Development of a Composite Cu(II)-Selective Potentiometric Sensor Based on a Thiourea Derivative Symmetric Schiff Base

被引:2
|
作者
Yildirim, Ozden [1 ]
Coldur, Fatih [2 ]
Topcu, Cihan [3 ]
Caglar, Bulent [2 ]
机构
[1] Erzincan Binali Yildirim Univ, Grad Sch Nat & Appl Sci, TR-24100 Erzincan, Turkiye
[2] Erzincan Binali Yildirim Univ, Fac Arts & Sci, Dept Chem, TR-24100 Erzincan, Turkiye
[3] Samsun Univ, Fac Engn, Dept Biomed Engn, TR-55420 Samsun, Turkiye
关键词
Potentiometric sensor; copper(II)-selective electrode; all-solid-state sensor; copper(II) determination; Schiff base; thiourea derivative; ION-SELECTIVE ELECTRODES; MEMBRANE SENSOR; WATER SAMPLES; MILD-STEEL; COPPER; COMPLEXATION; PRECONCENTRATION; CU(II); ACID; ZINC;
D O I
10.29356/jmcs.v68i2.1884
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In the present study, initially, a thiourea derivative symmetric Schiff base, (1E,3E)-1,3-bis(5-bromo2-hydroxybenzylidene)thiourea, was synthesized and characterized by FTIR and SEM-EDX analysis. In addition, an all -solid-state composite Cu(II)-selective potentiometric sensor based on this synthesized compound as an electroactive substance was constructed. Optimization studies indicated that the composition of the optimum sensing composite exhibiting the best potentiometric characteristics was 3.0% Schiff base, 5.0 % multi -walled carbon nanotube (MWCNT), 20.0 % paraffin oil and 72.0% graphite by mass. The proposed sensor displayed a linear response in the concentration range of 5.0x10(-6)-1.0x10(-1) M with a slope of 31.1 mV/decade and a detection limit of 5.0x10(-7) M. The proposed sensor exhibited a fairly selective, stable (potential drift: 1.85 mV/h), and rapid (<10 s) response towards Cu(II) ions. Because of the magnitude of its potential drift, the sensor should be recalibrated along the analysis time at least half an hour apart. The sensor can employed safely in the samples with pHs in the range of 2.0-6.5. The lifetime of the fresh sensor surface was determined as 2 weeks. The most important advantage of the sensor is that the sensing composite surface is renewable (at least 10 times) and thus the sensor can be used many times for a long period of time. The analytical applications of the sensor were executed successfully by using the electrode in the potentiometric titration of Cu(II) ions with EDTA as an indicator electrode, in the direct determination of Cu(II) contents of spiked water samples, and in the determination of (w/w) Cu% content of a Turkish coin.
引用
收藏
页码:296 / 312
页数:17
相关论文
共 50 条
  • [1] A chloride ion-selective potentiometric sensor based on a polymeric schiff base complex
    Kumar, KG
    John, KS
    Indira, CJ
    INDIAN JOURNAL OF CHEMICAL TECHNOLOGY, 2006, 13 (01) : 13 - 16
  • [2] Copper(II) selective electrochemical sensor based on Schiff Base complexes
    Singh, LP
    Bhatnagar, JM
    TALANTA, 2004, 64 (02) : 313 - 319
  • [3] Nickel(II)-selective membrane potentiometric sensor using a recently synthesized Schiff base as neutral carrier
    Mashhadizadeh, MH
    Sheikhshoaie, I
    Saeid-Nia, S
    SENSORS AND ACTUATORS B-CHEMICAL, 2003, 94 (03) : 241 - 246
  • [4] Synthesis of a Novel Fluorescent Schiff Base as a Possible Cu(II) Ion Selective Sensor
    Yildirim, Mehmet
    Kaya, Ismet
    JOURNAL OF FLUORESCENCE, 2010, 20 (03) : 771 - 777
  • [5] Synthesis of a Novel Fluorescent Schiff Base as a Possible Cu(II) Ion Selective Sensor
    Mehmet Yıldırım
    İsmet Kaya
    Journal of Fluorescence, 2010, 20 : 771 - 777
  • [6] A potentiometric sensor of silver ions based on the Schiff base of diphenol
    Lee, Eunhee
    Jeong, Eunseon
    Jeon, Seungwon
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (08) : 2591 - 2596
  • [7] A potentiometric sensor of silver ions based on the Schiff base of diphenol
    Eunhee Lee
    Eunseon Jeong
    Seungwon Jeon
    Journal of Solid State Electrochemistry, 2012, 16 : 2591 - 2596
  • [8] Lead(II)-Selective Potentiometric Sensor Based on Schiff Base of Thiophene-2-Aldehyde Thiosemicarbazone (TATS) in PVC Matrix
    Mohan, Chandra
    Sharma, Kusum
    Chandra, Sulekh
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2022, 14 (09): : 860 - 870
  • [9] Coated, wire-based, new Schiff base potentiometric sensor for lead(II) ion
    Mazloum-Ardakany, M
    Ensafi, AA
    Naeimi, H
    Dastanpour, A
    Shamlli, A
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2003, 39 (03) : 269 - 273
  • [10] Coated, Wire-Based, New Schiff Base Potentiometric Sensor for Lead(II) Ion
    M. Mazlum Ardakany
    A. A. Ensafi
    H. Naeimi
    A. Dastanpour
    A. Shamlli
    Russian Journal of Electrochemistry, 2003, 39 : 269 - 273