Coated, Wire-Based, New Schiff Base Potentiometric Sensor for Lead(II) Ion

被引:0
|
作者
M. Mazlum Ardakany
A. A. Ensafi
H. Naeimi
A. Dastanpour
A. Shamlli
机构
[1] Kashan University,Department of Chemistry
[2] Isfahan University of Technology,College of Chemistry
来源
关键词
Chloride; Methane; Wastewater; Titration; Response Time;
D O I
暂无
中图分类号
学科分类号
摘要
An ion-selective electrode for lead(II) based on a dispersion of N,N"-bis(3-methyl salicylidine)-p-phenyl methane diamine particles into a polymeric membrane using coated-wire configuration is described. Membranes based on polyvinyl chloride containing different amounts of plasticizer and ionophore are studied. The best performance in terms of slope (30.3 ± 0.6 mV per decade) and response time (<15 s) is displayed. The sensor shows a Nernstian response for Pb(II) ions over a wide concentration range of 2.0 × 10–5 to 0.10 M. The sensors can be used for more than three months without any considerable divergence in potentials. The selectivity is also good towards the most common univalent and divalent cations and the signal is constant in the pH range 1.6–6.0. An application to lead determination in mineral rocks and wastewater proved to be a success, and it was employed as an indicator electrode in potentiometric titration of CrO2–4 with lead ions.
引用
收藏
页码:269 / 273
页数:4
相关论文
共 50 条
  • [21] Potentiometric Ion-Selective Electrode Based on a New Single Crystal Cadmium(II) Schiff Base Complex for Detection of Fluoride Ion: Central Composite Design Optimization
    Biyareh, Mahdi Nejati
    Rezvani, Ali Reza
    Dashtian, Kheibar
    Montazerozohori, Morteza
    Ghaedi, Mehrorang
    Asl, Ardavan Masoudi
    White, Jonathan
    IEEE SENSORS JOURNAL, 2019, 19 (02) : 413 - 425
  • [22] Perchlorate Ion Sensor of PVC Membrane Based on Ni(II) Complex with Hexadentate-schiff Base
    Shibutani, Yasuhiko
    Matsubayashi, Tooru
    Fujimori, Keiichi
    Moriuchi-Kawakami, Takayo
    BUNSEKI KAGAKU, 2012, 61 (03) : 251 - 255
  • [23] Mercury(II) ion-selective polymeric membrane sensor based on a recently synthesized Schiff base
    Mashhadizadeh, MH
    Sheikhshoaie, I
    TALANTA, 2003, 60 (01) : 73 - 80
  • [24] Selective fluorescent sensor for mercury(II) ion based on an easy to prepare double naphthalene Schiff base
    Wei, Tai-bao
    Gao, Guo-ying
    Qu, Wen-juan
    Shi, Bing-bing
    Lin, Qi
    Yao, Hong
    Zhang, You-ming
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 199 : 142 - 147
  • [25] Some Schiff base complexes of lead(II)
    Parr, J
    Ross, AT
    Slawin, AMZ
    JOURNAL OF THE CHEMICAL SOCIETY-DALTON TRANSACTIONS, 1996, (08): : 1509 - 1512
  • [26] Nickel(II)-selective membrane potentiometric sensor using a recently synthesized Schiff base as neutral carrier
    Mashhadizadeh, MH
    Sheikhshoaie, I
    Saeid-Nia, S
    SENSORS AND ACTUATORS B-CHEMICAL, 2003, 94 (03) : 241 - 246
  • [27] Novel coated wire potentiometric sensor for selective determination of Mn(II) ions in various authentic samples
    Aglan, Refaat F.
    Mahmoud, Hazem H.
    Rashad, Ahmed M.
    Saleh, Hosam M.
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2021, 18 (07) : 1567 - 1579
  • [28] Novel coated wire potentiometric sensor for selective determination of Mn(II) ions in various authentic samples
    Refaat F. Aglan
    Hazem H. Mahmoud
    Ahmed M. Rashad
    Hosam M. Saleh
    Journal of the Iranian Chemical Society, 2021, 18 : 1567 - 1579
  • [29] PVC Membrane Potentiometric Sensor Based on a Schiff Base for Determination of Ho3+ ions
    Tamaddon, Atefeh
    Sadeghi, Hayedeh Bagheri
    Mollaei, Somayeh
    Ebrahimi, Arash Afshar
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2014, 6 (06): : 676 - 687
  • [30] Design and Characterization of Electrochemical Sensor for the Determination of Mercury(II) Ion in Real Samples Based upon a New Schiff Base Derivative as an Ionophore
    Alharthi, Salman S.
    Fallatah, Ahmed M.
    Al-Saidi, Hamed M.
    SENSORS, 2021, 21 (09)