorescence Detection of Acetate Based on a Novel Schiff Base Derivative
    Liu, Ge
    Shao, Jie
    JOURNAL OF FLUORESCENCE, 2012, 22 (01) : 397 - 401
  • [39] A novel highly selective colorimetric sensor for aluminum (III) ion using Schiff base derivative
    Wang, Dong-Fang
    Ke, Ying-Chang
    Guo, Hong-Xu
    Chen, Jianhua
    Weng, Wen
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2014, 122 : 268 - 272
  • [40] Selective Ratiometric Fluorescence Detection of Acetate Based on a Novel Schiff Base Derivative
    Ge Liu
    Jie Shao
    Journal of Fluorescence, 2012, 22 : 397 - 401