An ion-selective electrode for lead(II) based on a dispersion of N,N"-bis(3-methyl salicylidine)-p-phenyl methane diamine particles into a polymeric membrane using coated-wire configuration is described. Membranes based on polyvinyl chloride containing different amounts of plasticizer and ionophore are studied. The best performance in terms of slope (30.3 ± 0.6 mV per decade) and response time (<15 s) is displayed. The sensor shows a Nernstian response for Pb(II) ions over a wide concentration range of 2.0 × 10–5 to 0.10 M. The sensors can be used for more than three months without any considerable divergence in potentials. The selectivity is also good towards the most common univalent and divalent cations and the signal is constant in the pH range 1.6–6.0. An application to lead determination in mineral rocks and wastewater proved to be a success, and it was employed as an indicator electrode in potentiometric titration of CrO2–4 with lead ions.
引用
收藏
页码:269 / 273
页数:4
相关论文
共 50 条
  • [31] Copper (II) ion selective liquid membrane electrode based on new Schiff base carrier
    Sadeghi, S
    Vardini, MT
    Naeimi, H
    ANNALI DI CHIMICA, 2006, 96 (1-2) : 65 - 74
  • [32] Copper(II) selective electrochemical sensor based on Schiff Base complexes
    Singh, LP
    Bhatnagar, JM
    TALANTA, 2004, 64 (02) : 313 - 319
  • [33] Potentiometric Performance of Silver Ion-Selective Electrodes Based on Tridentate Schiff Base Derivatives
    Masato Ueda
    Takahiro Saito
    Keiichi Fujimori
    Takayo Moriuchi
    Yasuhiko Shibutani
    Analytical Sciences, 2004, 20 : 1649 - 1653
  • [34] Potentiometric performance of silver ion-selective electrodes based on tridentate Schiff base derivatives
    Ueda, M
    Saito, T
    Fujimori, K
    Moriuchi, T
    Shibutani, Y
    ANALYTICAL SCIENCES, 2004, 20 (12) : 1649 - 1653
  • [35] New solid-state membrane and coated wire potentiometric sensors for the determination of Zn(II) ions based on nanoparticles
    Mohamed A. F. Elmosallamy
    Hassan A. Hashem
    Fatma F. Abdalmoez
    Analytical and Bioanalytical Chemistry, 2022, 414 : 8277 - 8287
  • [36] New solid-state membrane and coated wire potentiometric sensors for the determination of Zn(II) ions based on nanoparticles
    Elmosallamy, Mohamed A. F.
    Hashem, Hassan A.
    Abdalmoez, Fatma F.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (29-30) : 8277 - 8287
  • [37] A New Schiff's Base Fluorescent Sensor for the Selective Detection of Mercury Ion
    Wang, Xuemei
    Yan, Hua
    Chen, Yong
    Bao, Hebin
    ADVANCED MATERIALS, PTS 1-4, 2011, 239-242 : 1105 - +
  • [38] Synthesis of a Novel Fluorescent Schiff Base as a Possible Cu(II) Ion Selective Sensor
    Yildirim, Mehmet
    Kaya, Ismet
    JOURNAL OF FLUORESCENCE, 2010, 20 (03) : 771 - 777
  • [39] Highly Selective Ratiometric Fluorescent Sensor for La(III) Ion Based on a New Schiff's Base
    Hosseini, Morteza
    Ganjali, Mohammad Reza
    Veismohammadi, Bahareh
    Riahl, Siavash
    Norouzi, Parviz
    Salavati-Niasari, Masoud
    Abkenar, Shiva Dehghan
    ANALYTICAL LETTERS, 2009, 42 (07) : 1029 - 1040
  • [40] A cobalt (II) complex based on antipyrine derived schiff base as colorimetric sensor for Fe3+ ion
    Zhang, Xiao-Yong
    Ma, Xue-Lin
    Gao, Jun-Fang
    Wang, Mei-Rong
    Zhang, Yu-Heng
    Yong, Sheng-Li
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2022, 99 (04)