Development of a Composite Cu(II)-Selective Potentiometric Sensor Based on a Thiourea Derivative Symmetric Schiff Base

被引:2
|
作者
Yildirim, Ozden [1 ]
Coldur, Fatih [2 ]
Topcu, Cihan [3 ]
Caglar, Bulent [2 ]
机构
[1] Erzincan Binali Yildirim Univ, Grad Sch Nat & Appl Sci, TR-24100 Erzincan, Turkiye
[2] Erzincan Binali Yildirim Univ, Fac Arts & Sci, Dept Chem, TR-24100 Erzincan, Turkiye
[3] Samsun Univ, Fac Engn, Dept Biomed Engn, TR-55420 Samsun, Turkiye
关键词
Potentiometric sensor; copper(II)-selective electrode; all-solid-state sensor; copper(II) determination; Schiff base; thiourea derivative; ION-SELECTIVE ELECTRODES; MEMBRANE SENSOR; WATER SAMPLES; MILD-STEEL; COPPER; COMPLEXATION; PRECONCENTRATION; CU(II); ACID; ZINC;
D O I
10.29356/jmcs.v68i2.1884
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In the present study, initially, a thiourea derivative symmetric Schiff base, (1E,3E)-1,3-bis(5-bromo2-hydroxybenzylidene)thiourea, was synthesized and characterized by FTIR and SEM-EDX analysis. In addition, an all -solid-state composite Cu(II)-selective potentiometric sensor based on this synthesized compound as an electroactive substance was constructed. Optimization studies indicated that the composition of the optimum sensing composite exhibiting the best potentiometric characteristics was 3.0% Schiff base, 5.0 % multi -walled carbon nanotube (MWCNT), 20.0 % paraffin oil and 72.0% graphite by mass. The proposed sensor displayed a linear response in the concentration range of 5.0x10(-6)-1.0x10(-1) M with a slope of 31.1 mV/decade and a detection limit of 5.0x10(-7) M. The proposed sensor exhibited a fairly selective, stable (potential drift: 1.85 mV/h), and rapid (<10 s) response towards Cu(II) ions. Because of the magnitude of its potential drift, the sensor should be recalibrated along the analysis time at least half an hour apart. The sensor can employed safely in the samples with pHs in the range of 2.0-6.5. The lifetime of the fresh sensor surface was determined as 2 weeks. The most important advantage of the sensor is that the sensing composite surface is renewable (at least 10 times) and thus the sensor can be used many times for a long period of time. The analytical applications of the sensor were executed successfully by using the electrode in the potentiometric titration of Cu(II) ions with EDTA as an indicator electrode, in the direct determination of Cu(II) contents of spiked water samples, and in the determination of (w/w) Cu% content of a Turkish coin.
引用
收藏
页码:296 / 312
页数:17
相关论文
共 50 条
  • [21] A New Indole Substituted Biphenyldiamine Derivative Schiff Base: A New Sensor Application for the Selective Detection of Hg(II) Ions
    S. Kaya
    Russian Journal of Coordination Chemistry, 2021, 47 : 903 - 908
  • [22] Thiocyanate: selective membrane electrode based on macrotricyclic binuclear Cu(II)–Schiff base complex
    Bhargav Patel
    Anish Kumar
    Shobhana K. Menon
    Journal of Inclusion Phenomena and Macrocyclic Chemistry, 2009, 64 : 239 - 247
  • [23] Thiocyanate: selective membrane electrode based on macrotricyclic binuclear Cu(II)-Schiff base complex
    Patel, Bhargav
    Kumar, Anish
    Menon, Shobhana K.
    JOURNAL OF INCLUSION PHENOMENA AND MACROCYCLIC CHEMISTRY, 2009, 64 (3-4) : 239 - 247
  • [24] A symmetric and selective fluorescent Cu (II) sensor based on bodipy and s-triazine
    Kursunlu, Ahmed Nuri
    Koc, Ziya Erdem
    Obali, Aslihan Yilmaz
    Guler, Ersin
    JOURNAL OF LUMINESCENCE, 2014, 149 : 215 - 220
  • [25] A novel, highly sensitive, selective, reversible and turn-on chemi-sensor based on Schiff base for rapid detection of Cu(II)
    Saleh, Sayed M.
    Ali, Reham
    Ali, Ibrahim A. I.
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2017, 183 : 225 - 231
  • [26] The use of thiazole derivative molecules as sensor materials: Potentiometric determination of Cu(II) ions
    Oren, Serkan
    Ozbek, Oguz
    Isildak, Omer
    VIETNAM JOURNAL OF CHEMISTRY, 2024, 62 (04) : 486 - 492
  • [27] Selective and sensitive lead (II) solid-contact potentiometric sensor based on naphthalene-sulfonamide derivative
    A. Kamal
    R. Tejpal
    V. Bhalla
    M. Kumar
    R. K. Mahajan
    International Journal of Environmental Science and Technology, 2015, 12 : 2567 - 2578
  • [28] Selective and sensitive lead (II) solid-contact potentiometric sensor based on naphthalene-sulfonamide derivative
    Kamal, A.
    Tejpal, R.
    Bhalla, V.
    Kumar, M.
    Mahajan, R. K.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2015, 12 (08) : 2567 - 2578
  • [29] A new nano-composite electrode as a copper (II) selective potentiometric sensor
    Afkhami, Abbas
    Khoshsafar, Hosein
    Madrakian, Tayyebeh
    Shirzadmehr, Ali
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2014, 11 (05) : 1373 - 1380
  • [30] A new nano-composite electrode as a copper (II) selective potentiometric sensor
    Abbas Afkhami
    Hosein Khoshsafar
    Tayyebeh Madrakian
    Ali Shirzadmehr
    Journal of the Iranian Chemical Society, 2014, 11 : 1373 - 1380