Coated, Wire-Based, New Schiff Base Potentiometric Sensor for Lead(II) Ion

被引:0
|
作者
M. Mazlum Ardakany
A. A. Ensafi
H. Naeimi
A. Dastanpour
A. Shamlli
机构
[1] Kashan University,Department of Chemistry
[2] Isfahan University of Technology,College of Chemistry
来源
关键词
Chloride; Methane; Wastewater; Titration; Response Time;
D O I
暂无
中图分类号
学科分类号
摘要
An ion-selective electrode for lead(II) based on a dispersion of N,N"-bis(3-methyl salicylidine)-p-phenyl methane diamine particles into a polymeric membrane using coated-wire configuration is described. Membranes based on polyvinyl chloride containing different amounts of plasticizer and ionophore are studied. The best performance in terms of slope (30.3 ± 0.6 mV per decade) and response time (<15 s) is displayed. The sensor shows a Nernstian response for Pb(II) ions over a wide concentration range of 2.0 × 10–5 to 0.10 M. The sensors can be used for more than three months without any considerable divergence in potentials. The selectivity is also good towards the most common univalent and divalent cations and the signal is constant in the pH range 1.6–6.0. An application to lead determination in mineral rocks and wastewater proved to be a success, and it was employed as an indicator electrode in potentiometric titration of CrO2–4 with lead ions.
引用
收藏
页码:269 / 273
页数:4
相关论文
共 50 条
  • [41] Synthesis of a Novel Fluorescent Schiff Base as a Possible Cu(II) Ion Selective Sensor
    Mehmet Yıldırım
    İsmet Kaya
    Journal of Fluorescence, 2010, 20 : 771 - 777
  • [42] A novel Schiff-base as a Cu(II) ion fluorescent sensor in aqueous solution
    Gunduz, Z. Yurtman
    Gunduz, C.
    Ozpinar, C.
    Urucu, O. Aydin
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2015, 136 : 1679 - 1683
  • [43] Thermal studies of new lead(II) coated-wire membrane electrodes
    Shoukry, AF
    Shuaib, NM
    Ibrahim, YA
    Malhas, RN
    ELECTROANALYSIS, 2005, 17 (08) : 713 - 718
  • [44] A lead (II) selective PVC membrane potentiometric sensor based on a tetraazamacrocyclic ligand
    Mathew, Sobhana
    Rajith, Leena
    Lonappan, Laina Angamaly
    Jos, Theresa
    Kumar, Krishnapillai Girish
    JOURNAL OF INCLUSION PHENOMENA AND MACROCYCLIC CHEMISTRY, 2014, 78 (1-4) : 171 - 177
  • [45] A lead (II) selective PVC membrane potentiometric sensor based on a tetraazamacrocyclic ligand
    Sobhana Mathew
    Leena Rajith
    Laina Angamaly Lonappan
    Theresa Jos
    Krishnapillai Girish Kumar
    Journal of Inclusion Phenomena and Macrocyclic Chemistry, 2014, 78 : 171 - 177
  • [46] PVC-based Cu(II)-Schiff base complex membrane coated graphite electrode for the determination of the triiodide ion
    Sadeghi, S.
    Gafarzadeh, A.
    Naeimi, H.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 61 (07) : 677 - 682
  • [47] PVC-based Cu (II)-Schiff base complex membrane coated graphite electrode for the determination of the triiodide ion
    S. Sadeghi
    A. Gafarzadeh
    H. Naeimi
    Journal of Analytical Chemistry, 2006, 61 : 677 - 682
  • [48] Synthesis and characterization of novel nano-chitosan Schiff base and use of lead (II) sensor
    Kocak, Nuriye
    Sahin, Mustafa
    Kucukkolbasi, Semahat
    Erdogan, Zehra Ozden
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2012, 51 (05) : 1159 - 1166
  • [49] Potentiometric Study of a New Schiff Base and its Metal Ion Complexes: Preparation, Characterization and Biological Activity
    Al-Saidi, Hamed M.
    Gouda, Gamal A.
    Farghaly, O. A.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (11): : 10785 - 10801
  • [50] Manganese (II) selective PVC based membrane sensor using a Schiff base
    Gupta, Vinod K.
    Jain, Ajay K.
    Maheshwari, Gaurav
    TALANTA, 2007, 72 (01) : 49 - 53