Coated, Wire-Based, New Schiff Base Potentiometric Sensor for Lead(II) Ion

被引:0
|
作者
M. Mazlum Ardakany
A. A. Ensafi
H. Naeimi
A. Dastanpour
A. Shamlli
机构
[1] Kashan University,Department of Chemistry
[2] Isfahan University of Technology,College of Chemistry
来源
关键词
Chloride; Methane; Wastewater; Titration; Response Time;
D O I
暂无
中图分类号
学科分类号
摘要
An ion-selective electrode for lead(II) based on a dispersion of N,N"-bis(3-methyl salicylidine)-p-phenyl methane diamine particles into a polymeric membrane using coated-wire configuration is described. Membranes based on polyvinyl chloride containing different amounts of plasticizer and ionophore are studied. The best performance in terms of slope (30.3 ± 0.6 mV per decade) and response time (<15 s) is displayed. The sensor shows a Nernstian response for Pb(II) ions over a wide concentration range of 2.0 × 10–5 to 0.10 M. The sensors can be used for more than three months without any considerable divergence in potentials. The selectivity is also good towards the most common univalent and divalent cations and the signal is constant in the pH range 1.6–6.0. An application to lead determination in mineral rocks and wastewater proved to be a success, and it was employed as an indicator electrode in potentiometric titration of CrO2–4 with lead ions.
引用
收藏
页码:269 / 273
页数:4
相关论文
共 50 条
  • [1] Coated, wire-based, new Schiff base potentiometric sensor for lead(II) ion
    Mazloum-Ardakany, M
    Ensafi, AA
    Naeimi, H
    Dastanpour, A
    Shamlli, A
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2003, 39 (03) : 269 - 273
  • [2] Highly selective lead(II) coated-wire electrode based on a new Schiff base
    Mazloum-Ardakani, M
    Ensafi, AA
    Naeimi, H
    Dastanpour, A
    Shamlli, A
    SENSORS AND ACTUATORS B-CHEMICAL, 2003, 96 (1-2) : 441 - 445
  • [3] Coated wire lead(II)-selective electrode based on a Schiff base ionophore for low concentration measurements
    Ahmad Soleymanpour
    Bita Shafaatian
    Kamallodin Kor
    Ali Reza Hasaninejad
    Monatshefte für Chemie - Chemical Monthly, 2012, 143 : 181 - 188
  • [4] Coated wire lead(II)-selective electrode based on a Schiff base ionophore for low concentration measurements
    Soleymanpour, Ahmad
    Shafaatian, Bita
    Kor, Kamallodin
    Hasaninejad, Ali Reza
    MONATSHEFTE FUR CHEMIE, 2012, 143 (02): : 181 - 188
  • [5] Coated wire lead(II) selective potentiometric sensor based on 4-tert-butylcalix[6]arene
    Bhat, VS
    Ijeri, VS
    Srivastava, AK
    SENSORS AND ACTUATORS B-CHEMICAL, 2004, 99 (01) : 98 - 105
  • [6] A chloride ion-selective potentiometric sensor based on a polymeric schiff base complex
    Kumar, KG
    John, KS
    Indira, CJ
    INDIAN JOURNAL OF CHEMICAL TECHNOLOGY, 2006, 13 (01) : 13 - 16
  • [7] Lead(II)-Selective Potentiometric Sensor Based on Schiff Base of Thiophene-2-Aldehyde Thiosemicarbazone (TATS) in PVC Matrix
    Mohan, Chandra
    Sharma, Kusum
    Chandra, Sulekh
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2022, 14 (09): : 860 - 870
  • [8] A potentiometric sensor of silver ions based on the Schiff base of diphenol
    Lee, Eunhee
    Jeong, Eunseon
    Jeon, Seungwon
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (08) : 2591 - 2596
  • [9] A potentiometric sensor of silver ions based on the Schiff base of diphenol
    Eunhee Lee
    Eunseon Jeong
    Seungwon Jeon
    Journal of Solid State Electrochemistry, 2012, 16 : 2591 - 2596
  • [10] Potentiometric Sensor for the Determination of Lead(II) Ion Based on Zirconium(IV) Iodosulphosalicylate
    Lutfullah
    Rashid, Mohd
    Rahman, Nafisur
    SCIENCE OF ADVANCED MATERIALS, 2012, 4 (12) : 1232 - 1237