Double-Tuned Birdcage Radio Frequency Coil for 7 T MRI: Optimization, Construction and Workbench Validation

被引:0
|
作者
Retico, Alessandra [1 ]
Maggiorelli, Francesca [1 ,2 ,3 ]
Giovannetti, Giulio [4 ]
Boskamp, Eddy [5 ]
Robb, Fraser [6 ]
Fantasia, Marco [7 ]
Galante, Angelo [7 ,8 ,9 ]
Alecci, Marcello [7 ,8 ,9 ]
Tiberi, Gianluigi [10 ,11 ]
Tosetti, Michela [3 ,12 ]
机构
[1] Natl Inst Nucl Phys INFN, Pisa Div, I-56127 Pisa, Italy
[2] Univ Siena, Dept Phys Sci Earth & Environm DSFTA, I-53100 Siena, Italy
[3] Imago7 Fdn, I-56128 Pisa, Italy
[4] Natl Res Council CNR, Inst Clin Physiol, I-56124 Pisa, Italy
[5] Hyperfine Res Inc, Guilford, CT 06437 USA
[6] GE Healthcare Inc, Aurora, OH 44202 USA
[7] Univ Aquila, Dept Life Hlth & Environm Sci MESVA, I-67100 Laquila, Italy
[8] INFN, Gran Sasso Natl Lab, I-67100 Laquila, Italy
[9] Univ Aquila, CNR, SPIN, Dept Phys & Chem Sci, I-67100 Laquila, Italy
[10] London South Bank Univ, Sch Engn, London SE1 0AA, England
[11] Umbria Bioengn Technol UBT Srl, I-06081 Perugia, Italy
[12] IRCCS Stella Maris Fdn, I-56128 Pisa, Italy
关键词
UHF MRI; 7 T MRI; RF coils; double tuned; sodium imaging; TISSUE SODIUM CONCENTRATION; HUMAN BRAIN; MYOCARDIAL-INFARCTION; NA-23; MRI; QUADRATURE; DESIGN; SPECTROSCOPY; MUSCLE; PERFORMANCE; VIABILITY;
D O I
10.3390/electronics12040901
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The aim of the present study is the optimization, construction, and workbench validation of a double-tuned H-1- Na-23 volume radio frequency (RF) coil suitable for human head imaging at 7 T, based on the birdcage geometry. The birdcage-like design which is considered is the four-ring model, in which two standard birdcage-like structures with the same diameters are nested along the longitudinal axis. Simulations based on Maxwell's equations are performed to evaluate the RF magnetic field homogeneity and the RF coil efficiency varying the coil geometrical parameters. The RF magnetic field homogeneity is evaluated both on the transverse (z = 0) and longitudinal (y = 0) planes without performing the impedance matching procedure, so that the RF coil symmetry is not perturbed by the matching network. The RF coil efficiency is instead dependent on the effective coil input RF power, and it is evaluated after matching the coil, so that the reflected power is minimized, assuming that the stimulation power is totally delivered to the RF coil. Considering the simulation results and the target application, the useful RF coil geometrical parameters are fixed. The four-ring model, which showed the best performances, has been built and tested on a workbench, using a cylindrical phantom filled with a 0.05 M saline solution as load. This provides the first example of a four-ring realization intended H-1- Na-23 for human head imaging at 7 T.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Double-tuned four-ring birdcage resonators forin vivo31P-nuclear magnetic resonance spectroscopy at 11.75 T
    T. Lanz
    M. von Kienlin
    W. Behr
    A. Haase
    Magnetic Resonance Materials in Physics, Biology and Medicine, 1997, 5 : 243 - 246
  • [22] Double-frequency birdcage volume coils for 4.7T and 7T
    Tomanek, B
    Volotovskyy, V
    Gruwel, MLH
    McKenzie, E
    King, SB
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2005, 26B (01) : 16 - 22
  • [23] Design and Construction of a PET-Compatible Double-Tuned 1H/31P MR Head Coil
    Celik, A. Avdo
    Choi, Chang-Hoon
    Tellmann, Lutz
    Rick, Claire
    Shah, N. Jon
    Felder, Joerg
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (08) : 2015 - 2022
  • [24] Design and construction of a novel 1H/19F double-tuned coil system using PIN-diode switches at 9.4 T
    Choi, Chang-Hoon
    Hong, Suk-Min
    Ha, YongHyun
    Shah, N. Jon
    JOURNAL OF MAGNETIC RESONANCE, 2017, 279 : 11 - 15
  • [25] A double-tuned 1H/31P coil for rabbit heart metabolism detection at 3 T
    Quan, Zhiyan
    Yang, Zhaoxia
    Tang, Xiaocui
    Fu, Caixia
    Zhou, Xiaoyue
    Huang, Lu
    Xia, Liming
    Zhang, Xiaotong
    NMR IN BIOMEDICINE, 2024, 37 (02)
  • [26] A dual 1H/19F birdcage coil for small animals at 7 T MRI
    Palmira Villa-Valverde
    Ignacio Rodríguez
    Daniel Padró
    Marina Benito
    Carlos Ernesto Garrido-Salmon
    Jesús Ruiz-Cabello
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2019, 32 : 79 - 87
  • [27] Double-layered dual-tuned RF coil using frequency-selectable PIN-diode control at 7-T MRI
    Han, Sang-Doc
    Heo, Phil
    Kim, Han-Joong
    Song, Hyunwoo
    Kim, Donghyuk
    Seo, Jeung-Hoon
    Ryu, Yeunchul
    Noh, Young
    Kim, Kyoung-Nam
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2017, 47B (04)
  • [28] Birdcage Coil with Inductively Coupled RF Coil Array for Improving |B1| -Field Sensitivity In 7-T MRI
    Byun, Jong-Deok
    Seo, Jeung-Hoon
    Kang, Taewon
    Ryu, Yeunchul
    Kim, Kyoung-Nam
    JOURNAL OF MAGNETICS, 2017, 22 (03) : 378 - 381
  • [29] A dual 1H/19F birdcage coil for small animals at 7T MRI
    Villa-Valverde, Palmira
    Rodriguez, Ignacio
    Padro, Daniel
    Benito, Marina
    Garrido-Salmon, Carlos Ernesto
    Ruiz-Cabello, Jesus
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2019, 32 (01) : 79 - 87
  • [30] Practical design of a 4 Tesla double-tuned RF surface coil for interleaved 1H and 23Na MRI of rat brain
    Alecci, M.
    Romanzetti, S.
    Kaffanke, J.
    Celik, A.
    Wegener, H. P.
    Shah, N. J.
    JOURNAL OF MAGNETIC RESONANCE, 2006, 181 (02) : 203 - 211